HRH-L093NDC-W HRH-L093NDC-S
Air Conditioner Service Manmual
Connection
Pipe
Length (m)
Max Distance
Height (m)
Net Weight /Gross Weight (kg)
32/36
Gas Pipe (mm)
Ф
9.52(3/8)
Outer Diameter
Liquid Pipe (mm)
Φ
6(1/4'')
Gas additional charge(g/m)
20
Length (m)
3
Refrigerant Charge (kg)
1002
Permissible Excessive Operating Pressure for
theDischarge Side(MPa)
4.5
Dimension of Package (L/W/H)( mm)
863x590x361
Dimension (W/H/D) ( mm)
760x552x256
Sound Power Level dB (A) (H/M/L)
Sound Pressure Level dB (A) (H/M/L)
52
Permissible Excessive Operating Pressure for
theSuction Side(MPa)
1.9
Fan Type
Axial fan
Moisture Protection
IP25
Isolation
I
Climate Type
T1
Defrosting Method
Auto defrost
Fan Diameter (mm)
φ
408×132
Coil length (l) X height (H)Xcoil width (L)
756x510x25.4
Air Flow Volume of Outdoor Unit(m3/h)
2340
Fan Motor Capacitor (
μ
F)
2.5
Fan Motor RLA(A)
0.45
Output of Fan Motor (W)
31
Fan Motor Speed (rpm)
860
Throttling Method
Capillary
Rows-Fin Gap(mm)
2-1.5
Pipe Diameter (mm)
Φ
7
Condenser
Hydrophilic aluminum fin-copper tube
Working Temp Range (ºC)
18-44
Starting Method
Capacitor
Compressor Power Input(W)
705±5%
Compressor RLA(A)
4.75±5%
Outdoorunit
Model of Outdoor Unit
L.R.A. (A)
N.A
Compressor Type
Rotary
Compressor Model
DA89X1C-20FZ3
Overload Protector
INT01L-4639
Compressor Manufacturer/trademark
GMCC
Product Code
/
15
Summary of Contents for HSH-I073NBE
Page 18: ...Louver Pipes and Power Air Conditioner Service Manual 18 ...
Page 19: ...Air Conditioner Service Manmual 19 ...
Page 22: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL HSH I183NBE INDOOR UNIT OUTDOOR UNIT 22 ...
Page 23: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL HSH I243NBE INDOOR UNIT OUTDOOR UNIT 23 ...
Page 26: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL INDOOR UNIT OUTDOOR UNIT 26 ...