5.2. USING ELECTRIC APPLIANCES:
WARNING:
Make sure that the appliance is switched OFF before connecting it to the generator.
Do not move the generator while it is running.
5.2.1. AC APPLICATION:
5.2.2. Check the volt meter for sufficient voltage.
5.2.3. This generator is properly tested and adjusted and
set at the factory.
5.2.4. If the generator does not produce the specified
voltage please contact your local dealer.
5.2.5. Turn off the switch(es) of the electrical appliance(s)
before connecting to the generator.
5.2.6. Insert the plug(s) of the electrical appliance(s) into
the receptacle/socket.
5.2.7. Check the amperage of the receptacles/sockets used
making reference to the TABLE and be careful not to take a
current exceeding the specified amperage.
5.2.8. Check that the total wattage of all appliances that is
being connected to the generator does not exceed the
rated output of the generator.
5.2.9. Turn on the appliance switch.
NOTE: If the circuit breaker "TRIPS" during operation the generator is overloaded or the
appliance is defective. Stop the generator immediately and check the appliance and /or
generator for overloading.
ON
OFF
5.3. CONNECTING TO DOMESTIC CIRCUITS (HOUSE WIRING):
WARNING:
If a generator is to be connected to residential or commercial power lines for stand-by
power during power outage - all connections must be made by a competent person or
licensed electrician. Connection failure, or improper connection, may result in death,
personal injury, damage to the generator, damage to the appliances, damage to the
building's wiring, or even result in a fire.
5.3.1. When connecting the generator to the house wiring the generator output power
must be taken from the 230V receptacle/socket.
5.3.2. A transfer switch must be installed to transfer the load from the commercial power
source to the generator. This switch is necessary to prevent accidents caused by the
recovery from power outages. Use a transfer switch of the correct capacity. Install the
transfer switch between the meter and the fuse or AC Breaker Box.
CAUTION:
If the neutral wire of the house wiring is earthed, be sure to earth the ground terminal of
the generator. An electric shock may result if this procedure is not followed.
UTILITY HIGH LINE
CONNECTING BOX
TRANSFER
SWITCH
MAIN POWER LINE