IWT 65 (135 °F)
Boiler
Output
(BTU/Hr)
Boiler Flow = 14 gpm / 160 °F
Boiler Flow - 14 gpm / 180°F
1st Hour Rating
(Gal/Hr)
Continuous rating
(Gal/Hr) 58°F entering
cold water
1st Hour Rating
(Gal/Hr)
Continuous rating
(Gal/Hr) 58°F entering
cold water
50,000
116
60
134
78
60,000
128
72
149
93
80,000
151
96
179
124
100,000
174
120
209
156
120,000
198
144
239
187
140,000
221
168
269
218
160,000
244
192
300
249
180,000
252
199
309
259
Table 5
Recovery rates - IWT 65
IWT 80 (135 °F)
Boiler
Output
(BTU/Hr)
Boiler Flow = 14 gpm / 160 °F
Boiler Flow - 14 gpm / 180°F
1st Hour Rating
(Gal/Hr)
Continuous rating
(Gal/Hr) 58°F entering
cold water
1st Hour Rating
(Gal/Hr)
Continuous rating
(Gal/Hr) 58°F entering
cold water
50,000
136
60
153
78
60,000
147
72
168
93
80,000
171
96
198
124
100,000
194
120
228
156
120,000
217
144
259
187
140,000
240
168
289
218
160,000
263
192
319
249
180,000
287
216
349
280
200,000
292
221
356
287
Table 6
Recovery rates - IWT 80