AS1029MP-CL
Page
9
The WS1-E1 has been factory programmed with the majority of the commands and parameters installed. It is
necessary on commissioning of the softener to program in the
M
3
throughput
” and if desired another
time of
day
when regeneration is to proceed or accept the
factory default of 2am
and to set up the clock to register
the current time of day. The transformer plugs into the socket mounted on the back face of the front panel of
the valve
The procedure is as follows :
Plug in the transformer into the mains and turn on – valve will sequence to the service position
.
CUSTOMER/ INSTALLER
PROGRAMING INSTRUCTIONS
Step 1I
– To enter installer display press the
NEXT
and
▲
buttons simultaneously for 5 seconds and
release. Display flashes.
Step 2I
– Using the
keys
input desired
volumetric
throughput
capacity (table 2 ) in cubic
meters ( Adjustable from 0.5 - 250.0). It is suggested
the value entered be equal to the actual volumetric
capacity minus a 1 day’s estimated water usage.
Press
NEXT
to go to Step 3I
Step 3I
– Use or buttons to Set to “OFF” .
Press
NEXT
to go to Step 4I.
Step 4I
– Use or buttons to set the time of regen
‘hour’
. Press
NEXT
to go to Step 5I. If the factory
default of 2am is to be changed.
Step 5I
– Use or buttons to set the time of regen
‘minutes’
. Press
NEXT
to
exit
installer display.
Setting Current Time of Day
Push
NEXT
button until
TIME
of day screen is
displayed ie bar appears under TIME function . Press
and hold the OR arrow until a arrow appears
against SET and
release
the button and the hour
display flashes and then set the correct hour. Then
press the
NEXT
button. The minutes will flash. Press
the
OR
arrow until the correct minutes is
displayed. Note only press
one
▲
OR
▼
button NOT
both together.
Press the NEXT button to return to the display screens.
If the NEXT button is not pressed hours or minutes will
flash for five minutes before returning to display
screen.
Then using the
NEXT
button select which screen you
wished displayed. Recommended to leave on
‘
remaining-M
3
’
.
Exit back to display screen which would normally show
‘remaining M
3
’. Note: When in the program mode. Step 1 to
5. If it is desired to go back one program step press ‘regen’
button to return back.
Summary of Contents for AS1029MP-CL
Page 3: ...AS1029MP CL Page 3...
Page 5: ...AS1029MP CL Page 5...
Page 11: ...AS1029MP CL Page 11 MODEL AS1029MP WATER SOFTENER WITH CONTROL VALVE SERIES MODEL WS1EI...
Page 19: ...AS1029MP CL Page 19...
Page 20: ...AS1029MP CL Page 20 WS1EI Screen Display Information And Programming Instructions...
Page 22: ...AS1029MP CL Page 22 General Regeneration Error Screens Status...
Page 29: ...AS1029MP CL Page 29 SPARE PARTS AND SERVICING INSTRUCTIONS...
Page 39: ...AS1029MP CL Page 39 flow diagram backwash Flow Diagram Downflow...
Page 40: ...AS1029MP CL Page 40 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Page 41: ...AS1029MP CL Page 41 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Page 49: ...AS1029MP CL Page 49 INJECTOR PERFORMANCE CURVES...
Page 50: ...AS1029MP CL Page 50...
Page 52: ...AS1029MP CL Page 52...