I-CON COBALT Pro 3200 Series Installation Instructions Manual Download Page 2

COBALT Pro

 Wall Sensor Activated 

Concealed Flush Valve Installation Instructions

101929 : 3200 Series

I-CON  Systems,  Inc.,  for  product  support  call  1-866-730-7192  or  visit  us  online  at  support.i-con.com                           

One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents

CONCEALED SENSOR FLUSH VALVE ROUGH-INS

3220

3250

3230

3255

3235

3240

3265

3245

  21"

533

 

"L" DIM
2 34 " [70]

+ WALL

 THICKNESS

 10 12 "

267

 

1
2"[64] WALL OPENING

  10"

254

 

  4 34 "±

1

2 "

121±13

 

1" [25] IPS
SUPPLY

CENTERLINE OF FIXTURE

AND WALL SENSOR

CENTERLINE
OF SUPPLY

TOP OF FIXTURE

INSTRUCTION CUTSHEET

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-INSTRUCTIONS-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .002

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 2.5"x1.5"

CENTURY GOTHIC SIZE 5 FONT

ONE-TIME SYSTEM SETTING CHANGE

DIMENSIONS NON-IMPORTED (DRIVEN) AND DIMENSIONS (DANGLING) SET TO BLACK

SKETCH (INACTIVE) AND SKETCH (UNDEFINED) SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

  21"

533

 

"L" DIM
2 34 " [70]

+ WALL

 THICKNESS

 14 12 "

368

 

1
2"[64] WALL OPENING

  10"

254

 

  4 34 "±

1

2 "

121±13

 

1" [25] IPS
SUPPLY

CENTERLINE OF FIXTURE

AND WALL SENSOR

CENTERLINE
OF SUPPLY

TOP OF FIXTURE

INSTRUCTION CUTSHEET

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-INSTRUCTIONS-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .002

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 2.5"x1.5"

CENTURY GOTHIC SIZE 5 FONT

ONE-TIME SYSTEM SETTING CHANGE

DIMENSIONS NON-IMPORTED (DRIVEN) AND DIMENSIONS (DANGLING) SET TO BLACK

SKETCH (INACTIVE) AND SKETCH (UNDEFINED) SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

  21"

533

 

  9"

229

 

  5"

127

 

"L" DIM
2 34 " [70]

+ WALL

THICKNESS

1
2" [64] WALL OPENING

  4 34 "±

1

2 "

121±13

 

  10"

254

 

1" [25] IPS
SUPPLY

CENTERLINE
OF SUPPLY

CENTERLINE OF FIXTURE

AND WALL SENSOR

TOP OF FIXTURE

INSTRUCTION CUTSHEET

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-INSTRUCTIONS-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .002

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 2.5"x1.5"

CENTURY GOTHIC SIZE 5 FONT

ONE-TIME SYSTEM SETTING CHANGE

DIMENSIONS NON-IMPORTED (DRIVEN) AND DIMENSIONS (DANGLING) SET TO BLACK

SKETCH (INACTIVE) AND SKETCH (UNDEFINED) SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

  21"

533

 

"L" DIM

2 34 " [70]

+ WALL

 THICKNESS

  24"

610

 

  4"

102

 

1
2"[64] WALL 

OPENING

  4 34 "±

1

2 "

121±13

 

1" [25] IPS
SUPPLY

CENTERLINE OF FIXTURE

AND WALL SENSOR

CENTERLINE
OF SUPPLY

TOP OF FIXTURE

INSTRUCTION CUTSHEET

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-INSTRUCTIONS-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .002

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 2.5"x1.5"

CENTURY GOTHIC SIZE 5 FONT

ONE-TIME SYSTEM SETTING CHANGE

DIMENSIONS NON-IMPORTED (DRIVEN) AND DIMENSIONS (DANGLING) SET TO BLACK

SKETCH (INACTIVE) AND SKETCH (UNDEFINED) SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

  4"

102

 

"L" DIM
2 34 "[70]

+ WALL

THICKNESS

 13 12 "

343

 

TOP OF FIXTURE

  4 34 "±

1

2 "

121±13

 

3
4" [19] IPS
SUPPLY

CENTERLINE
OF SUPPLY

CENTERLINE OF FIXTURE

AND WALL SENSOR

1

1
2" [38] WALL OPENING

INSTRUCTION CUTSHEET

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-INSTRUCTIONS-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .002

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 2.5"x1.5"

CENTURY GOTHIC SIZE 5 FONT

ONE-TIME SYSTEM SETTING CHANGE

DIMENSIONS NON-IMPORTED (DRIVEN) AND DIMENSIONS (DANGLING) SET TO BLACK

SKETCH (INACTIVE) AND SKETCH (UNDEFINED) SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

  21"

533

 

"L" DIM
2 34 " [70]

+ WALL

 THICKNESS

  24"

610

 

1
2"[64] WALL OPENING

  4 34 "±

1

2 "

121±13

 

