I-CON COBALT Pro 3200 Series Installation Instructions Manual Download Page 1

COBALT Pro

 Wall Sensor Activated 

Concealed Flush Valve Installation Instructions

101929 : 3200 Series

I-CON  Systems,  Inc.,  for  product  support  call  1-866-730-7192  or  visit  us  online  at  support.i-con.com                           

One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents

• All plumbing should be installed according to applicable state

 

and local codes and regulations.

Before installation of the I-CON flush valve, ensure the water

 

closet or urinal fixture, drain line, and water supply line are

 

properly installed.

Water supply lines must be sized to allow for appropriate water

 

flow for each fixture.

Flush all water supply lines of any debris before making an

y

connections. 

• Do not use pipe sealant or plumbing grease on any components

or couplings, with the exception of the control stop inlet.

• A smooth jaw or strap wrench should be used for installation

to prevent damage to the finish of the I-CON flush valve and

components.

• Check to ensure the “L” dimension specified on the flush valve

packaging is correct for your application. “L” Dimension formula

is provided below.

“L” Dimension = Wall Thickness (to the nearest whole inch)

+ 2-3/4”

The I-CON flush valve is designed to operate at water pressures

ranging from 15 to 100psi (103 to 689kPa). The fixture type

determines the minimum pressure required for the valve. Most

low-consumption water closets are designed to operate with a

minimum flowing water pressure of 25psi (172kPa).

CONCEALED SENSOR FLUSH VALVES

TOOLS NEEDED

PRIOR TO INSTALLATION

page 1

LIMITED WARRANTY

3220

3265

3230

I-CON Systems, Inc. (I-CON) warrants that its commercial

manufactured products are made of first-class materials, are

free from defects, and are made to withstand normal use when

installed properly. Products have the following warranty periods:

3 years for COBALT®, COBALT Pro™, and COBALT Connect™

faucets and flush valves and I-CON EDGE® gateways. 1 year for

all other products and decorative finishes. The warranty period

begins on the date of purchase.
Products should be sent to I-CON at the customer’s expense. 

I-CON will take a reasonable amount of time to determine if the

product is defective and whether it will be repaired or replaced.

During the warranty period, items will either be (1) repaired

at no charge using new replacement parts or (2) replaced with

either a new similar product or one manufactured from new

or serviceable used parts that are, at minimum a functional

equivalent to the original. The course of action will be

determined at I-CON’s discretion. Replacement products that

are installed according to the instructions provided by I-CON will

assume the remaining warranty of the original product.

The limited warranty is only applicable to the product’s materials

and workmanship. No claims for labor, transportation, or other

incidental or consequential costs will be allowed. No extended

warranties are available. THE SOLE AND EXCLUSIVE REMEDY

FOR ANY DEFECTIVE PRODUCT IS LIMITED TO REPAIRING OR

REPLACING THE DEFECTIVE PRODUCT. Before installing and

using products, the purchaser is responsible for determining the

products’ suitability and assumes all risks and liabilities related

to the product.
This warranty only applies to persons and organizations that 

purchase I-CON products directly from I-CON or an authorized 

I-CON representative for the purpose of resale. This warranty

does not apply to the life of batteries or other consumables.

Rev 080323

Allen Wrench

Flat Head Screwdriver

Phillips Screwdriver

Smooth Jaw 

Wrench

T15H

Screwdriver

Pipe Solder

Pipe Cutter

Summary of Contents for COBALT Pro 3200 Series

Page 1: ...materials are free from defects and are made to withstand normal use when installed properly Products have the following warranty periods 3 years for COBALT COBALT Pro and COBALT Connect faucets and f...

Page 2: ...KETC SET P SET P 21 533 L DIM 2 3 4 70 WALL THICKNESS 24 610 4 102 2 1 2 64 WALL OPENING 4 3 4 1 2 121 13 1 25 IPS SUPPLY CENTERLINE OF FIXTURE AND WALL SENSOR CENTERLINE OF SUPPLY TOP OF FIXTURE INST...

Page 3: ...ENGTH TO 0 1 IN ANNOTATION AND DIMENSIONING TEXT SHOULD BE ALL CAPS DUAL DIMENSION MEASUREMENT MILLIMETER SHOULD MATCH THE FRACTIONAL DISPLAY INCHES TEMPLATE INFORMATION PAGE SIZE 2 5 x1 5 CENTURY GOT...

Page 4: ...ded adapter to water supply pipe Step 3 Apply sealing compound to threaded adapter Tighten control stop onto threaded adapter using a smooth jaw wrench Step 4 Turn adjustment wheel on control stop CLO...

Page 5: ...ert flush valve tailpiece into control stop Step 3 Assemble vacuum breaker tube and spud escutcheon assemblies as shown NOTE The vacuum breaker tube may need to be cut to fit properly If using scored...

Page 6: ...ottom of flush valve cap assembly Place flush valve cap assembly onto flush valve body Step 3 Tighten locking ring by hand to flush valve body SENSOR PLATE INSTALLATION Step 1 Loosen set screw on plat...

Page 7: ...AY TO VERTICAL SET BENT LEADER LENGTH TO 0 1 IN ANNOTATION AND DIMENSIONING TEXT SHOULD BE ALL CAPS DUAL DIMENSION MEASUREMENT MILLIMETER SHOULD MATCH THE FRAC TEMPLATE INFORMATION PAGE SIZE 3 x3 CENT...

Page 8: ...e interface box Step 2 Connect cables for pressure and temperature sensor control module solenoid and power Step 3 Plug in transformer Power on interface module using external power switch Close inter...

Page 9: ...e with targets of various colors and textures for accuracy Ensure foreign objects such as stall doors and mirrors are not detected page 9 Rev 080323 PROFILE To view current profile press and release p...

Page 10: ...e adjusted from 6 54 inches Exit adjusts the amount of time an object must not be detected before the valve considers the user to have exited The range can be adjusted from 0 15 seconds Run adjusts th...