2.2   Notice 

·

 

Installing  solar  photovoltaic  systems  requires  specialized  skills  and  knowledge,  and  should  only  be 

performed by qualified persons. 

·

 

Each module has a junction box for permanent cable connection. HHIGE can provide customers with 

fitted  cables  for  easy  installation.  Installers  should  secure  the  safe  installation  status  including  all 

electrical hazards. 

 

2.3                     

·

 

Installers should secure the installation status, without limitation, including the risk of electric shock. 

·

 

Back sheet of PV module should be kept safe from any damage or scratch to prevent mechanical or 

electric shock. 

·

 

Do  not  disassemble  or  remove  any  part  of  a  PV  module  or  such  actions  may  cause  electric  shock, 

fire or damage. 

·

 

Keep  safety  regulations  for  all  components  used  in  the  system,  including  wiring  and  cables, 
connectors, charging regulators, inverters, storage batteries and rechargeable batteries, etc. 

 

2.4                       

·

 

Before  installation,  prevent  the  module  from  exposure  to  direct  sunlight  or  other  light  source.  (If 

modules  are  exposed  directly  to  sunlight  without  connection, each  module  generates  over  DC  30V, 

which is potentially hazardous.) 

·

 

Modules  are  heavy.  Be  sure  to have  more  than  two  persons  with anti-slip  gloves  on  carry  each  PV 

module. Do not throw and drop PV modules. 

·

 

Do not sit, stand, step, walk and/or jump on the module, including the frames. 

·

 

Do not drop or place objects on the modules. Do not place excessive loads on the modules or twist 

the module frame. 

·

 

All installation equipment and PV modules must be kept in dry condition during installation. 

·

 

Check  the  current  and  the  voltage  before  connecting  the  line.  There  is  potential  hazard  in  case  of 

higher voltage in series connection and higher current in parallel connection. 

·

 

All  PV  modules  must  be  earthed  by  using  earth  device.  Safety  check  for  all  other  parts  of  systems 

should be finished before installation to prevent any electric hazard. 

·

 

Do not use any damaged PV module, where it may cause fire, electric shock or injury. 

·

 

Do not focus light on a PV module, where it may cause fire and damage. 

·

 

Do  not  touch  live  parts  of  wires,  cables,  connectors,  or  junction  boxes,  in  order  to  prevent  electric 
shock  and  injury.  Be  sure  the  circuit  breaker  is  off  if  it’s  applicable.  Always  use  appropriate  safety 
equipment. (Insulated tools, insulating gloves, etc.) 

·

 

Do not re-arrange bypass diodes, where it may cause electric shock and injury. 

·

 

Do not disconnect the cable when the load to module is engaged. 

·

 

Check applied Class for module after installing the module. 

·

 

Do not remove any labels. 

 

 

Summary of Contents for HIS-M210RF

Page 1: ...gions may have different regulations for solar PV installations In this manual hereafter IEC only is used to refer to regions where IEC standard applies e g Europe Middle East most of Asia Pacific countries UL only is used to refer to regions where UL standard applies e g United States Canada all other references are global 2 General Information This manual provides the installation information fo...

Page 2: ...ule generates over DC 30V which is potentially hazardous Modules are heavy Be sure to have more than two persons with anti slip gloves on carry each PV module Do not throw and drop PV modules Do not sit stand step walk and or jump on the module including the frames Do not drop or place objects on the modules Do not place excessive loads on the modules or twist the module frame All installation equ...

Page 3: ...on Do not use different types of PV module in a same module array Abide by the safety regulations for all other components within the total system 2 7 UL Listing Information The following requirements should be considered carefully during installation to meet UL requirements It is necessary to use single or non hollowed copper wire For module connection it is necessary to use irradiation proof cab...

Page 4: ...turally disappear over time or can be reduced by following the washing guidelines in Section 7 1 Do not install PV modules horizontally Horizontal installation can cause performance drop of PV modules HHIGE recommends mounting modules at a 12 5 tilt or greater 3 3 General Operation Condition PV modules will be operated under General Operation Condition GOC Do not install PV module at site beyond G...

Page 5: ...stalled in sulfurous area near sulfurous volcano and sulfurous spring If PV modules are installed near factory or plant area they can be polluted by fumes and the pollution may not be cleaned Thus the installer should consider and check the installation area and the distance from factory or plant area If PV modules are installed in damp environments the installer should check the installation area...

Page 6: ...2 Korea 1100 430 252 948 652 4 x Ø 7 L11 MOUNTING HOLES GROUND MARK 4x Ø4 2 GROUND HOLES 185 20 145 20 1200mm 4mm CABLE AND CONNECTOR 1200mm 4mm CABLE AND CONNECTOR 2 J BOX L A B E L MOUNTING HOLE MOUNTING HOLE MOUNTING HOLE 430 GROUND HOLE GROUND HOLE GROUND HOLE 10 4 Ø 7 SLOT THRU 11 7 DETAIL A Picture 2 HiS SxxxRI TI MxxxRI TI Hole Position Picture 3 Installation Method using bolt nut ...

Page 7: ...s Office Bundang First Tower 55 Bundang ro Jongno gu Seongnam si Gyeonggi do 13591 Korea Factory 313 Soi ro Soi myeon Eumseong gun Chungcheongbuk do 369 872 Korea Picture 4 Mounting Hardware Picture 5 Installation Method using clamping ...

