R/C low pass 40 kHz
Output signal range
-10 V to +10 V
-20 mA to +20 mA
Load
≥ 1 kΩ
≤ 500 Ohm Ω
Output frequency
Up to 40 kHz
2
, freely adjustable
Delay
8 µs + 12 µs (setting time until 90 % of the output
value is reached)
Accuracy
< 0.1 % of total measur-
ing range
< 0.5 % of total measur-
ing range
Electrical isolation
Root-root
Root-housing/power supply
AC 2.5 kV
AC 2.5 kV
Connector type
4 x 12-pin multi-pin connector, screw-type terminal
(0.14 mm
2
to 1.5 mm
2)
, included in delivery
Protective functions
Safe state
Channel root switched off
Current limitation
Short circuit protection
Hardware error (e. g. over temperature) The root switches to
„safe state“, when connection is
incorrect (resettable via software)
2