Modello - Modèle - Model
Modell - Modelo
VIC CREAMY
Fabbricante - Constructeur
Manufacturer - Hersteller
Fabricante
EPTA S.p.A. - Sede legale
Via Mecenate, 86 - 20138 Milano – Italy
Capitale € 68.515.000 - R.E.A./MI – 1730229
Registro delle Imprese e Cod.Fiscale n. 04160730968
Partita IVA 04160730968
PAGE
15/68
N° DOC
UM000551
ENGLISH
SAFETY ADVICE
TRANSLATION OF ORIGINAL INSTRUCTIONS
WARNING! Do not damage the refrigerant circuit.
WARNING! Do not damage the inner or outer walls of the
appliance: the refrigerant fluid circuit may be damaged.
In case of damage to the walls, do not start the appliance
and contact a qualified service technician.
WARNING! This appliance must only be installed by
suitably qualified personnel in order to reduce the risks
connected with flammability.
WARNING! Keep the ventilation openings in the appliance
casing or in the recessed structure clear of obstructions.
WARNING! Never use mechanical devices or any other
means to accelerate the defrosting process, other than
those recommended by the manufacturer.
WARNING! Do not use electrical appliances inside the
compartments of the appliance for storing frozen foods if
these are not those recommended by the manufacturer.
Propane is a natural gas that doesn’t affect the
environment but is inflammable. It is therefore
essential to ensure that all refrigerant pipes are
not damaged before connecting the appliance to
the mains supply. Every 8 gr. Of refrigerant, the installation
room must have a 1 m³ minimum volume. The amount of
refrigerant of the appliance is indicated on the rating plate
of the device. In the event of leakage of the refrigerant,
avoid using open flames or sources of ignition in the vicinity
of the area of the leak. Be careful not to not damage the
refrigerant circuit pipes during positioning, installation and
cleaning.