TECHNICAL DATA

Minimum dynamic pressure:_________________________________________________________0.5 bar
Maximum operational pressure:________________________________________________________5 bar
Recommended operational pressure:_________________________________________________1-5 bar
 

It’s recommended to use a pressure reducer in case of

 

static pressure superior than 5 bar inside the waterpipe.

Maximum hot water temperature:_______________________________________________________80°C

INSTALLATION, MAINTENANCE AND PRELIMINARY CHECKING PROCEDURE

In 

order to get your device work correctly and fi ne in time, must ensure compliance with the 

mode of installation and maintenance described in this booklet. Relying on a qualifi ed plumber. 
Make sure that the system is free from all debris and impurities existing.

INSTALLATION

Fig. 1:

 Connect the hoses to the spout and screw the tie-rod for fi xing it until it is completely 

locked.

Fig. 2:

 Make a hole on the surface MIN Ø32 mm - 1.25 in, MAX Ø36 mm - 1.41 in. Insert the 

hoses in the hole, positioning the fl at gasket under the spout.

Fig. 3:

 From under the surface, fi x the spout with the fi xing kit.

Fig. 4:

 Make on the surface two holes for the handles MIN Ø28 mm - 1.1 in, MAX Ø35 mm - 1.37 

in. Fit the fi xing set on the base. From under the surface, insert the base into the hole. Screw 
the bell on the base, positioning the gasket. Engage the handle and adjust the correct height of 
the bell, unscrewing it or screwing it. Fasten the fi xing set. Fix the handle with the screw, and 
screw the cover plate.

Fig. 5:

 Connect the hoses to the bases.

After connecting the body to the system, turn on the stopcocks and check that the mixer tap 
unit operates correctly. Keep the tap pressurised for a few minutes checking eventual leaks.

CLEANING

In order to obtain a correct cleanliness, exclusively wash them with soap and water, rewash and 
dry them with a soft towel and deerskin. Avoid the usage of alcohol, solvents, solid or liquid 
detergents which contain corrosive or acidic substances, abrasive sponges, swab with metallic 
strings because they could irreversibly compromise the surfaces.

THE USAGE OF THIS KIND OF DETERGNETS DURING THE CLEANING OF THE MIXER EXCLUDE 
IB RUBINETTERIE FROM ANY WARRANTY OBLIGATION.