Step 2

Lubricate tailpiece O-ring with water. Insert flush valve tailpiece 

into control stop.

Step 3

Assemble vacuum breaker tube and spud escutcheon assemblies 

as shown. 

NOTE

: The vacuum breaker tube may need to be cut 

to fit properly. If using scored vacuum breaker, always cut from 

scored end and leave at least 1-1/4” (32mm) of scoring.

Step 4

Ensure flush valve is properly aligned with fixture and vacuum 

breaker tube. Tighten connections by hand.

Step 5

Once properly aligned, tighten connections with a smooth jaw 

wrench.

ProLAST

®

 T-SEAL & FLUSH VALVE CAP 

ASSEMBLY INSTALLATION

Step 1

Insert ProLAST® T-Seal into flush valve body.

Rev 080323

Summary of Contents for COBALT Pro 3200 Series

Page 1: ...materials are free from defects and are made to withstand normal use when installed properly Products have the following warranty periods 3 years for COBALT COBALT Pro and COBALT Connect faucets and f...

Page 2: ...KETC SET P SET P 21 533 L DIM 2 3 4 70 WALL THICKNESS 24 610 4 102 2 1 2 64 WALL OPENING 4 3 4 1 2 121 13 1 25 IPS SUPPLY CENTERLINE OF FIXTURE AND WALL SENSOR CENTERLINE OF SUPPLY TOP OF FIXTURE INST...

Page 3: ...ENGTH TO 0 1 IN ANNOTATION AND DIMENSIONING TEXT SHOULD BE ALL CAPS DUAL DIMENSION MEASUREMENT MILLIMETER SHOULD MATCH THE FRACTIONAL DISPLAY INCHES TEMPLATE INFORMATION PAGE SIZE 2 5 x1 5 CENTURY GOT...

Page 4: ...ded adapter to water supply pipe Step 3 Apply sealing compound to threaded adapter Tighten control stop onto threaded adapter using a smooth jaw wrench Step 4 Turn adjustment wheel on control stop CLO...

Page 5: ...ert flush valve tailpiece into control stop Step 3 Assemble vacuum breaker tube and spud escutcheon assemblies as shown NOTE The vacuum breaker tube may need to be cut to fit properly If using scored...

Page 6: ...ottom of flush valve cap assembly Place flush valve cap assembly onto flush valve body Step 3 Tighten locking ring by hand to flush valve body SENSOR PLATE INSTALLATION Step 1 Loosen set screw on plat...

Page 7: ...AY TO VERTICAL SET BENT LEADER LENGTH TO 0 1 IN ANNOTATION AND DIMENSIONING TEXT SHOULD BE ALL CAPS DUAL DIMENSION MEASUREMENT MILLIMETER SHOULD MATCH THE FRAC TEMPLATE INFORMATION PAGE SIZE 3 x3 CENT...

Page 8: ...e interface box Step 2 Connect cables for pressure and temperature sensor control module solenoid and power Step 3 Plug in transformer Power on interface module using external power switch Close inter...

Page 9: ...e with targets of various colors and textures for accuracy Ensure foreign objects such as stall doors and mirrors are not detected page 9 Rev 080323 PROFILE To view current profile press and release p...

Page 10: ...e adjusted from 6 54 inches Exit adjusts the amount of time an object must not be detected before the valve considers the user to have exited The range can be adjusted from 0 15 seconds Run adjusts th...