Page 8: ...1 000 or 1 500 Cell quantity in series pcs 54 Bypass diodes pcs 3 Cell Type Poly crystalline Silicon Cell Application Safety Class Class A Class II Fire rating Class C IEC Type 1 or Type 2 UL Electrical Characteristics HiS SxxxRF TF Mono Crystalline Si Type 3 4 Bus Bar Type 54 Cells Item HiS SxxxRF TF xxx Maximum Power Value Maximum Power at STC Pmax W 225 230 235 240 245 250 255 260 265 270 275 2...

Page 9: ...0 or 1 000 or 1 500 Cell quantity in series pcs 60 Bypass diodes pcs 3 Cell Type Poly crystalline Silicon Cell Application Safety Class Class A Class II Fire rating Class C IEC Type 1 or Type 2 UL Electrical Characteristics HiS SxxxRG TG Mono Crystalline Si Type 3 4 Bus Bar Type 60 Cells Item HiS SxxxRG TG xxx Maximum Power Value Maximum Power at STC Pmax W 265 270 275 280 285 290 295 300 305 310 ...

Page 10: ...00 or 1 000 or 1 500 Cell quantity in series pcs 72 Bypass diodes pcs 3 Cell Type Poly crystalline Silicon Cell Application Safety Class Class A Class II Fire rating Class C IEC Type 1 or Type 2 UL Electrical Characteristics HiS SxxxRI TI Mono Crystalline Si Type 3 4 Bus Bar Type 72 Cells Item HiS SxxxRI TI xxx Maximum Power Value Maximum Power at STC Pmax W 325 330 335 340 345 350 355 360 365 370...

Page 11: ... Width mm inches 998 39 3 2 0 Depth mm inches 50 1 97 40 1 57 0 3 Weight kg pounds 23 2 51 1 23 0 50 7 The specifications in the datasheet are tested under STC Under actual field conditions a photovoltaic module is likely to experience conditions that produce more current and or voltage than reported at standard test conditions There are different standards of electric safety HHIGE recommend that ...

Page 12: ...g should be connected safely in order to prevent any hazard All PV modules for one serial connection must be identical in terms of output and in types Do not connect PV modules directly in parallel without the combine box 5 2 Module Wiring System voltage should not exceed the maximum system voltage of module Refer to the table of clause 4 1 Notes on specification The maximum number of modules in p...

Page 13: ...d the like have not been evaluated for electrical conductivity or for use as grounding devices and should be used only for maintaining mechanical connections and holding electrical grounding devices in the proper position for electrical conductivity Such device where supplied with the module and evaluated through the requirements in UL 1703 may be used for grounding connections in accordance with ...

Page 14: ...ushed on the direct exit of the cable screw joint A minimum bending radius R 5 x cable diameter must be maintained The cable must be routed in a way that tensile stress on the conductor or connections is prevented Picture 8 Cable Routing 5 When connect connectors insert connector until locking hook catches the holder and clicks Pull each connector gently and make sure connectors are not disconnect...

Page 15: ... sufficient to keep the module glass surface clean For AR coating HHIGE modules utilize special materials to increase energy harvest Always use clean gloves when handling the module never touch the glass with bare hands If dirt build up becomes excessive clean the glass surface with room temperature water Do not use water with high pressure for cleaning Do not use harsh cleaning materials such as ...

Page 16: ...0 160 20 1000mm 4mm CABLE AND CONNECTOR 2 1000mm 4mm CABLE AND CONNECTOR 2 MOUNTING HOLES 2 MOUNTING HOLES 2 MOUNTING HOLES 47 325 4 x Ø 4 2 GROUND HOLES J BOX 35 0 3 30 SECTION D D 30 35 11 7 5 11 35 11 DETAIL B 8 8 Ø 7 SLOT THRU DETAIL A SECTION C C 11 800 60 360 253 954 548 8 x Ø 7 L11 MOUNTING HOLES GROUND MARK C C D D A 200 20 160 20 998 2 0 1640 2 0 420 20 J BOX 4 x Ø 4 2 GROUND HOLES GROUND...

Page 17: ... AND CONNECTOR 2 MOUNTING HOLE MOUNTING HOLE MOUNTING HOLE J BOX L A B E L 430 GROUND HOLE GROUND HOLE GROUND HOLE 50 0 3 430 20 998 2 0 1960 2 0 B 1960 2 0 998 2 0 10 4 Ø 7 SLOT THRU DETAIL B DETAIL A 35 0 50 0 SECTION C C SECTION D D 11 0 35 0 50 0 11 0 6 5 10 11 7 1100 430 252 948 652 4 x Ø 7 L11 MOUNTING HOLES GROUND MARK 4x Ø4 2 GROUND HOLES C C D D 185 20 145 20 1200mm 4mm CABLE AND CONNECTO...

Page 18: ...IS M SxxxRI TI Method 2400 Pa 5400 Pa Bolting Long Bar Clamping Clamping area Additional support bar area Additional Clamping area for slipping snow Min clamping width 2 50mm Long Bar Clamping Area L 4 L 8 Clamping Area L 4 Short Bar Clamping Area S 4 S 8 Clamping Area S 4 Note 1 The certified mounting method is bolting method by VDE 2 The Mounting method has been qualified by Hyundai Heavy Indust...

Reviews: