Table of Contents 

Section 1 Connect to SapIP-LTE through TeraTerm……………….……………...……………………………..….…….....2 

 

 

 

Section 2 Verify SapIP Status……….………………………………………………………...……………………………..….…….....3 

 
 

Section 3 Verify LTE Status..………………………………………………………………...……………………………..….…….....4

 

 

 

Section 4 Verify Log & LTE communication…………………………..……………...……………………………..….…….....5 

 

Appendix: SAPIP-Cell-LTE Message Explanations………………………………...……………………………..…......6-10 

 

 

SAPIP-LTE Quick Start Guide 

Summary of Contents for SAPIP-LTE

Page 1: ...on 1 Connect to SapIP LTE through TeraTerm 2 Section 2 Verify SapIP Status 3 Section 3 Verify LTE Status 4 Section 4 Verify Log LTE communication 5 Appendix SAPIP Cell LTE Message Explanations 6 10 SAPIP LTE Quick Start Guide ...

Page 2: ...rt long long short short then repeat one more time The blinking sequence happens every 30 sec onds under normal operation Right window will show a red LED blinking This is Digi LTE module LED which blinks four times a second Run TeraTerm program from PC then select associated COM port click OK Go to Setup Restore Setup and navigate to C Program Files x86 teraterm folder and select SapIP TeraTerm i...

Page 3: ...35 Type SERNO to verify LTE address this is a 8 digit number that has to match with SapIP address on agrisensors net Type AVRS to verify heater voltage Refer to downloaded document to change heater setting Type INTER to verify logging interval Default interval is 15 15 minutes Refer to downloaded docu ment to change logging interval Type ADC to verify channel setting and labels Refer to downloaded...

Page 4: ...mands available and can be downloaded from here To verify signal strength without rebooting SapIP do the following Type to enter USB mode Type and hit ENTER to access LTE mode disappears and followed with a OK Type capital S then monitor the re sponse S character will be immedi ately followed by When done wait for LTE mode to time out and sign re appears Type EXIT to disconnect from SapIP ...

Page 5: ...econds it takes about 15 minutes for new data to be uploaded to agris ensors net website While waiting for the new data verify remote commands on agrisensors net SapIP control panel page Monitor SapIP response through TeraTerm Status Repeat Last Reading Show Device Config Update Date Time Send SMS to Device or send a single letter from cellphone to the listed SapIP number SapIP LTE doesn t wake up...

Page 6: ...fter the maximum wait time which may vary CTS HI OR OPEN The Clear To Send line is high not asserted and so the LTE module is present and working or the mod ule is removed from the board Wake up The CPU is waking up the LTE module SLEEP_RQ LO The CPU is commanding the LTE module to wake up CTS LO OK The Clear To Send line is asserted which means the module is present and working Wait 2 min for LTE...

Page 7: ...h memory setup ATDB The CPU requests a signal strength reading in dB Signal 93dBm A sample signal strength response Ready The CPU is finished setting up the LTE module ATAP4 The CPU is requesting mini Pascal mode for getting the date and time from the cellnetwork import utime as time time localtime Pascal command to get date and time 2019 4 15 15 24 0 0 105 Sample date time repsonse ATAP1 The CPU ...

Page 8: ...on java script command data string Got Commands Sample empty command string no commands in the buffer SENDING STATUS The CPU is sending a status message to the web server PUT service putRciResponse rci147782 XML HTTP 1 1 HTTP command to send data Content Type application xml Content Length 387 Content settings for type and length rci_reply version 1 1 do_command target async_sapip_rci get_records ...

Page 9: ...T service putData TEST sapDataGSM XML HTTP 1 1 HTTP PUT request for SAPIP data idigi_data sample name ZZ00890015 pComplete name value value sample idigi_data Sample data record encased within a Json string Got M status 15 the LTE network is disconnected Got M status 3 the cell tower is disconnected Buffer overrun the CPU was expcting a short message like SMS but got a long one like a delayeddata r...

Page 10: ...ter secs left gets to zero the module may go back to sleep SLEEP_RQ HI The CPU is putting the module to sleep LTEwakeup The CPU is going to wake up the LTE module GOT SMS The network sent an SMS wake up and the CPU will call CheckForCommands no modem The CPU thinks the modem chip was removed so it s going to skip any network operations ...