background image

Modello - Modèle - Model

Modell - Modelo

GELÉ

Fabbricante - Constructeur

Manufacturer - Hersteller

Fabricante

EPTA S.p.A. - Sede legale

Via Mecenate, 86 - 20138 Milano – Italy

Capitale € 68.515.000 - R.E.A./MI – 1730229

Registro delle Imprese e Cod.Fiscale n. 04160730968

Partita IVA 04160730968

PAGE

13/50

N° DOC

4.  ENVIRONMENTAL PROTECTION AND REQUIREMENTS FOR

 

WASTE DISPOSAL AND TREATMENT

IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH 

EC DIRECTIVE 2012/19/UE

For reasons connected with the safeguard of the environment, and in compliance with what Directive 2011/65/EC and the relevant local 

national laws that establish, the cabinets for refrigerated products and frozens must be disposed of and recycled at the end of their life 

cycle. Making sure that this is achieved, the user significantly helps prevent potential repercussions on the environment and on the public 

health. Cabinets including a refrigerating circuit and a power plug (therefore ready to be installed) are defined WEEE: “Waste Electrical and 

Electronic Equipment”. 

Certain requirements concerning their treatment at the end of their life cycle must therefore be complied with:

•  Deliver the cabinets to the appropriate centres specialising in WEEE recovery and recycling.

•  Alternatively, return the cabinets to the seller or to the manufacturer.

• 

At any rate, collection of WEEE to be processed must be made following criteria that guarantee the protection of the cast-off appliances 

during transportation and during their loading and unloading. Do not leave the appliances unattended, not even for a few days.

• 

Avoid damaging the refrigeration circuit, as this contains fluids that may potentialy be hazardous for the environment and are subject 

to special prescriptions.

•  Make sure that doors are closed and fasten mobile parts accordingly.

• 

Remove the power plug from the cast-off appliances and cut off their power cord in order for them to become unusable.

The cabinet contains oil, inflammable cooling gas, plastic and metallic components and glass.

WARNING!

 Polyurethane insulation uses CICLOPENTHANE as expander, that doesn’t affect the environment but 

is inflammable. To guarantee the same respect when it’s disposed of , never abandon the equipment outside. 

Don’t throw the packaging material from your equipment in the rubbish but sort the various materials: 

eg.polystyrene, cardboard, plastic bags. 

The demolition of the cabinet and the recovery of the component materials must be carried out according to the 

local regulations in force in this matter.

WARNING! 

For out of use equipment:

•  Disconnect the power supply plug.

•  Remove the power supply cable and eliminate it together with the plug.

• 

Do not remove the drawers and various components inside the tank, to make it more difficult for children 

to enter the refrigerated chamber of the equipment. 

• 

Children are forbidden from playing with the decommissioned equipment. Danger of suffocation!

The equipment contains flammable gas inside the refrigeration circuit which must be appropriately 

disposed.

You need to avoid damaging the refrigerating circuit when dismantling the equipment.

5.  GENERAL INFORMATION

Take out packaging and clean all the cabinet using warm water together with 5% of neutral soap then dry it with a soft cloth; for the 

glass parts only use specific products, avoiding the use of water which can leave on the glasses limestone residues. 

It is fundamental to comply with the distances indicated (cm) 

for correct installation of the equipment.

• 

It is necessary that the capacitor unit is in the free air exchange condition, therefore 

the ventilation zones must not be obstructed by boxes or otherwise.

• 

Install and position the unit in such a way so as to allow easy access to the power 

socket.

• 

Never place containers of liquid on or immediately above the ticket counter; should 

the content spill out, it would damage the counter.

• 

The measured sound pressure emanated A is below 70dB (A).

10 cm

10 cm

The symbol       appearing on the rating plate of the appliance and on the documents attached indicates that:

• 

the product was issued after August 13, 2005;

• 

the product is subject to “separate collection”, and must not be treated as household waste and cannot be delivered at a landfill.

For further details on treatment, recovery and recycling of this product, contact the relevant local office, the household waste collection 

service or the seller that has sold the product.

WE DECLARE THAT THE CABINET IS CONFORMING TO RoHS 2011/65/EC DIRECTIVE.

Summary of Contents for GELE

Page 1: ...TH THE CABINET LIRE AVEC ATTENTION CE MANUEL ET LE CONSERVERPR S DU MEUBLE AVEC SOIN USER INSTRUCTIONS INSTRUCTIONS POURL UTILISATEUR SORGF LTING LESEN UND MIT DEM M BEL AUFBEWAHREN BETRIEBSANLEITUNGF...

Page 2: ...CONGELATI SE QUESTI NON SONO DEL TIPO RACCOMANDATO DAL COSTRUTTORE ATTENZIONE NON USARE DISPOSITIVI MECCANICI O ALTRI MEZZI PER ACCELERARE IL PROCESSO DI SBRINAMENTO DIVERSI DA QUELLI RACCOMANDATI DAL...

Page 3: ...RELATIVE ALL USO SICURO DELL APPARECCHIO E ALLA COMPRENSIONE DEI PERICOLI AD ESSO INERENTI I BAMBINI NON DEVONO GIOCARE CON L APPARECCHIO LA PULIZIA E LA MANUTENZIONE DESTINATA AD ESSERE EFFETTUATA DA...

Page 4: ...rito in discarica Per ulteriori informazioni sul trattamento recupero e riciclaggio di questo prodotto contattare l idoneo ufficio locale il servizio di raccolta dei rifiuti domestici o il rivenditore...

Page 5: ...io ragionevole tra i cibi per un migliore congelamento 9 TRASPORTO DEL MOBILE Il mobile contenuto in uno specifico imballo provvisto di pedana per la movimentazione con carrelli a forca Qualora si deb...

Page 6: ...igorifero osservare assolutamente i seguenti punti Non posizionare il banco refrigerato in prossimit di sorgenti termiche ad es termosifoni Evitare irradiazione solari dirette ad es attraverso finestr...

Page 7: ...ausa di rischi di infortunio Qualsiasi intervento effettuato sull apparecchiatura richiede assolutamente il distacco della presa di corrente e comunque nessuna protezione griglie carter va rimossa da...

Page 8: ...derivanti dalla mancata osservazione di questa norma 20 MANUTENZIONE ATTENZIONE La manutenzione deve essere eseguita da personale tecnico addestrato ed abilitato per interventi su refrigeranti infiam...

Page 9: ...endere circa 30 minuti 3 Rimuovere i tappi di drenaggio interno ed esterno e posizionare vedi figura una vaschetta per la raccolta dell acqua 4 Procedere all operazione di lavaggio ed asciugatura dell...

Page 10: ...ore Controllare che sul retro dell apparecchio vi sia spazio sufficiente per il passaggio dell aria Posizionare correttamente l apparecchio Utilizzatore Controllare l impostazione della temperatura Im...

Page 11: ...USE ELECTRICAL APPLIANCES INSIDE THE COMPARTMENTS OF THE APPLIANCE FOR STORING FROZEN FOODS IF THESE ARE NOT THOSE RECOMMENDED BY THE MANUFACTURER Isobutane is a natural gas that doesn t affect the en...

Page 12: ...SARY KNOWLEDGE AS LONG AS THEY ARE UNDER SUPERVISION OR AFTER THEY HAVE RECEIVED INSTRUCTION ON THE SAFE USE OF THE APPLIANCE AND OF THE DANGERS ASSOCIATED WITH IT CHILDREN MUST NOT PLAY WITH THE APPL...

Page 13: ...lammable To guarantee the same respect when it s disposed of never abandon the equipment outside Don t throw the packaging material from your equipment in the rubbish but sort the various materials eg...

Page 14: ...rait y avoir un espace raisonnable entre les produits pour une meilleure cong lation 9 TRANSPORTATION The display cabinet is contained in a specially crated package that enables transportation by the...

Page 15: ...of installation ensure that the following instructions are observed this being vital for proper and troublefree working of the cabinet Do not install the cabinet in the vicinity of heating radiators...

Page 16: ...or more parts of the equipment use of accessories that change its use and use of spare parts differing from those recommended can cause risks of accidents Any intervention on the equipment strictly r...

Page 17: ...dedicated to expert personnel are available From the service network In some product categories in paper form delivered with the product The spare parts and the information to repair the unit are avai...

Page 18: ...the same temperature 2 Put a basin of warm but not boiling waterinto the tank and close the glass lids for about 30 minutes 3 Remove the internal draining plug and place under the body if it s possib...

Page 19: ...ck that behind the cabinet air can properly circulate Position the equipment correctly User Check the temperature setting Set the correct temperature Technical support Check that there is not too much...

Page 20: ...TRIQUES L INT RIEUR DES COMPARTIMENTS DE L APPAREIL POUR LA CONSERVATION DES ALIMENTS SI CEUX CI NE SONT PAS DU TYPE RECOMMAND PAR LE FABRICANT L isobutane est un gaz naturel sans effet sur l environn...

Page 21: ...LLANCE DES PERSONNES AUTORIS ES ET OU APR S AVOIR RE U LES INSTRUCTIONS RELATIVES UN EMPLOI EN TOUTE S CURIT ET COMPRIS LES DANGERS LI S CET APPAREIL LES ENFANTS NE SONT PAS AUTORIS S JOUER AVEC L APP...

Page 22: ...cas la r cup ration des WEEE soumettre des op rations de traitement doit tre effectu e en adoptant des crit res qui garantissent la protection des appareillages utilis s seulement durant le transport...

Page 23: ...its pour une meilleure cong lation 9 TRANSPORT DU MEUBLE Le meuble est emball et pourvu d un socle en bois qui en permet le d placement par chariots l vateurs Dans le cas o il faille transporter nouve...

Page 24: ...TALLATION Pour un fonctionnement sans d faut de le banc les points suivants doivent absolument tre observ s lors du choix du lieu d implantation Ne pas installer le banc proximit de sources de chaleur...

Page 25: ...personnel non adapt ou autoris Installation non correcte ou tension d alimentation non adapt e l appareil Installation non correcte et ou d fauts d alimentation Non observation de ce manuel Modificati...

Page 26: ...ns des rallonges des adaptateurs ou des prises multiples Le branchement doit se faire par cons quent de mani re DIRECTE au r seau d alimentation Le c ble doit tre bien tendu dans une position l abri d...

Page 27: ...t d eau chaude mais non buillante et refermes les cou vercles pendant 30 minutes 3 Enlever le bouchon de decharge dans la cuve prevoir au dessous du meuble un bac pour la r cup ration de l eau 4 Proc...

Page 28: ...Positionner correctement l appareil Utilisateur Contr lerquederri rel appareililya tdel espacesuffisantpourlepassagedel air Positionner correctement l appareil Utilisateur Contr ler la programmation d...

Page 29: ...INE ELEKTRISCHEN GER TE IM INNEREN DER ABTEILUNGEN DES GER TS F R DIE AUFBEWAHRUNG VON TIEFGEFRORENEN NAHRUNGSMITTELN WENN DIESE NICHT DEN VORGABEN DES HERSTELLERS ENTSPRECHEN Isobutan sind nat rliche...

Page 30: ...E ANWEISUNGEN BER DEN SICHEREN GEBRAUCH DES GER TES UND BER DAS VERST NDNIS DER DAZUGEH RIGEN GEFAHREN ERHALTEN HABEN KINDER D RFEN NICHT MIT DEM GER T SPIELEN DIE REINIGUNG UND WARTUNG DIE VON DEM BE...

Page 31: ...dessen beim H ndler oder beim Hersteller abzuliefern Auf alle F lle muss die Abfuhr der WEEE die zu entsorgen und wiederzuverwerten sind so vonstatten gehen dass die ausrangierten Ger te w hrend des T...

Page 32: ...ORT DES K HLM BELS Das K hlm bel wird in einer Verpackung mit Holzgestell angeliefert und kann mit einem Gabelstapler gehandhabt werden F r den Transport des K hlm bels ist das daf r vorgesehene Geste...

Page 33: ...r einen st rungsfreien Betrieb des K hlregals sind bei der Wahl des Aufstellungsortes unbedingt nachstehende Punkte zu beachten K hlregal nicht in der N he von W rmequellen wie z B Heizungen aufstelle...

Page 34: ...er tes oder im Falle der Bedienung durch nicht bef higtes oder nicht autorisiertes Personal Der Fehlerhaften Installation oder einer f r dieses Ger t ungeeigneten Versorgungsspannung Der Missachtung d...

Page 35: ...tromnetz erfolgen Das Kabel muss durchgestreckt sein es muss an einer Stelle liegen an der es vor m glichen St en gesch tzt ist es darf sich nicht in der N he von Wasser oder anderen Fl ssigkeiten bef...

Page 36: ...ur in dem vorgesehenen Beh lter aufzubewahren 2 Stellen Sie die Beh lter mit warmem aber nicht hei em Wasser im Fahrgastraum auf schlie en Sie die Deckel und warten Sie eine halbe Stunde 3 Am Wannenbo...

Page 37: ...h das Ger t nicht in der N he einer Das Ger t richtig aufstellen Benutzer Kontrollieren dass hinter dem Ger t gen gend Raum f r die Luftzirkulation besteht Das Ger t richtig aufstellen Benutzer Die Te...

Page 38: ...RATOS EL CTRICOS EN EL INTERIOR DE LOS COMPARTIMENTOS DEL APARATO PARA CONSERVAR COMIDA CONGELADA A MENOS QUE ESTOS SEAN DEL TIPO RECOMENDADO POR EL FABRICANTE El isobutano es un gas natural sin reper...

Page 39: ...N O BIEN DESPU S DE HABER RECIBIDO INSTRUCCIONES SOBRE EL USO SEGURO DEL APARATO Y PARA LA COMPRENSI N DE LOS PELIGROS RELACIONADOS CON EL MISMO LOS NI OS NO DEBEN JUGAR CON EL APARATO LA LIMPIEZA Y...

Page 40: ...los WEEE para someter a operaciones de tratamiento se debe realizar con criterios que garanticen la protecci n de los aparatos desechados durante el transporte y durante las operaciones de carga y des...

Page 41: ...roductos para obtener una mejor congelaci n 9 TRANSPORTE DEL MUEBLE El mueble viene en un espec fico embalaje con paleta para su desplazamiento con carros elevadores a horquilla Si se debe lo transpor...

Page 42: ...n rendimiento sin fallos del medio de fr o observar absolutamente los siguientes puntos No colocar el medio de fr o en la proximidad de fuentes termicas por ejemplo termosifones Evitar radiazione sola...

Page 43: ...sto diferentes de las recomendadas pueden causar riesgos de accidentes Cualquier intervenci n en el equipo requiere sin excepci n que se desconecte la toma de corriente y de todos modos ninguna protec...

Page 44: ...pues la conexi n debe efectuarse de forma DIRECTA a la red de alimentaci n El cable tiene que estar bien tensado en una posici n al reparo de posibles golpes no debe estar cerca de l quidos agua ni fu...

Page 45: ...s refrigerados a la misma temperatura y sacar los entrepa os 2 Een bak met warm maar niet kokend water in de kuip zetten en de deksels er weer op doen ongeveer 30 minuten wachten 3 Sacar el tapon de d...

Page 46: ...e el equipo Usuario Controlar que detr s el aparato haya suficiente espacio para el pasaje del aire Ubicar correctamente el equipo Usuario Controlar la configuraci n de la temperatura Configurar corre...

Page 47: ...s the temperature inside the appliance B SLIDING LID C THERMOMETER D DEFROST DISCHARGE HOLE E VENTILATING GRID F WHEELS G CLOSURE SYSTEM H ELECTRONIC THERMOSTAT A BOUTON D AJUSTEMENT DE LA TEMP RATURE...

Page 48: ...i Gross volume Liters Volume brut l Bruttovolumen l Volumen Bruto litros 222 304 387 470 Volume Netto litri Net volume Liters Volume net l Nettovolumen l Volumen neto litros 185 256 327 398 Refrigeraz...

Page 49: ...i Gross volume Liters Volume brut l Bruttovolumen l Volumen Bruto litros 222 304 387 470 Volume Netto litri Net volume Liters Volume net l Nettovolumen l Volumen neto litros 185 256 327 398 Refrigeraz...

Page 50: ...i Gross volume Liters Volume brut l Bruttovolumen l Volumen Bruto litros 170 310 394 477 Volume Netto litri Net volume Liters Volume net l Nettovolumen l Volumen neto litros 126 238 305 372 Refrigeraz...