AST1029MP-960
Page 9
20/11/2006
•
To input
“HARDNESS”
Note: this program will only accept a figure rounded to the nearest “TEN”. Eg for a
hardness of say 183 the 190 will have to be programmed in the setting ie the next higher
“TEN” number will have to be selected.
Wait till the green light moves to the “TIME OF DAY” then using the
ò
button keep
pressing till the green light moves down to “HARDNESS” then press “SET” button.
The ten digit (second from the left) will blink, using the
ñò
buttons input the numeral
required eg. 190 hardness input
9
Using the
ï
button select the next blinking digit and using the
ñò
buttons input the
numeral required, eg. 190 hardness input
1
Using the
ï
button select the next blinking digit which normally should be zero ‘0’ for
most water harness if the display shows any other number other than zero then use
the
ò
button to bring it back to zero and then press “SET”.
The softener has now been programmed and can now go into service. However, it is
advisable to check the settings in the program, wait till the green light moves to “TIME OF
DAY”.
•
Check time of day is correct
•
Press
ò
button to “TIME OF REGENERATION” 2:00 should be displayed
•
Press
ò
button to “HARDNESS” the hardness figure that you put in should be displayed
•
Press
ò
button “SALT AMOUNT” take note of the figure displayed. Refer to table 2 in
the manual under “SUGGESTED SALT SETTING” the figure should correspond to the
bottom number in the right hand corner, under “KG OF SALT” heading.
•
Press the
ò
button to “CAPACITY” take note of the figure displayed again refer to table
2 and the displayed number should correspond to the number at the bottom number
under “KILGRAMS OF HARDNESS CAPACITY”.
Please note: When the display goes back to alternating the green light between “TIME OF
DAY” and “CAPACITY” that the capacity display NOW will be different to what has just been
checked, what is now displayed is the volume of water that the softener will pass in “CUBIC
METRES” before regenerating. However, when using the
ñò
buttons to check this setting
the microprocessor will display the “EXCHANGE HARNESS CAPACITY OF THE
SOFTENER” and this can be modified if required, see the manual for full details.