Miscellaneous setup
From the drop-down menu you can select: type and category of Tank, battery type and number of cells, enabling the extended signalling
(Flasher) through the IR receiver led. Extended signalling include alerts for low battery, reload, low battery level, current threshold
exceeded, excessive module temperature. If these reports are disabled the standard signals are still present.
In case of radio sticks neutral position stability issue is possible via this control to set a
"dead zone" in which any fluctuations of the value is not considered.
In case of problems of stability in the neutral position of the turret rotation is possible
to set, as for the previous option, a percentage offset within which any fluctuations are
not considered.