5.6 Problem
Compressor is running too hot.
5.6.1 Possible Cause
Not enough air ventilation to Compressor
Remedy
: Make certain a sufficient amount of fresh air is supplied to the Compressor.
Dirty or Blocked Mesh
Remedy
: Check the flow of cooling air and clean the metal mesh of any debris blocking the air as
necessary.
5.6 Problem
Compressor will not operate (seized up).
5.7.1 Possible cause
Rotary Claws, Bearings or Gears stuck on..
Remedy
: Call service agent for service or exchange program
6.0 TECHNICAL DATA
Model
60Hz
50Hz
60Hz
0.8
1.4
1.8
2.2
~
1.2
2.2
0.6
1.2
1.6
2
0.8
-
1.6
2
50Hz
1
~
2
~
0.6
1.4
2.2
0.8
1.4
1.8
2
0.8
1.2
1.6
2
60Hz
9
11
13
15
~
13
18
13
18
22
26
18
-
26
36
50Hz
7.5
~
11
~
7.5
11
15
11
15
18.5
22
15
18.5
22
30
RPM - 60/50Hz
RPM
Voltage, Available
V
60Hz
50Hz
Oil Capa (Gear box)
Ltr
Inlet / Outlet Conn.
**BSP(G)
W x H (mm)
60Hz
1001
1171
1171
1171
~
1183
1183
1274
1274
1340
1395
1289
~
1410
1410
50Hz
961
~
1171
~
973
1183
1183
1274
1274
1274
1340
1289
1289
1355
1410
Amb. Operating Temp
(ºC)
Accessories
400
500
ICP
255
ICP
305
ICP
405
ICP
515
300
360
480
600
Press. Conti., Bar
Kw
M3/ Hour
208~230/460V, 220~240 / 380~420V, 400/690V
dB(A), Ave
82
82
83
83
79
80
81
82
3450 / 2850
250
300
L* (mm)
5ºC ~40ºC
Pressure Regulator, Safety Valve, Inlet Silencer, and Inlet Filter
Note: 1) * Length varies to motor mfg 2) **NPT threads available upon request
0.9
1.8
2"
3"
573 x 757
573 x 757
672 x 1003
672 x 1003
Note: Ultimate Continuous pressure operation will be possible within ambient operating
temperature between 5~40ºC.
Summary of Contents for ICP 255
Page 12: ...ASS y DRAWING ICP 255 305 IEC ...
Page 13: ...ASS y DRAWING ICP 255 305 NEMA ...
Page 17: ...ASS y DRAWING ICP 405 515 IEC ...