![IAI ELECYLINDER EC-RTC9 Instruction Manual Download Page 141](http://html1.mh-extra.com/html/iai/elecylinder-ec-rtc9/elecylinder-ec-rtc9_instruction-manual_3184366141.webp)
6.4 Parameter function descriptions
6-7
6. Parameter
s
Parameter No. 2: Auto switch "LS" signal detection range adjustment
No. Category
Name
Symbol
Unit
Input range
Default setting
at shipping
2
A
Auto switch
"LS" signal
detection
INP
degree Actuator Depended
to 9999.99
0.10
● Sets the backward complete / forward complete ON trigger range relative to the backward
end / forward end.
● When the ELECYLINDER enters the detection range, the backward complete or forward
complete signal turns ON.
● The minimum setting unit is 0.01 degrees.
The LS signal detection range for
the conditions below is shown in
the figure.
Backward end : 0.00 degrees
Forward end
: 100.00 degrees
Parameter No. 2 : 0.10 degrees
Caution
A value smaller than the minimum resolution cannot be set.
Minimum resolution [deg./p] = (360 ÷ reduction ratio) [deg./r] ÷ 800 [p/r]
Configuration example
Forward end
100.00 degrees
Backward end
0.00 degrees
[LS1 detection range]
99.90 to 100.10 degrees
[LS0 detection range]
-0.10 to 0.10 degrees
Summary of Contents for ELECYLINDER EC-RTC9
Page 2: ......
Page 26: ...1 5 Accessories 1 35 Power I O cable 1 35 Power I O connector 1 36...
Page 64: ......
Page 78: ...2 14 2 Installation...
Page 80: ......
Page 100: ...3 20 3 Wiring...
Page 124: ...4 22 4 Operation...
Page 126: ......
Page 132: ...5 6 5 Preventive Predictive Maintenance...
Page 134: ......
Page 148: ...6 14 6 Parameters...
Page 150: ......
Page 168: ...7 18 7 Troubleshooting...
Page 170: ......
Page 208: ......
Page 212: ......
Page 214: ...10 2 10 Life...
Page 216: ......
Page 219: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12...
Page 220: ......
Page 225: ......