background image

 

Manual ibaCom-L2B-x-8

 

18 Issue 

3.2 

 

10 

Synchronizing Multiple iba PCI Devices 

Shut down the computer, remove the power connection and plug in the other iba PCI 
cards. 

Connect the synchronization cable between the devices. This is now necessary be-
cause the PCI bus does not support any synchronization signal on the bus which is 
available at all slot simultaneously. The sync cable (a 6-pole flat ribbon connector) en-
sures that all buffers (and data steams) of multiple fiber optic cards are exactly syn-
chronized. 

 

 

 

 

A bad or missing sync-connection may lead to inconsistent data blocks. This would af-
fect the data integrity and data correlation! 

 

 

Tip 

Every delivered card holds a spare jack plugged into the FPB PCI connector. Use this 
connector(s) and the flat ribbon cable to manufacture your own sync cable when 
needed. 

 

 

 

Installing additional components may alter your signal configuration (if a system up-
grade is made) and interrupt assignments. Save all settings before any changes are 
done. 

 

Start the PC again, boot windows and start PDA. 

 

Summary of Contents for Com-L2B-4-8

Page 1: ...PROFIBUS Interface PCI Board ibaCom L2B 4 8 and ibaCom L2B 8 8 ibaCom L2B x 8 Manual Issue 3 2 ...

Page 2: ... compliance is not guaranteed However the information in this publication is updated regularly Required corrections are contained in the following regulations or can be downloaded on the Internet The current version is available for download on our web site http www iba ag com Protection note Windows is a label and registered trademark of the Microsoft Corporation Other product and company names m...

Page 3: ... Activate Deactivate PROFIBUS Bus Terminal Resistors 10 6 Installation of the Board 11 6 1 Safety Instructions 11 6 2 Installing the Card 11 6 3 Removing the Card 12 7 Windows XP Driver installation 13 8 Software Configuration ibaPDA V6 15 9 Diagnosis in ibaPDA V6 16 9 1 General card diagnosis 16 9 2 Slave diagnosis 16 9 3 Processor information 17 9 4 Memory view 17 10 Synchronizing Multiple iba P...

Page 4: ...Manual ibaCom L2B x 8 4 Issue 3 2 11 1 6 ibaF0b_4 gsd 28 Real In Outputs 26 12 Technische Daten 28 13 Accessories 28 14 Support and contact 29 ...

Page 5: ...e she is capable of assessing safety and recognizing possible consequences and risks on the basis of his her spe cialist training knowledge and experience and knowledge of the standard regulations 1 2 Notations The following designations are used in this manual Action Notations Menu command Menu Logic diagram Call of menu command Step 1 Step 2 Step 3 Step x Example Select menu Logic diagram Add Ne...

Page 6: ...trol function The non observance of this safety information may result in a potential risk of death or severe injury The non observance of this safety information may result in a potential risk of injury or material damage Note A note specifies special requirements or actions to be observed Important note Note if some special features must be observed for example exceptions from the rule Tip Tip o...

Page 7: ...s or switches fully software controlled Firmware control in the PC without uninstalling the card Dynamic reassigning of interrupt sources and interrupt generation board and driver synchronization Up to 4 ibaL2B boards can run in the same PC at the same time board ids 0 3 4 DP slaves on one PROFIBUS line ibaL2B 4 8 or 2x4 DP slaves on 2 PROFI BUS DP lines ibaL2B 8 8 PCI Each PROFIBUS link has its o...

Page 8: ...PROFIBUS side GSD data 3 Scope of delivery After unpacking check the completeness and intactness of the delivery The scope of delivery includes Device ibaCom L2B x 8 Manual Synchronization cable preassembled GSD files 4 System requirements 4 1 Hardware IBM compatible PC with the following minimum configuration 400 MHz Pentium II or better 128 MB RAM or better At least one free PCI slot with 5V cab...

Page 9: ...ls The fol lowing table describes the states in which you may find the LEDs and their respective meanings On power on all LEDs are on for a few seconds to prove their proper func tion LED Status Indication Run green blinking off power is on and the channel is functioning properly controller stopped Link orange on off telegrams received sent on this channel no telegrams transmitted Err red on off i...

Page 10: ...PROFIBUS connector Channel B 5 1 5 PROFIBUS Multimaster Mode Each slave on the ibaL2B board can be assigned to be controlled by its individual mas ter This means that on one DP bus several masters may be active each controlling his slave s Note It is not allowed to assign more that one master to a slave 5 1 6 Activate Deactivate PROFIBUS Bus Terminal Resistors For each PROFIBUS line the line termi...

Page 11: ...lder chips or other parts of the device because this may damage the device and void your warranty 6 2 Installing the Card 1 Switch off the PC disconnect it from power supply and open it so that you can see the PCI slots 2 Unpack the card carefully Use a ground line or discharge any electrostatic charge from yourself before touching the card 3 No settings of jumpers or switches are required 4 Take ...

Page 12: ...emove the card from the PC please follow these steps 1 Stop and switch off the computer disconnect it from the power supply and open it 2 Release the screw in the front panel 3 Pull out the card off the PCI slot carefully and put in a safe place or conductive plas tic bag ...

Page 13: ...ws has finished its startup after booting the Found New Hardware Wizard pops up for introduction to the installation of the drivers In case the dialog should not open use the Windows Add Hardware Wizard in the control panel in order to look for new hardware If the dialog appears select No not this time Continue with Next In the next step select the option Install the software automatically and cli...

Page 14: ...2 The system is looking for driver software and installs it automatically Finally click on Finish If you like to check if the card was properly installed open the Windows Device Man ager and look for the card under the iba devices node ...

Page 15: ...interface icon in the tree you will get a simplified image of the card and essential information in the right part of the dialog Here you should set the required interrupt mode of the card and check the option In use in order to reserve the card for use by ibaPDA V6 only and not by other applications such as ibaLogic Example ibaCom L2B 4 8 in I O manager of ibaPDA V6 Each link of the card has assi...

Page 16: ...rs 5 1 1 and 5 1 2 Depending on the card type 4 ibaCom L2B 4 8 or 8 ibaCom L2B 8 8 processors can be found on the card s image A red cross on a processor indicates that the respective processor has no connection to the Profibus master A green hook indicates that the connection is established and stable Moreover the relation between bus connector and processor group including the de fault slave num...

Page 17: ... is for support service and error diagnosis only Processor information 9 4 Memory view This view provides very detailed information about memory use for service purposes It shows communication data and telegram contents The flashing green light indicates a running system Memory view ...

Page 18: ...sures that all buffers and data steams of multiple fiber optic cards are exactly syn chronized A bad or missing sync connection may lead to inconsistent data blocks This would af fect the data integrity and data correlation Tip Every delivered card holds a spare jack plugged into the FPB PCI connector Use this connector s and the flat ribbon cable to manufacture your own sync cable when needed Ins...

Page 19: ...n order to reduce bus traffic it is recommended to install GSD files for receiving only if sending is not needed The DP masters programming software e g S7 configurator defines the PROFIBUS Slaves for the DP masters But first the enclosed GSD data file must be loaded with your S7 configuration software Once the PROFIBUS is configured one or several L2B slaves can be activated S7 addresses are assi...

Page 20: ... Outputs Integer ibaLogic iba_0F09 gsd L2B32ROI GSD 32 Inputs Outputs Real ibaLogic 1 ibaF0b_4 gsd L2B28ROI GSD 28 Inputs Outputs Real for S7 400 ibaLogic ibaF0b_3 gsd L2B28SOI GSD 28 Inputs Outputs Real for S7 300 ibaLogic iba_0F05 gsd L2B_S7FP GSD S7 Request free variable access ibaPDA iba_0F0C gsd L2B_PLAN GSD QDA special function Sorcus Master ibaPDA ibaLogic 1 S7 400 Firmware V3 0 or higher S...

Page 21: ...hannel 8 15 7 6 23 22 21 20 19 18 17 16 Dig outputs channel 16 23 8 7 31 30 29 28 27 26 25 24 Dig outputs channel 24 31 9 8 MSB 10 LSB Analog output channel 0 Integer 2 byte Big Endian Motorola 11 10 MSB 12 LSB Analog output channel 1 Integer 2 byte Big Endian Motorola 12 Analog outputs in total 32 Words 16 bit integer Big Endian Motorola 71 70 MSB 72 LSB Analog output channel 31 Integer 2 byte Bi...

Page 22: ... 8 Dig outputs channel 8 15 7 6 23 22 21 20 19 18 17 16 Dig outputs channel 16 23 8 7 31 30 29 28 27 26 25 24 Dig outputs channel 24 31 9 8 MSB 10 11 12 LSB Analog output channel 0 Real 4 byte Big Endian Motorola 13 12 MSB 14 15 16 LSB Analog output channel 1 Real 4 byte Big Endian Motorola 16 Analog outputs in total 32 Longs Real Big Endian Motorola 133 132 MSB 134 135 136 LSB Analog output chann...

Page 23: ...nel 0 7 6 5 15 14 13 12 11 10 9 8 Dig outputs channel 8 15 7 6 23 22 21 20 19 18 17 16 Dig outputs channel 16 23 8 7 31 30 29 28 27 26 25 24 Dig outputs channel 24 31 9 8 MSB 10 11 12 LSB Analog output channel 0 Real 4 byte Big Endian Motorola 13 12 MSB 14 15 16 LSB Analog output channel 1 Real 4 byte Big Endian Motorola 16 Analog outputs in total 28 Longs Real Big Endian Motorola 117 116 MSB 118 ...

Page 24: ...us 72 Status customized functions possible e g status watchdog etc 11 1 4 2 DP Master Input data INPUT DATA Byte no Offset Contents Remark 1 0 FO message counter A incremented by each new FO message Bit 7 always 1 2 1 FO reception status Bit 0 FO reception OK Bit 3 0 integer 1 real 3 2 7 6 5 4 3 2 1 0 Dig inputs channel 0 7 4 3 15 14 13 12 11 10 9 8 Dig inputs channel 8 15 5 4 23 22 21 20 19 18 17...

Page 25: ...torola 135 134 not used 136 135 not used customized functions possible e g status watchdog etc 11 1 5 2 DP Master Input data INPUT DATA Byte no Offset Contents Remark 1 0 FO message counter A incremented by each new FO message Bit 7 always 1 2 1 FO reception status Bit 0 FO reception OK Bit 3 0 integer 1 real 3 2 7 6 5 4 3 2 1 0 Dig inputs channel 0 7 4 3 15 14 13 12 11 10 9 8 Dig inputs channel 8...

Page 26: ...tal 28 Longs Real Big Endian Motorola 117 116 MSB 118 119 120 LSB Analog output channel 27 Real 4 byte Big Endian Motorola 121 120 not used 122 121 not used customized functions possible e g status watchdog etc 11 1 6 2 DP Master Input data INPUT DATA Byte no Offset Contents Remark 1 0 FO message counter A incremented by each new FO message Bit 7 always 1 2 1 FO reception status Bit 0 FO reception...

Page 27: ...2 27 11 1 6 3 GSD File GSD filename Remark ibaF0_b4 gsd Transfer in one block with SFC S7 400 other masters ibaF0_b3 gsd Transfer in four blocks with SFC S7 300 11 1 6 4 Applications ibaLogic system coupling Simatic S7 TDC Simadyn D ...

Page 28: ...cted modules Distance between devices PROFIBUS line See PROFIBUS definitions Weight incl packaging and documentation 200g Number of PROFIBUS lines ibaCom L2B 4 8 1 ibaCom L2B 8 8 2 Number of signals ibaCom L2B 4 8 128 A 128 D 4 32 ibaCom L2B 8 8 256 A 256 D 8 32 13 Accessories Product Order no Description ibaFOB 4i S 11 115200 Expand the system to measure analog and binary inputs e g over ibaPADU ...

Page 29: ...require support specify the serial number iba S N of the product Contact Headquarters iba AG Koenigswarterstr 44 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 Email iba iba ag com Contact Mr Harald Opel Regional and Worldwide For contact data of your regional iba office or representative please refer to our web site www iba ag com ...

Reviews: