2.2.21.

 

Use only genuine replacement parts. 

2.2.21.1.

 

Replacement parts 

that are 

not original may void your warranty and 

can lead

 to malfunction and resulting injuries. Genuine parts are available 

from

 your dealer. 

 

2.2.22.

 

DO NOT modify the compressor. 

2.2.22.1.

 

DO NOT modify the compressor. Always contact the authorized 

service centre 

for 

any repairs. Unauthorized modification may not only 

impair the compressor performance but may also result in accident or 
injury to repair personnel who DO NOT have the required knowledge and 
technical expertise to perform the repair operations correctly. 

2.2.23.

 

Turn off the pressure switch when the compressor is not used. 

2.2.23.1.

 

When the compressor is not used, turn the knob of the pressure 

switch off, disconnect it from the power source and open the drain cock to 
discharge the compressed air from the air tank. 

2.2.24.

 

NEVER touch hot surface. 

2.2.24.1.

 

To reduce the risk of burns, DO NOT touch tubes, heads, cylinder and 

motors. 

2.2.25.

 

DO NOT 

direct the 

air stream 

toward any part to anyones face or body parts.

 

2.2.25.1.

 

Risk of injury, DO NOT direct air stream at persons or animals. 

2.2.26.

 

Drain tank. 

2.2.26.1.

 

Drain tank daily or after 4 hours of use. 

2.2.26.2.

 

Open drain fitting and tilt compressor to empty accumulated water. 

2.2.27.

 

DO NOT stop compressor by pulling out the plug. 

2.2.27.1.

 

Use the “auto/off” knob of pressure switch. 

2.2.27.2.

 

Use only recommended air handling parts acceptable for pressure not 

less than 125 psi (8.6 bar) 

2.2.27.3.

 

Risk of bursting. Use only recommended air handling parts acceptable 

for pressures not less than 125 psi (8.6 bar). 

2.2.28.

 

Replacement parts. 

2.2.28.1.

 

When servicing use only genuine Hyundai replacement parts, all 

repairs should be conducted only by authorized service centre. 

2.2.29.

 

Earthing/Grounding instructions. 

2.2.29.1.

 

This compressor should be earthed/grounded while in use to protect 

the operator from electric shock. The compressor is equipped with a three 
core cable and three-prong grounding type plug to fit the proper 
grounding type receptacle. 

2.2.29.2.

 

The green (or green and yellow) conductor in the cable is the 

earthing/grounding wire. NEVER connect the green (or green and yellow) 
wire to a live terminal. 

2.2.30.

 

Extension cable. 

2.2.30.1.

 

Use only three core cables that have three-prong grounding type 

plugs and three-pole receptacles that accept the compressor’s plug. 
Replace or repair damaged cable. Make sure your extension cable is in 
good condition. When using an extension cable, be sure to use one heavy 

Page 8

Original

Summary of Contents for HY3200S

Page 1: ...ELECTRIC AIR COMPRESSOR Model HY3200S User Manual...

Page 2: ...Page 2 Original...

Page 3: ...6 16 17 17 1 SAFETY 2 MACHINE SPECIFIC SAFETY 3 PART LOCATIONS SPECIFICATIONS 4 STORING UNPACKING SITING OPERATION 5 MAINTENANCE 6 TROUBLESHOOTING 7 PRODUCT DISPOSAL 8 DECLARATIONS of CONFORMITY 9 CON...

Page 4: ...re to their warning s Failure to do so may result in personal injury to yourself or those around you The FOLLOWING safety notes will help avoid or reduce risk of injury or death Indicates a hazard whi...

Page 5: ...our hands and fingers Seek medical attention immediately if any of the above symptoms should occur 1 3 Noise 1 3 1 The operating noise of the machine can damage your hearing Wear hearing protection su...

Page 6: ...any parts 2 2 6 Avoid unintentional starting 2 2 6 1 DO NOT carry the compressor while it is connected to its power source or when the air tank is filled with compressed air Be sure the knob of the pr...

Page 7: ...or according to the instructions provided herein Never allow the compressor to be operated by children individuals unfamiliar with its operation or unauthorized personnel 2 2 16 Keep all screws bolts...

Page 8: ...daily or after 4 hours of use 2 2 26 2 Open drain fitting and tilt compressor to empty accumulated water 2 2 27 DO NOT stop compressor by pulling out the plug 2 2 27 1 Use the auto off knob of pressu...

Page 9: ...pressor unit 2 Belt guard 3 Electric motor 4 Power Pressure switch 5 Pressure gauge 6 Direct compressed air outlet 7 Feet 8 Condensate drain valve 9 Pressure relief valve 10 Oil level sight glass 11 O...

Page 10: ...from dust by covering it with a suitable cover If the compressor is not going to be used for long periods the oil should be replaced and its operational efficiency should be checked 4 2 Unpacking siti...

Page 11: ...ports not supplied 4 2 7 If the compressor is to be mounted on brackets or a shelf top you MUST make sure it cannot fall by securing it in a suitable way 4 2 8 To make sure that the compressor has ade...

Page 12: ...hine is operating 4 3 1 6 This compressor is supplied with a thermal breaker located on the side of the terminal box onto of the motor When the breaker is tripped wait for a few minutes and then press...

Page 13: ...0 5 1 3 There is NO pressure in the air tank 5 2 After every 50 hours of duty 5 2 1 We advise you to dismantle the air filter 1 and clean the filtering element by blowing it through with compressed ai...

Page 14: ...r is filled with synthetic oil 5 4 2 We recommend a full change of oil in the pumping element within the first 100 hours of duty 5 4 3 Unscrew the oil drain plug 1 on the housing cover allow all the o...

Page 15: ...or 6 1 6 DO NOT place inflammable objects near the compressor 6 1 7 During down times turn the pressure switch to position 0 OFF 6 1 8 Never aim the air jet at people or animals 6 1 9 DO NOT transport...

Page 16: ...heck valve take the following actions 6 2 1 1 Isolate compressor from the electrical supply 6 2 1 2 Discharge all pressure from the tank 6 2 1 3 The valve is located at the opposite end from the power...

Page 17: ...ical Electronic Equipment WEEE Certain products contain waste which should not be disposed of in your domestic waste You MUST recycle WEEE in accordance with your local authority or recycling centre 7...

Page 18: ...wer Ltd Isaac Way London Road Pembroke Dock Pembrokeshire SA72 4RW UK 9 2 TELEPHONE 44 0 1646 687880 9 3 FAX 44 0 1646 686198 9 4 TECHNICAL E MAIL service genpower co uk 9 5 WEBSITE www hyundaipowereq...

Page 19: ...Page 19 Original...

Page 20: ...www hyundaipowerequipment co uk GENPOWER LTD Isaac Way London Road Pembroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerequipment co uk...

Reviews: