6. Caution

Environment

1) The machine can perform in environment in dry condition with a dampness level of max 90%.
2) Ambient temperature is between 10 to 40

o

C.

3) Avoid welding in sunshine or rain.
4)  Do not use the machine in environment where condition is polluted with conductive dust on the air or 

corrosiveness gas on the air

5) Avoid gas welding in the environment of strong airflow.

Safety norms

The welding machine is equipped with protection circuit of over voltage, current and heat. When voltage and 
output current and temperature of machine are exceeding the rate standard, welding machine will stop work-
ing automatically. Because it will be damage to welding machine, user must pay attention as follows.3

1)  The working area is adequately ventilated!

      

The welding machine is powerful machine, when it is being operated, it generated high currents, and natu-
ral wind will not make machine cool enough. So there is a fan in machine to cool down machine. Make sure 
the intake is not in block or covered, it is 0.3 meter from welding machine to objects of environment. User 
should make sure the working area is adequately ventilated. It is important for the performance and the 
durability of the machine.

2)  Do not overload!

 

        

The operator should remember to watch the max duty current (Response to the selected duty cycle). 
Keep welding current from exceeding max duty cycle current. Over-load current will damage and burn up 
machine.

3)  No over voltage!

 

        

Power voltage can be found in table of main technical data. Automatic compensation circuit of voltage will 
assure that welding current remain in allowable range. If power voltage exceeds limited range, it is damage 
to components of machine. The operator should understand the situation and take preventive measures.

4)

  There is a grounding screw behind welding machine and there is grounding marker on it. Mantle must 

be grounded reliable with cable which section is over 6 square millimeter in order to prevent from static 
electricity and leaking.

(5)

  If welding time exceeds limited duty cycle, welding machine will stop working for protection. Because 

machine is overheated, temperature control switch is on “ON” position and the indicator light is red. In this 
situation, you don’t have to pull the plug in order to let the fan cool the machine. When the indicator light is 
off, and the temperature goes down to the standard range, it can weld again. should be fully prepared for 
protection.

Summary of Contents for HYTIG-160

Page 1: ...DC INVERTER TIG WELDER TIG 160 200 User Manual For Your Safety Read and understand this manual before use Keep this manual for future reference EN...

Page 2: ...this welder therefore some parts of this welder may be changed in order to achieve the better quality but the main functions and operations will not be alternated and changed Your understanding would...

Page 3: ...g 160 200 Safety General Description Main Parameters Operation Control and Description Installation Debugging and Operation Caution Maintenance Troubleshooting Exploded Drawing 2 4 4 5 6 7 8 9 11 Tabl...

Page 4: ...et gloves clothes Make sure that you are insulated from the ground and work piece Make sure that your working position is safe Smoke gas may be harmful to health Keep the head away from smoke and gas...

Page 5: ...e center of your supplier to seek professional help if you still cannot fully understand after reading the manual or still cannot solve the problem according to the manual Safe use of the welding torc...

Page 6: ...different dynamic characteristics and it can even be adjusted specially to make arc softer and also harder TIG welding machine is easy for arc initiation and has the functions of arc initiation curren...

Page 7: ...ce for some time before arc has been extinguished 4 Set suitable welding current and make sure welding current is adequate to thickness of work piece and process demand 5 It is 2 4 mm from welding tun...

Page 8: ...ture When using MMA welding Make sure the cable holder and fastening plug have been connected with the ground Put the fastening plug into the fastening socket at the polarity and fasten it clockwise W...

Page 9: ...area is adequately ventilated It is important for the performance and the durability of the machine 2 Do not overload The operator should remember to watch the max duty current Response to the selecte...

Page 10: ...tored in dry environment Correct Disposal of this product This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the...

Page 11: ...n lower welding quality B Arc striking is difficult and easy to pause 1 Make sure quality of tungsten electrode is high 2 Grind end of the tungsten electrode to taper If tungsten electrode is not grin...

Page 12: ...o welding piece 3 Output terminal of positive electrode or torch electrify loosens from inter machine Abnormal indicator is not lit sound of HF arc striking cannot be heard wiping welding can strike a...

Page 13: ...160 200 13 Bottom 14 Cover 15 Front panel 16 Side shield plate 17 Radiator left 18 Radiator right 19 Cross beam 20 Gas interface 21 Insulation board on top PCB 22 Insulation board on bottom PCB 23 Bra...

Page 14: ...INVERTER TIG WELDER MODEL TIG 160 200 Satisfies the requirements of the Council Directives EC Low voltage directive 2014 35 EU EC Directive of Electromagnetic Compatibility 2014 30 EU RoHS Directive...

Page 15: ......

Page 16: ...HYUNDAI Corporation 25 Yulgok ro 2 gil Jongno gu Seoul 03143 Korea Post Code 03143 82 2 390 1114 www hyundaicorp com Copyright 2016 HYUNDAI Corporation All rights reserved Made in P R C...

Reviews: