background image

 

 

Grounding Cautions  (Continued) …………..

 

 
5.)

 

DON’T use power tools

 to install the nuts for the grounding kit. HAND TIGHTEN ONLY. If you    

   attempt to 'spin' the ground bolt, the serrated teeth under the head of the bolt might strip the thin     
       conductive layer. 

 
NOTE: 

If benches are moved to another location, the ground  bolts in the worksurfaces should be 

re-tested.  Refer  to  EOS/ESD  document  S4.1-1990  Worksurfaces-Resistive  Characterization  for 
proper  testing  methods.  If  ground  has  been  disturbed  between  the  bolt  and  the  static  dissipative 
laminate, DO NOT OVER TIGHTEN ground bolts to achieve proper ground. If ground cannot be re-
established, loosen nuts underneath bolt and remove ground bolt from hole. It may be necessary to 
hold the threads of the bolt with a small screwdriver in order to stabilize it to remove the nuts.  
 
Paint  a  thin  layer  of  CONDUCTIVE  ADHESIVE  or  CONDUCTIVE  PAINT  on  the  small  "ledge"  of 
conductive  laminate  where  the  bolt head rests and underneath THE HEAD of  the ground  bolt. Set 
bolt  back  into  the  hole  while  liquid  is  still  wet  and  test  ground  immediately.  At  the  point  ground  is 
reestablished, let the liquid dry before reattaching the ground wire.   
 

CLEANING:

  

Hard surface laminate is designed to resist abrasion, scuffing, scorching, hot solder, flux and most 
solvents.  Intense  exposure,  such  as  from  a  hot  soldering  iron  is  not  recommended.  The  surface 
cleans easily with a damp cloth and soapy water. A mild chemical cleaner with no abrasive can be 
used for stubborn spots. Remove glue and grease with a non flammable adhesive solvent such as 
3M Scotch-Grip Solvent No. 4-F. Stains can be removed with a two minute exposure to a 5% hypo 
chloride bleach solution, followed by a clean water rinse. Never wax surface, as waxes may insulate.

 

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 