background image

 

ibaMS16xAO-10V/-20mA 

Output module for output signals 

 

Manual 

Issue 1.4 

Summary of Contents for ibaMS16xAO-10V/-20mA

Page 1: ...ibaMS16xAO 10V 20mA Output module for output signals Manual Issue 1 4 ...

Page 2: ...istered trademark of the Microsoft Corporation Other prod uct and company names mentioned in this manual can be labels or registered trade marks of the corresponding owners Certification The product is certified according to the European standards and directives This prod uct meets the general safety and health requirements Further international customary standards and directives have been observe...

Page 3: ...1 Views 12 7 2 Indicator elements 13 7 2 1 Operating status L1 L4 13 7 2 2 Status of analog outputs L26 L41 13 7 3 Analog outputs 13 7 3 1 Filter 13 7 3 2 Overload protection 14 7 3 3 Connection diagram pin assignment 14 8 Start up Update 16 8 1 Auto Update 16 8 2 Overall Release Version 16 8 3 Update 17 8 3 1 Update via Web interface 17 8 3 2 Update via ibaPDA 18 8 4 Module Information Diagnostic...

Page 4: ...Manual ibaMS16xAO 10V 20mA 4 Issue 1 4 10 Technical Data 27 10 1 Main data 27 10 2 Analog outputs 27 10 3 Dimensions 29 11 Support and contact 30 ...

Page 5: ... DVD that is included in delivery The documentation of the iba modular system comprises the following manuals Central units The manuals of the ibaPADU S IT 2x16 central units and ibaPADU S CM contain the following information Scope of delivery System requirements Description of the device Mounting Demounting Start up Configuration Technical data Accessories Modules The manuals for the single modul...

Page 6: ... possible consequences and risks on the basis of his her specialist training knowledge and experience and knowledge of the standard regulations 1 2 Notations In this manual the following notations are used Action Notations Menu command Menu Logic diagram Call of menu command Step 1 Step 2 Step 3 Step x Example Select menu Logic diagram Add New logic diagram Keys Key name Example Alt F1 Press keys ...

Page 7: ...process and the system or machine to be controlled there is a risk of death or severe injury The non observance of this safety information may result in a potential risk of death or severe injury The non observance of this safety information may result in a potential risk of injury or material damage Note A note specifies special requirements or actions to be observed Important note Note if some s...

Page 8: ...ts In brief I O modules for the iba modular system 4 galvanically isolated roots with 4 signals each Output level 10 V or 20 mA 16 bit resolution Output frequency up to 40 kHz freely adjustable Analog smoothing filter 40 kHz Rugged design easy mounting Certification according to CE The device driver and the firmware are saved on the module When switching on and booting the central unit the module ...

Page 9: ...ns Automation of industrial plants Applications with iba products The device is only to be used as shown in the Technical Data chapter 4 2 Special safety instructions Strictly observe the measuring range Never use damaged measuring cables Measuring cables must NOT be attached or detached to from the device under voltage Modules must NOT be attached or detached to from the rack under voltage Switch...

Page 10: ... the power supply Note Mount one or more modules on the right next to the central unit slot X2 to X5 can be freely selected 6 1 Mounting 1 Disconnect the central unit from the power supply 2 Remove the cover from the backplane bus to which the module should be attached 3 Attach the device to the backplane bus and press it firmly against the backplane 4 Secure the device with the fixing screws 5 Co...

Page 11: ...e central unit Note When switching on and off the power supply or the central unit it may be possible that intermediate values are wrong at the analog outputs for approx 5 seconds within the output signal range 6 3 Dismounting 1 Disconnect the central unit from the power supply 2 Remove all cables 3 Remove the both fixing screws on the upper and the lower side of the device 4 Pull the device strai...

Page 12: ... Operating status indicators L1 L4 Status LED L26 to L41 of the analog outputs 00 15 Connection X1 for analog outputs 00 03 Connection X2 for analog outputs 04 07 Connection X3 for analog outputs 08 11 Connection X4 for analog outputs 12 15 Figure 1 Front view 8 Grounding screw Figure 2 Bottom view ...

Page 13: ...Flashing Normal status no error Device error Important note When the LED L4 indicates a failure please contact the iba support 7 2 2 Status of analog outputs L26 L41 LED per channel Status Description ibaMS16xAO 10V Description ibaMS16xAO 20mA L26 L41 Off 0 V 0 mA Green 0 V 0 mA Red Channel error Channel error If an output is deactivated with ibaPDA the corresponding LED remains off 7 3 Analog out...

Page 14: ...g overtemperature all channels of a signal root are set to safe state 0 V or 0 mA The error must be reset by ResetError_Ch 00 15 in ibaLogic or Reset channel errors in ibaPDA see also chapter 9 1 2 7 3 3 Connection diagram pin assignment Here you can connect 16 output signals 0 15 each bipolar plus ground 4 separated galvanically isolated groups have 4 outputs each ibaMS16xAO 10V ibaMS16xAO 20mA F...

Page 15: ...11 L37 11 Analog output 03 11 Analog output 11 12 Analog output 03 12 Analog output 11 1 Analog output 04 L30 1 Analog output 12 2 Analog output 04 2 Analog output 12 L38 3 Analog output 04 3 Analog output 12 4 Analog output 05 4 Analog output 13 5 Analog output 05 L31 5 Analog output 13 L39 6 Analog output 05 6 Analog output 13 7 Analog output 06 7 Analog output 14 8 Analog output 06 L32 8 Analog...

Page 16: ...release version of the central unit the central unit does an automatic up or downgrade of the module Thereafter the module is ready to be used Important note The overall release version contains all modules developed up to the date of release of this firmware and the corresponding firmware versions If a module cannot be de tected yet i e it is more recent than the Firmware version of the CPU this ...

Page 17: ...ally 8 3 1 Update via Web interface Important note The Web interface is available only with the central unit ibaPADU S IT 2x16 Start the Website of the iba modular system in your browser and select the central unit On the update tab click on the Browse button and choose the padusit2x16_ v xx yy zzz iba update file By clicking on Start Update you start the update Figure 4 Update via Web interface I...

Page 18: ... via ibaPDA 8 4 Module Information Diagnostics 8 4 1 Diagnostics Important information about the iba modular system like hardware version firmware ver sion FPGA version and serial number is displayed in the Diagnostics tab Open the ibaPDA I O Manager and choose your iba modular system in the tree structure See also figure above 8 4 2 Webinterface On the module Website general information about the...

Page 19: ...eneral information and technical specifications of the I O module Figure 6 info tab 8 4 2 2 notes tab On the notes tab you can enter notes e g for notes on wiring or on recording of changes By clicking on save notes the notes are permanently stored on the device Figure 7 notes tab ...

Page 20: ...ure 8 Automatic detection of the module Note The automatic detection requires a bidirectional FO connection from the ibaPDA com puter to the central unit Other documentation If you want to install the iba modular system at first refer to the manual of the central unit chapter Configuration with ibaPDA 9 1 1 General settings If the module is detected click on the module in the signal tree and the G...

Page 21: ...se the configuration is set by the embedded application The following entries can be displayed ibaPDA When ibaPDA is displayed an embedded application has not been started and the configuration can be set by ibaPDA Embedded application When embedded application is displayed the configuration of the modules and signals is set by the embedded application on the device In this case it is possi ble to...

Page 22: ... that indicates whether the output is active Channel error state Status signal indicates whether the outputs of a root are in error state 9 1 2 Output Configuration Select the Output menu in order to configure the settings for the output signals The following settings apply to the Analog tab Figure 11 ibaMS16xAO 10V Outputs Analog tab ...

Page 23: ...l errors In the Outputs menu in the Reset channel errors tab the hardware errors of the quad roots of the outputs can be reset in two ways Manually using the Reset button Automatically by an output signal The following settings apply to the Reset channel errors tab Figure 12 ibaMS16xAO 10V Outputs Reset channel errors tab Name The quad roots have default names you can enter two additional comments...

Page 24: ... way of pro ceeding description in the separate ibaPADU S IT 2x16 manual This manual describes only the signals belonging to this module The signals can be configured in the I O Configurator of ibaLogic V5 Open the I O Con figurator in the Configuraton I O Configurator menu When you click on the Update Hardware button then ibaLogic detects the module ibaMS16xAO 10V has the following signal groups ...

Page 25: ...ibaMS16xAO 10V 20mA Manual Issue 1 4 25 All available status or failure information is listed under Inputs Figure 14 ibaMS16xAO 10V inputs ...

Page 26: ...ed 1 module is running 1 mistake e g module cannot be initialized StatusOut Status information about the plugged output module for input module without function 0 module not initialized 1 module is running 1 error e g module cannot be initialized Outputs AO_10V_Ch 00 15 or AO_20mA_Ch 00 15 Analog output channels INT 32768 32767 10 V 10 V or 20 mA 20 mA AO_ResetError_Ch 00_03 12_15 Resets the error...

Page 27: ...ransport temperature 13 F 158 F 25 C 70 C Installation position Vertical plugged into backplane bus Humidity class acc to DIN 40040 F no condensation Protection class IP20 Certification Standards EMC IEC 61326 1 FCC part 15 class A MTBF1 218 234 hours 24 years Dimensions and weight Dimensions width x height x depth 1 69 in x 8 43 in x 5 83 in 43 mm x 214 mm x 148 mm Weight incl packaging and docum...

Page 28: ...al measur ing range Electrical isolation Root root Root housing power supply AC 2 5 kV AC 2 5 kV Connector type 4 x 12 pin multi pin connector screw type terminal 0 14 mm2 to 1 5 mm2 included in delivery Protective functions Safe state Channel root switched off Current limitation Short circuit protection Hardware error e g over temperature The root switches to safe state when connection is incorre...

Page 29: ...ibaMS16xAO 10V 20mA Manual Issue 1 4 29 10 3 Dimensions Figure 15 Module dimensions dimensions in mm ...

Page 30: ...he serial number iba S N of the product Contact Headquarters iba AG Postbox 1828 DE 90708 Fürth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E mail iba iba ag com Contact Harald Opel Shipping address iba AG Gebhardtstr 10 DE 90762 Fürth Germany Regional and Worldwide For contact data of your regional iba office or representative please refer to our Website www iba ag com ...