11
3.17
This range of generators adopt a floating earth configuration which means that the
Neutral of the alternator is not connected to the Earth of the machine.
3.18
It is therefore important that you only use the generator to supply equipment in the
following class combinations:
One or more of CLASS II equipment
Only ONE item of CLASS I equipment
One or more of CLASS II equipment and only ONE item of CLASS I equipment
3.19
CLASS I equipment has a GREEN/YELLOW earth wire connected inside the plug.
3.20
CLASS II equipment DOES NOT have GREEN/YELLOW earth wire connected
inside the plug.
3.21
CLASS II equipment will have the following symbol embossed or printed
on the casing.
WARNING
NEVER start or stop the engine with electrical devices plugged in to the power outlets
and devices turned on.
Unplug all electrical loads from the unit’s power outlets or make sure that the main
breaker is OFF (down) position, before starting the engine.
WARNING
If running the generator on LPG you
MUST
ensure the petrol fuel tank has been
completely drained.
4.0
Move the fuel selector switch to the petrol position.
4.1
Turn the fuel tap to the ON position.
4.2
Turn the ignition switch to the ON position.
4. STARTING THE MACHINE
RECOIL START