11.2 Interfaces
ibaNet
ibaNet protocols
ibaNet 32Mbit Flex (bidirectional)
ibaNet 32Mbit 50µs / 100µs / 800µs
ibaNet 5Mbit
ibaNet 3Mbit
ibaNet 2Mbit
FO cable
2 ST plug connectors (62.5/125 µm) for RX and TX;
max. 2000 m cable length without repeater
Additional interfaces
Ethernet
2x RJ45, 1 Gbit/s
USB
1x USB 3.0, 1x USB 2.0
DisplayPort
Port for monitor
11.3 Digital inputs/outputs
Digital inputs
Number
2
Version
Electrically isolated, protected against polarity reversal, single
ended
Input signal
24 V DC
Max. input voltage
±60 V permanent
Signal level log. 0
Signal level log. 1
> -6 V; < +6 V
< -10 V; > +10 V
Input current
1 mA, constant
Debounce filter
Optionally with 4 different operating modes,
configurable in ibaPDA
Sampling rate
Max. 40 kHz, freely adjustable
Delay
typ. 10 µs
Electrical isolation
Channel-channel
Channel-housing
2.5 kV AC
2.5 kV AC
Connection technology
Screw-type terminal (0.14 mm
2
to 1.5 mm
2
), screw connection,
included in delivery
Digital outputs
Number
2
Version
Electrically isolated, solid-state DC switch
Switching voltage
max. 200 V DC, protection against surge voltages
Switching current
max. 350 mA (permanent), overcurrent protection
Switch delay
< 2 ms (at 100 mA)
ON resistance (log. 1)