1" [25] IPS
SUPPLY

CENTERLINE OF FIXTURE

AND WALL SENSOR

CENTERLINE
OF SUPPLY

TOP OF FIXTURE

INSTRUCTION CUTSHEET

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-INSTRUCTIONS-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .002

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 2.5"x1.5"

CENTURY GOTHIC SIZE 5 FONT

ONE-TIME SYSTEM SETTING CHANGE

DIMENSIONS NON-IMPORTED (DRIVEN) AND DIMENSIONS (DANGLING) SET TO BLACK

SKETCH (INACTIVE) AND SKETCH (UNDEFINED) SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

  19"

483

 

  5"

127

 

"L" DIM
2 34 " [70]

+ WALL

THICKNESS

  21"

533

 

1
2" [64] WALL OPENING

  4 34 "±

1

2 "

121±13

 

1" [25] IPS
SUPPLY

CENTERLINE
OF SUPPLY

CENTERLINE OF FIXTURE

AND SENSOR PLATE

TOP OF FIXTURE

INSTRUCTION CUTSHEET

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-INSTRUCTIONS-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .002

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 2.5"x1.5"

CENTURY GOTHIC SIZE 5 FONT

ONE-TIME SYSTEM SETTING CHANGE

DIMENSIONS NON-IMPORTED (DRIVEN) AND DIMENSIONS (DANGLING) SET TO BLACK

SKETCH (INACTIVE) AND SKETCH (UNDEFINED) SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

page 2

Rev 080323

  21"

533

 

"L" DIM

2 34 " [70]

+ WALL

 THICKNESS

 14 12 "

368

 

  4"

102

 

1
2"[64] WALL

 OPENING

  4 34 "±

1

2 "

121±13

 

  10"

254

 

1" [25] IPS
SUPPLY

CENTERLINE OF FIXTURE

AND WALL SENSOR

CENTERLINE
OF SUPPLY

TOP OF FIXTURE

INSTRUCTION CUTSHEET

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-INSTRUCTIONS-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .002

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 2.5"x1.5"

CENTURY GOTHIC SIZE 5 FONT

ONE-TIME SYSTEM SETTING CHANGE

DIMENSIONS NON-IMPORTED (DRIVEN) AND DIMENSIONS (DANGLING) SET TO BLACK

SKETCH (INACTIVE) AND SKETCH (UNDEFINED) SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

Summary of Contents for COBALT Pro 3200 Series

Page 1: ...materials are free from defects and are made to withstand normal use when installed properly Products have the following warranty periods 3 years for COBALT COBALT Pro and COBALT Connect faucets and f...

Page 2: ...KETC SET P SET P 21 533 L DIM 2 3 4 70 WALL THICKNESS 24 610 4 102 2 1 2 64 WALL OPENING 4 3 4 1 2 121 13 1 25 IPS SUPPLY CENTERLINE OF FIXTURE AND WALL SENSOR CENTERLINE OF SUPPLY TOP OF FIXTURE INST...

Page 3: ...ENGTH TO 0 1 IN ANNOTATION AND DIMENSIONING TEXT SHOULD BE ALL CAPS DUAL DIMENSION MEASUREMENT MILLIMETER SHOULD MATCH THE FRACTIONAL DISPLAY INCHES TEMPLATE INFORMATION PAGE SIZE 2 5 x1 5 CENTURY GOT...

Page 4: ...ded adapter to water supply pipe Step 3 Apply sealing compound to threaded adapter Tighten control stop onto threaded adapter using a smooth jaw wrench Step 4 Turn adjustment wheel on control stop CLO...

Page 5: ...ert flush valve tailpiece into control stop Step 3 Assemble vacuum breaker tube and spud escutcheon assemblies as shown NOTE The vacuum breaker tube may need to be cut to fit properly If using scored...

Page 6: ...ottom of flush valve cap assembly Place flush valve cap assembly onto flush valve body Step 3 Tighten locking ring by hand to flush valve body SENSOR PLATE INSTALLATION Step 1 Loosen set screw on plat...

Page 7: ...AY TO VERTICAL SET BENT LEADER LENGTH TO 0 1 IN ANNOTATION AND DIMENSIONING TEXT SHOULD BE ALL CAPS DUAL DIMENSION MEASUREMENT MILLIMETER SHOULD MATCH THE FRAC TEMPLATE INFORMATION PAGE SIZE 3 x3 CENT...

Page 8: ...e interface box Step 2 Connect cables for pressure and temperature sensor control module solenoid and power Step 3 Plug in transformer Power on interface module using external power switch Close inter...

Page 9: ...e with targets of various colors and textures for accuracy Ensure foreign objects such as stall doors and mirrors are not detected page 9 Rev 080323 PROFILE To view current profile press and release p...

Page 10: ...e adjusted from 6 54 inches Exit adjusts the amount of time an object must not be detected before the valve considers the user to have exited The range can be adjusted from 0 15 seconds Run adjusts th...

Reviews: