background image

ibaMS8xAI-110VAC 

Manual 

 

 

 

Issue 1.4.1 

21

 

 

 

Locked 

True:  the module can only be changed by an authorized user.  

False:   the module can be changed by any user. 

 

Enabled 

Data capturing for this module is enabled. 

 

Name 

You can enter a name for the module. 

 

Modul No. 

Consecutive module number assigned by ibaPDA for clearly referencing the sig-

nals, e.g. in expressions or ibaAnalyzer. The number can be changed by the user. 

 

Timebase 

Timebase, specified in the PADU-S module. 

 

Use name as prefix 

Prefix the signal names of this module with the module name. 

 

Configuration set by  

This item is only visible when ibaPADU-S-IT-2x16 is used as central unit. When an 

embedded application has been started on ibaPADU-S-IT-2x16 (e. g. ibaLogic), 

then ibaPDA cannot modify the configuration of the modules and signals. In this 

case the configuration is set by the embedded application. The following entries can 

be displayed: 

  ibaPDA 

 

When ibaPDA is displayed, an embedded application has not been started and 

the configuration can be set by ibaPDA. 

  Embedded application 

 

When embedded application is displayed, the configuration of the modules and 

signals is set by the embedded application on the device. In this case it is possi-

ble to import user-defined signal names, which are configured in the embedded 

application, provided that the embedded application supports this function (Import 

signal names: True). 

The modules and signals configured by the embedded application cannot be con-

figured in ibaPDA, they are displayed in gray in the respective fields. 

The configuration is read by ibaPDA and used for the acquisition. Modules and 

signals which are not displayed in gray can be used in ibaPDA. 

Advanced 

 

Digital filter mode  

When you select „Anti-aliasing“ then after the analog anti-aliasing filter an additional 

digital anti-aliasing filter is applied to the signals. This digital anti-aliasing filter can 

be enabled only once per module and is then applied to all signals, that have the 

filter property enabled on the “Analog” tab. This means, that the digital anti-aliasing 

filter can only be activated together with the analog filter by activating the filter op-

tion on the “Analog” tab. 

 

The digital anti-aliasing filter can only be enabled, when the sampling rate > 500 Hz 

(= timebase < 2 ms). 

When the digital filter is enabled, an additional field „Cutoff frequency“ appears. 

Summary of Contents for ibaMS8xAI-110VAC

Page 1: ...ibaMS8xAI 110VAC Input module for analog signals Manual Issue 1 4 1...

Page 2: ...red trademark of the Microsoft Corporation Other product and company names mentioned in this manual can be labels or registered trademarks of the corre sponding owners Certification The product is cer...

Page 3: ...2 Connecting 11 6 3 Dismounting 11 7 Device description 12 7 1 Views 12 7 2 Indicator elements 13 7 2 1 Operating status 13 7 2 2 Status of the analog inputs 13 7 3 Analog inputs 13 7 3 1 Filter 13 7...

Page 4: ...ab 22 9 1 3 Grid frequency 10Hz 80Hz tab 23 9 2 Configuration in ibaLogic V5 25 9 2 1 Configuring signals 25 9 2 2 Additional functions 27 10 Technical Data 30 10 1 Main data 30 10 2 Analog inputs 30...

Page 5: ...included in delivery The documentation of the iba modular system comprises the following manuals Central units The manuals of the ibaPADU S IT 2x16 central units and ibaPADU S CM contain the followin...

Page 6: ...possible consequences and risks on the basis of his her specialist training knowledge and experience and knowledge of the standard regulations 1 2 Notations In this manual the following notations are...

Page 7: ...ocess and the system or machine to be controlled there is a risk of death or severe injury The non observance of this safety information may result in a potential risk of death or severe injury The no...

Page 8: ...p to 40 kHz freely adjustable Real parallel data capturing with an A D converter per channel Analog and digital filter per channel Grid frequency measurement Rugged design easy mounting Certification...

Page 9: ...r use damaged measuring cables Measuring cables must NOT be attached or detached to from the device under voltage The device must not be connected to CAT III and CAT IV categories The device is approv...

Page 10: ...necting Dismounting Works on the device must NOT be done when it is under voltage Always disconnect the central unit from the power supply Note Mount one or more modules on the right next to the centr...

Page 11: ...les 2 If all required cables are connected connect the central unit to the power supply 3 Switch on the central unit 6 3 Dismounting 1 Disconnect the central unit from the power supply 2 Remove all ca...

