1. BEFORE YOU BEGIN 

Unpacking Instructions 

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are 
present and have been received in good condition. Notify the freight company immediately and retain packing 
material for inspection if any parts appear to be damaged from shipping or the carton itself shows signs of 
mishandling. Keep the carton and all packing materials. In the event that a fixture must be returned to the factory, it 
is important that the fixture be returned in the original factory box and packing. 

 

Safety Instructions

 

Please read these instructions carefully, they include important information about the installation, usage and 
maintenance of this product. 
• Please keep this User Guide for future reference. If you sell the unit to another user, be sure that he also receives 
this instruction booklet. 
• Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is 
not higher than that stated on the bottom of the fixture. 
• This product is intended for indoor use only! 
• To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable 
materials close to the unit while operating. 
• The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be 
sure that no ventilation slots are blocked. 
• Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse size 
and type. 
• Maximum ambient temperature (Ta) is 104° F (40°C).  Do not operate the fixture at temperatures higher than this. 
• In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by 
yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest 
authorized technical assistance center. Always use the same type of spare parts. 
• Don’t connect the device to a dimmer pack. 
• Make sure the power cord is never crimped or damaged. 
• Never disconnect the power cord by pulling or tugging on the cord. 
• Avoid direct eye exposure to the light source while it is on. 

 
Installation 

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid 
vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure 
and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times 
of the weight of the unit when installing the fixture. 
The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people 
and has no one pass by or under it. 
 

Operation 

The unit can be operated by DMX512 control or used as an individual unit without controller. 
Several units can be linked together to operate in master/slave mode and perform the built-in programmed lighting 
shows triggered by music. Please use a 3 pin XLR cable/plug when connecting them together. 
• Fan cooled. 

GB 

Summary of Contents for LED-FLOWER

Page 1: ...pas tre mis au rebut avec les ordures m nag res Veuillez les faire recycler l o il existe des centres pour cela Consultez les autorit s locales ou votre revendeur sur la fa on de les recycler NOTA IM...

Page 2: ...s disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse size and type Maximum ambient temperature Ta is 104 F 40 C Do not operate the fixture at tempera...

Page 3: ...ngs below Master unit when working at Auto run or Sound Control mode operation Slave units DMX start address MUST be set to d001 LED display as below DMX code setting D001 D512 CH1 LED Dimmer 0 255 CH...

Page 4: ...surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every...

Page 5: ...temp ratures sup rieures En cas de dysfonctionnement arr tez imm diatement l appareil N essayez jamais de r parer l appareil par vous m me Une r paration mal faite peut entra ner des dommages et des d...

Page 6: ...ge du code DMX D001 D512 CH1 Dimmer LED 0 255 CH2 Flash 0 255 CH3 Moteur gobo 0 255 CH4 Moteur miroir 0 255 CH5 DMX Auto 11 200 DMX command par la musique 201 255 R glage manuel A1 Mode R glage automa...

Page 7: ...MX512 Automatique activation par le son Ma tre esclave Dimensions 310 X 250 X 200mm Poids 2 4 kg Auspacken Sofort nach Empfang vorsichtig den Karton auspacken und den Inhalt berpr fen Alle Teile m sse...

Page 8: ...ren oder weggleiten Achten sie darauf dass die Struktur die das Ger t tr gt mindestens 10 mal das Eigengewicht des Ger ts tragen kann Benutzen Sie zus tzlich ein Sicherheitskabel das 12 mal das Eigeng...

Page 9: ...A4 Mode Auto setting Cyclical changes Speed 1 9 S1 Mode Sound active setting Speed 1 9 S2 Mode Sound active setting Flash Speed 1 9 S3 Mode Sound active setting Not Flash Speed 1 9 C01 Mode Gobo 01 Sp...

Page 10: ...s partes inerentes ao produto Instru es de Seguran a Leia com aten o as instru es pois as mesmas cont m informa o importante acerca da instala o utiliza o e manuten o do produto Guarde este manual de...

Page 11: ...onais e deve ser fixado num local longe de pessoas e que n o tenha uma passagem por cima ou por baixo do mesmo Opera o A unidade pode ser operada atrav s de controlo DMX512 ou usada como uma unidade i...

Page 12: ...ve setting Flash Speed 1 9 S3 Mode Sound active setting Not Flash Speed 1 9 C01 Mode Gobo 01 Speed 2 9 C02 Mode Gobo 02 Speed 2 9 C03 Mode Gobo 03 Speed 2 9 C04 Mode Gobo 04 Speed 2 9 C05 Mode Gobo 05...

Page 13: ...atii importante privind instalarea utilizarea si intretinerea produsului Va rugam sa pastrati acest Ghid de Utilizare pentru referinte ulterioare Daca vinde i aparatul unui alt utilizator asigurati va...

Page 14: ...fie la indemana nimanui astfel incat nimeni sa nu poata trece pe langa sau pe sub el Functionare Unitatea poate fi actionata prin dispozitivul DMX512 de control sau poate fi utilizat ca o unitate ind...

Page 15: ...de Gobo 07 Speed 2 9 C08 Mode Gobo 08 Speed 2 9 C09 Mode Gobo 09 Speed 2 9 C10 Mode Gobo 10 Speed 2 9 C11 Mode Gobo 11 Speed 2 9 C12 Mode Gobo 12 Speed 2 9 d Mode DMX setting Curatarea dispozitivului...

Page 16: ...ja od tiste ki je navedeno na koncu navodil Ta izdelek je namenjen za zunanjo uporabo Da bi prepre ili nevarnost po ara ali elektri nega udara ne izpostavljajte izdelka de ju ali vlagi Prepri ajte se...

Page 17: ...i enoto Obstajajo trije na ini za delovanje enote A Master Slave delovanje B Zvo na aktivacija in samodejni na in C Univerzalni DMX kontroler A Master Slave delovanje V na inu master slave lahko pove...

Page 18: ...ed 2 9 C12 Mode Gobo 12 Speed 2 9 d Mode DMX setting i enje enota i enje notranjih in zunanjih opti nih le in ogledal se mora izvajati redno za optimalno oddajanje svetlobe Pogostost i enja je odvisna...

Page 19: ...mian bezpiecznika Bezpieczny monta urz dzenia przy u yciu linki bezpiecze stwa Nale y u ywa uchwyt w Maksymalna temperatura otoczenia to 40 C Nie u ywaj urz dzenia w temperaturach wy szych ni podana W...

Page 20: ...racy w AUTO lub kontroli d wi kiem Podrz dne jednostki adres startowy DMX musi by ustawiony na d001 WY WIETLACZ LED USTAWIENIA DMX D001 D512 K1 LED Dimmer 0 255 K2 B ysk 0 255 K3 Ruch Gobo 0 255 K4 Ru...

Page 21: ...wek i lub lustra musi by przeprowadzana okresowo w celu optymalizacji mocy strumienia wiat a Cz stotliwo czyszczenia zale y od rodowiska w kt rym sprz t jest u ywany wilgotnych lub szczeg lnie brudnyc...

Reviews: