Leakage / Drainage - 3/5
Case-7
Factor
Water leaks caused by upwarded drain hose along the wall-through hole and clogged drain
hose with water.
Drain piping and ending.
Troubles &
Causes
Defect Details
Guidelines
■
The wall-through hole should be downward.
■
Don't make drain hose clogged with water.
2. Clogged drain hose with water.
1. Upwarded drain hose along the wall-through
hole.
Downward
Arrange gap
Drainage can't flow down
across the wall.
Drainage can't flow
down along the
hose.