Page 12: ...Device description 7 1 Views 1 2 3 4 Fixing screws Operating status indicators L1 to L4 Status LEDs L26 to L33 of the analog inputs 00 to 07 Connector X1 for analog inputs 00 to 07 Figure 1 Front vie...

Page 13: ...ates a failure please contact the iba Support 7 2 2 Status of the analog inputs LED per channel Status meaning Description approx values L26 L33 Off No signal signal too low 0 V 3 V Green Within measu...

Page 14: ...ency signals are available as virtual signals in the signal tree and can be displayed recorded and used for calculations like all other signals For configuration refer to chapter 9 1 3 Grid fre quency...

Page 15: ...e connection Figure 4 Connection diagram Pin assignment X1 Pin Connection LED 1 Analog input 00 L26 2 Analog input 00 3 Analog input 01 L27 4 Analog input 01 5 Analog input 02 L28 6 Analog input 02 7...

Page 16: ...ules developed up to the date of release of this firmware and the corresponding software versions If a module cannot be de tected yet i e it is more recent than the Firmware version of the CPU this mo...

Page 17: ...te Figure 5 Update via Web interface 8 3 2 Update via ibaPDA Open the ibaPDA I O Manager and choose your iba modular system in the tree structure On the Diagnostics tab click on the Write firmware but...

Page 18: ...b Open the ibaPDA I O Manager and choose your iba modular system in the tree structure see also the figure above 8 4 2 Web Interface On the module Website general information about the module is displ...

Page 19: ...anual Issue 1 4 1 19 8 4 2 2 notes tab On the notes tab you can enter notes e g for notes on wiring or on recording of changes By clicking on save notes the notes are permanently stored on the device...

Page 20: ...Automatic detection of the module Note The automatic detection requires a bidirectional FO connection from the ibaPDA com puter to the central unit Other documentation If you want to install the iba m...

Page 21: ...splayed the configuration of the modules and signals is set by the embedded application on the device In this case it is possi ble to import user defined signal names which are configured in the embed...

Page 22: ...pling rate The entry 0 Hz corresponds to the setting Auto Enable frequency measurement Select TRUE if you want to measure grid frequency of the connected signals The Grid frequency 10Hz 80Hz tab appea...

Page 23: ...can select the antialiasing filter Butterworth 4th order 20 kHz Active Enabling disabling the signal You can show or hide more columns via the context menu click with the right mouse button in the he...

Page 24: ...S8xAI 110VAC 24 Issue 1 4 1 1s or 10 s according to DIN EN 61000 4 30 Active Enabling disabling the signal You can show or hide more columns via the context menu click with the right mouse button in t...

Page 25: ...cription in the separate ibaPADU S IT 2x16 manual This manual describes only the signals belonging to this module 9 2 1 Configuring signals The signals can be configured in the I O Configurator of iba...

Page 26: ...u need to apply the Buffered Access by clicking on the Apply button Only then you will see additional signals in the signal tree that can be configured as output or input resources Signal Description...

Page 27: ...f Input buffer of analog input signals AI_Frequency_Ch 00 07 _buf Input buffer of calculated grid frequencies BufferFillCount Counter when buffer is filled BufferOverrun Counter for Buffer overrun Add...

Page 28: ...similar to the analog filter configuration as described above The meaning of the parameters in detail Digital anti aliasing filter DigitalFilterMode The digital anti aliasing filter can only be enable...

Page 29: ...aMS8xAI 110VAC Manual Issue 1 4 1 29 Setting of the interval for grid frequency measurement PwrFrwqMode 1 Measuring interval 1 s 2 Measuring interval 10 s according to DIN EN 61000 4 30 Data type USIN...

Page 30: ...tion Vertical plugged into backplane bus Installation height Up to 6562 ft 2000 m Humidity class acc to DIN 40040 F no condensation Protection class IP20 Certification Standards EMC IEC 61326 1 Safety...

Page 31: ...cy range 0 Hz to 20 kHz Accuracy 0 1 of total measuring range Electrical isolation Channel channel Channel housing power supply AC 1 5 kV AC 1 5 kV Measuring overvoltage 1500 V transient overvoltage C...

Page 32: ...Manual ibaMS8xAI 110VAC 32 Issue 1 4 1 10 4 Dimensions Figure 18 Module dimensions dimensions in mm...

Page 33: ...he product Contact Headquarters iba AG Koenigswarterstrasse 44 D 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E mail iba iba ag com Mailing address iba AG Postbox 1828 D 90708 Fuerth...

Reviews: