It is good practice to change the water of the boiler at the end of each working day
as follows:
1) Switch off the machine by turning the three way power switch (18) to the off
position. (ONE GROUP MACHINE: This switch only has two positions [ON-OFF])
2) Open the steam controls (8) until no steam is coming out. (Use the steam jets (12)
with care, during normal working are extremely hot).
3) Close the steam control.
4) Open the drain-out tap (28) until completely empty.
5) Close the drain-out tap (28).
6) Restart the machine by turning the three-way switch (18) to the position 1 and wait
automatic fill up control will have finished filling up the boiler with fresh water.
1.10.- WATER SOFTENER
The water softener eliminates calcium from the water therefore preventing the build up
of inlays. The water softener degenerates through use and must be regenerated. Regeneration
is the procedure which returns them to the original state. The presence of inlays in the boiler,
through lack of regeneration, will nullify all guarantees in force. (Water softener is not
included).