7. How to release female terminals
(
※
Female terminal releasing Jig dimentions see Fig39.)
①
Ensure that the secondary lock part and the retainer have been removed.
②
Hold the wire and push in the female terminal lightly. Place the female terminal releasing jig into the releasing apertures of the female housing
(see Figs. 38).
③
Push the releasing jig fully into the lance, then lever up the lance as shown in Fig.42
Keep the jig in the place and pull the female terminal out by holding the wire.
④
If there is any difficulty in pulling out the female terminal, do not pull it forcefully. Check that the jig is in the correct place, that it is pushed fully
in, etc. and repeat the procedures
①
to
③
.
Terminal releasing JIG: Part No. AP0004-01-005
Terminal releasing jig aperture
Terminal releasing jig
Fig39. Dimensions : Female Terminal releasing Jig
DETAIL A
DETAIL B
Fig38. Female housing and Direction of release
Place flat surface of the jig outside.