©Copyright LOTRONIC 2017
HYPNO40-LED
Page 3
•
Operating modes: Auto, sound, DMX, Master-slave & remote controlled
•
Remote control
Power supply .................................................................................................. 110-240Vac 50/60Hz
Consumption ................................................................................................................... 50W max.
Fuse ............................................................................................................. F3AL 250V
Ø
5 x 20mm
DMX channels ................................................................................................................ 8 channels
Light source ................................................................................... 4 x 10W RGBW CREE LED 4-in-1
Beam angle ................................................................................................................................... 4°
Dimensions ....................................................................................................... 155 x 110 x 150mm
Weight ..................................................................................................................................... 1.5kg
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of
channels required by all fixtures on a serial data link determines the number of fixtures that the data link can
support.
Important
: Fixtures on a serial/data link must be daisy chained in one single line. Maximum recommended serial
data link distance: 100 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link: 32 fixtures
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to
connect a DMX signal terminator.
CAUTION
Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a
ground loop, and your fixture may perform erratically. Test cables with an ohm meter to check correct polarity and
to make sure the pins are not grounded or shorted to the shield or each other.
Setting up a DMX Serial Data Link
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the controller.
2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connector to the input
connector of the next fixture consisting of a (male) 3 pin connector.
3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
DMX address setting
Each fixture must have a specific starting address. When receiving signal transmission, every fixture will receive
channels control signals for its own starting address.
The user can set several fixtures to the same address or set up a separate address for every device.
If more than one fixture is set to the same address, all of them receive the same DMX channels signals. All connected
fixtures are jointly controlled; the controller can't control a device separately.
If every device is set to a different address, it will receive different DMX signals corresponding to its starting address.
This device has 8 channels, so the first device starting address is set 1, second is 9 (1+8), third is 17 (9+8) and so on.
INPUT
COMMON
DMX +
DMX-
Resistance 120 ohm
1/ 4w between pin 2
(DMX-) and pin 3
(DMX+) of the last
fixture.