ISH & ISHV & ISHVS CONNECTOR Instruction Manual
Document No.
HDM-0002
12
/
29
Confidential C
※
Description of faults
:
Excessive conductors out & Incomplete conductors crimping
Please make sure there is no excessive conductors out and incomplete conductors crimping.
When retainer is inserted, excess conductors could push into adjacent terminals,
causing short circuit. (see Fig.21)
(
5
)
Incomplete insulation crimping
Strip length is too short and insulation is crimped inside the wire barrel (see Fig.22).
Strip length is too long and insulation does not fit completely inside the insulation barrel (see Fig.23).
(
6
)
Torn insulation
Insulation is torn by insulation barrel. (see Fig.24)
Fig 22.Strip too short
Fig 23.Strip too long
Fig 24. Torn insulation
Torn insulation caused
by insulation crimping.
Excessive conductors out
Short circuit caused by excess conductors
Fig 21. Short circuit caused by excess conductors
Incomplete conductors crimping