Safety information

Manual safety markings

Danger

Points out an immediate hazardous

situation that must be avoided to

prevent serious injury or death.

Warning

Points out a potential hazardous situation

that must be avoided to prevent serious

injury or death.

Caution

Points out a potential hazardous

situation that must be avoided to

prevent possible moderate injury

and/or property damage.

Note

Points out installation, maintenance and

operational notes to enhance efficiency,

longevity and proper operation of the

boiler.

Important safety instructions

Installation, start-up and servicing of IBC boilers must be performed by competent, qualified, licensed and

trained heating technicians.

Failure to read and comply with all instructions and applicable national and local codes may result in

hazardous conditions that could result in property damage and injury to occupants, and in extreme cases to

death. Keep instructions near the air handling unit for future reference.

Danger

Should overheating occur or the gas supply fails to shut off, do not turn off or disconnect the

electrical supply to the pump. Instead shut off the gas supply at a location external to the

appliance.

Warning

Keep boiler area free and clear of combustible materials, gasoline, and other flammable vapors

and liquids.

Warning

Combustion air must not be drawn from areas containing corrosive air from swimming pools or

spas, including air directly next to outdoor pools and spas.

Warning

The boiler must not be exposed to water leaks from piping or components located overhead. This

includes condensation dropping from un-insulated cold water lines overhead.

Summary of Contents for EX 850

Page 1: ...s and liquids or other combustible materials in the vicinity of this or any other appliance If you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone i...

Page 2: ...he amount of solids that may form on the heat exchanger will depend on the degree of hardness and the total water volume in the system A high water volume system with a low hardness count may cause as...

Page 3: ...3 Important safety instructions 3 Domestic hot water 6 Boiler operation 8 Lighting and shutting down the boiler 8 Service and maintenance 9 Maintenance checklists 9 Relief valve maintenance and testin...

Page 4: ...Intentionally left empty...

Page 5: ...with all instructions and applicable national and local codes may result in hazardous conditions that could result in property damage and injury to occupants and in extreme cases to death Keep instru...

Page 6: ...g installation start up operation or service Installation and service must be performed only by an experienced skilled installer or service agency Failure to follow all instructions in the proper orde...

Page 7: ...and use of respirators certified by NIOSH For the most current information NIOSH can be contacted at 1 800 356 4676 or on the web at www cdc gov niosh 2 Wear long sleeved loose fitting clothing glove...

Page 8: ...being scalded Never leave then unattended in or near the shower bathtub or sink Never allow small children to use a not water faucet or draw their own bath To avoid any potential scald hazard or if co...

Page 9: ...Warning Bacteria growth can develop in domestic hot water tanks and indirect water heaters if the minimum water temperature is not set high enough to prevent its growth 7 Domestic hot water...

Page 10: ...Boiler operation Lighting and shutting down the boiler 8 Section Contents...

Page 11: ...al contaminates Monthly Maintenance Check Check all the Daily Maintenance items Check the pressure relief valve and discharge piping for signs of leakage or moisture If water or moisture is found cont...

Page 12: ...heck the ignition electrode and remove oxidation from the electrode Replace if necessary Check the gas valve and ignition cable Check the controller settings Check the burners flame Should be a quick...

Page 13: ...that under normal operating conditions a try lever test must be performed every two months Under severe service conditions or if corrosion and or deposits are noticed within the valve body testing mu...

Page 14: ...Revision history R0 September 2019 Initial release...

Page 15: ...IBC Technologies Inc 8015 North Fraser Way Burnaby BC Canada V5J 5M8 Tel 604 877 0277 Fax 604 877 0295 Toll Free 1 844 432 8422 www ibcboiler com November 2019 IBC Technologies Inc 2019 120 329...