1.5.3

 

 

 

 

1.5.4

 

Respiratory protective equipment should be used when in an unventilated area. 

1.5.5

 

When defueling always use a propriety fuel retriever. 

1.5.6

 

Always carry fuel in the correct and clearly marked container. 

 

1.6

 

Additional Safety guidelines. 

1.6.1

 

To prevent fire. 

1.6.1.1

 

Never add fuel to the fuel tank whilst the engine is running. Wipe away any spilt fuel or oil 

with a clean cloth before operating. Keep explosives and any other flammable products 

away from the machine at all times. 

1.6.1.2

 

To prevent fire and to provide adequate ventilation, keep the machine at least one metre 

away from buildings and other equipment during operation. 

1.6.1.3

 

Operate the machine on level ground. - Do not place the machine indoors whilst the 

engine is still hot. 

1.6.1.4

 

To prevent inhaling exhaust fumes. 

1.6.1.5

 

Exhaust gas contains poisonous carbon monoxide which is harmful to health and can kill. 

1.6.1.6

 

For this reason, never use the machine in a closed area or areas with poor ventilation. 

1.6.2

 

To prevent burns. 

1.6.2.1

 

The muffler and the engine body becomes very hot whilst the engine is running or just 

after running. 

1.6.2.2

 

To prevent any burns, do not touch these parts during these times. 

1.6.2.3

 

Careless or improper use of any water pump may cause serious or fatal injury. 

1.6.3

 

If you are unsure how to use the machine you must read all of this manual and get your dealer 

to demonstrate its use. 

1.6.4

 

Observe all applicable local safety regulations and standards. 

1.6.5

 

Children should never be allowed to use this machine. 

1.6.6

 

Bystanders, especially children, and animals should not be allowed in the area where a water 

pump is in use. 

1.6.7

 

The operator is responsible for avoiding injury to third parties and damage to their property. 

1.6.8

 

Do not lend or rent your water pump without the owner's manual. Be sure that anyone who 

uses your water pump fully understands the information contained in this manual. 

1.6.9

 

You must be fit to work with a water pump. 

1.6.10

 

You should not operate the machine if you are not well or physically unable. if you get tired, 

take a break in good time. 

1.6.11

 

Do not operate the blower/vacuum if you are under the influence of any substance (drugs, 

alcohol, etc.) which might impair vision, dexterity or judgment. 

1.6.12

 

Only attachments supplied are expressly approved for use with your specific model are 

authorised. 

1.6.12.1

 

Other attachments must not be used because of the increased risk of accidents. 

1.6.12.2

 

No liability will be accepted for personal injury and damage to property caused while 

using unauthorised attachments. 

1.6.13

 

Before starting check the following points: 

1.6.13.1

 

The choke lever must move freely. 

1.6.13.2

 

The stop switch must move easily to "OFF" 

1.6.14

 

Tightness of spark plug cap - if cap is loose, sparks may occur and ignite the escaping fuel 

vapours. 

1.7

 

Starting. 

1.7.1

 

For safety reasons, this water pump must not be used in potentially explosive atmospheres. 

1.7.2

 

Start the engine at least 3 m (10 ft.) from the fueling spot, outdoors only. 

1.7.3

 

To reduce the risk of breathing toxic fumes, never start or run your unit in confined spaces. 

1.7.4

 

Place the machine on firm level ground in an open area. 

1.7.5

 

Make sure you have good balance and secure footing and hold the unit securely. 

1.7.6

 

DO NOT allow other persons to be near the running unit - even when starting. For specific 

Rev 6 - 10/11/2015

Summary of Contents for HY50

Page 1: ...WATER TRASH CHEMICAL PUMPS Models HY50 HYC50 HY80 HYT80 User Manual...

Page 2: ...in this manual are correct and relevant at the time of publishing We reserve the right to make changes to this manual at any time without prior notice Our range of water pumps are designed to give sa...

Page 3: ...OPERATION INSPECTION 10 12 4 ASSEMBLY OPERATION 12 14 5 STARTING STOPPING THE ENGINE 15 16 6 MAINTENANCE 17 19 7 STORAGE 19 8 TROUBLESHOOTING 20 9 WIRING DIAGRAM 21 10 SPECIFICATIONS 22 11 DECLARATIO...

Page 4: ...sing the machine 1 2 2 Some or all of the following PPE Warning Signs and symbols may appear throughout this manual and you must adhere to their warning s Failure to do so may result in personal injur...

Page 5: ...oxide poisoning 1 3 4 1 Get fresh air immediately by opening doors and windows turning off the machine and leaving the affected area 1 3 4 2 See your doctor immediately or go to hospital let them know...

Page 6: ...ls should not be allowed in the area where a water pump is in use 1 6 7 The operator is responsible for avoiding injury to third parties and damage to their property 1 6 8 Do not lend or rent your wat...

Page 7: ...n the owner s manual 1 7 7 Take care in slippery conditions such as on ice in wet or snow and on slopes or uneven ground 1 7 8 Watch out for obstacles such as roots ditches holes or rubbish which coul...

Page 8: ...Rev 6 10 11 2015...

Page 9: ...om the engine muffler and recoil starter 3 3 3 Look for any signs of damage 3 3 4 Check that all nuts bolts screws hose connectors and clamps are tightened 3 4 Suction discharge hose checks 3 4 1 Chec...

Page 10: ...roach to each model 3 6 3 Undo air filter cover Allen screw wing nut 1 and remove cover 3 6 4 Remove air filter cartridge 2 3 6 5 Remove inspect and clean foam element 3 all models Clean by washing in...

Page 11: ...and how to operate it properly and how to use the controls 4 1 2 Before operating the water pump for the first time please make sure you have read the SAFETY Instructions and PRE OPERATION inspection...

Page 12: ...prevent water leakage 4 4 Connecting the hose strainer 4 4 1 Install the supplied hose strainer 1 provided with the pump on the end of the suction hose 3 not supplied and secure it with a hose clamp 2...

Page 13: ...7 4 DO NOT unscrew the priming plug during operation of the water pump 4 8 Using at high altitudes 4 8 1 At high altitude the standard carburetor air fuel mixture will be excessively rich 4 8 2 As a...

Page 14: ...engine is cold move the choke lever 2 to the CLOSED position 5 1 5 Adjust the throttle lever 3 and to change the speed of the engine which will change the flow rate of water For a higher flow rate set...

Page 15: ...s stopped turn the fuel valve lever 1 off 5 2 3 After use remove the pump drain plug 6 component locations section 2 and drain the pump chamber 5 2 4 Remove the filler cap 8 component locations sectio...

Page 16: ...he engine is warm Warm oil drains quickly and completely Be careful to avoid injury from hot oil 6 3 2 Place a suitable container 4 below the engine to catch the used oil then remove the oil filler ca...

Page 17: ...the air filter will need to be cleaned more regularly than specified in the maintenance schedule 6 6 Spark plug service Using the wrong type of spark plug can result in engine damage 6 6 1 Recommended...

Page 18: ...2 of the carburetor float bowl 1 and sediment cup 6 and O ring 5 then open the fuel lever 4 7 2 2 Completely drain the fuel from the carburetor and fuel tank then replace the sediment cup and drain p...

Page 19: ...primed Prime pump Check suction hose Hose collapsed cut or punctured Replace hose Strainer not completely under water Sink strainer and end of suction hose completely under water Air leak at connector...

Page 20: ...9 WIRING DIAGRAM Rev 6 10 11 2015...

Page 21: ...rive Direct drive Start Method Recoil Recoil Recoil Recoil Intake mm 2 50 2 50 3 80 3 80 Outlet inch 2 50 2 50 3 80 3 80 Maximum Flow Rate L min 500 500 750 917 Impeller Type Cast Iron Nylon Fiberglas...

Page 22: ...s that the Hyundai water pumps conform to the following CE directives 2006 42 EC Machinery directive 2004 108 EC EMC directive 73 23 EC The low voltage directive 97 68 EC NRMM emissions directive 11 2...

Page 23: ...tal address Genpower Limited Isaac Way Pembroke Dock Pembrokeshire SA72 4RW UK Telephone contact number Office 44 0 1646 687880 Email contact service genpower co uk Web site www hyundaipowerequipment...

Page 24: ...www hyundaipowerequipment co uk GENPOWER LTD Isaac Way London Road Pembroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerequipment co uk...

Reviews: