Electrical Characteristics : HiS-MxxxRG(TG) (Poly-Crystalline Si Type, 3/4 Bus Bar Type, 60 Cells) 

Item 

HiS-MxxxRG(TG) (xxx;Maximum Power Value) 

Maximum Power at STC(Pmax) [W] 

235 

240 

245 

250 

255 

260 

265 

270 

275 

280 

285 

Voltage at Pmax (Vmpp) [V] 

30.5 

30.6 

30.7 

30.9 

31.0 

31.1 

31.3 

31.4 

31.5 

31.7 

31.8 

Current at Pmax (Impp) [A] 

7.8 

7.9 

8.0 

8.1 

8.2 

8.4 

8.5 

8.6 

8.7 

8.8 

9.0 

Open circuit voltage (Voc) [V] 

37.1 

37.1 

37.3 

37.4 

37.6 

37.7 

37.9 

38.0 

38.2 

38.3 

38.5 

Short circuit current (Isc) [A] 

8.3 

8.4 

8.5 

8.7 

8.8 

8.9 

9.1 

9.2 

9.3 

9.4 

9.5 

Module efficiency [%] 

14.4 

14.7 

15.0 

15.3 

15.6 

15.9 

16.2 

16.5 

16.8 

17.1 

17.4 

Maximum Series Fuse Rating [A] 

15 

Temp. coefficient of Pmpp [%/K] 

-0.41 

Temp. coefficient of Voc [%/K] 

-0.31 

Temp. coefficient of Isc [%/K] 

0.039 

Output tolerance [%] 

+3/-0 

Maximum system voltage [Vdc] 

IEC: 1,000 / UL: 600 or 1,000 or 1,500 

Cell quantity in series [pcs] 

60 

Bypass diodes [pcs] 

Cell Type 

Poly-crystalline Silicon Cell 

Application & Safety Class 

Class A & Class II 

Fire rating 

Class C(IEC) / Type 1 or Type 2(UL) 

 

·

 

Electrical Characteristics : HiS-SxxxRG(TG) (Mono-Crystalline Si Type, 3/4 Bus Bar Type, 60 Cells) 

Item 

HiS-SxxxRG(TG) (xxx;Maximum Power Value) 

Maximum Power at STC(Pmax) [W] 

265 

270 

275 

280 

285 

290 

295 

300 

305 

310 

315 

Voltage at Pmax (Vmpp) [V] 

31.3 

31.4 

31.6 

31.7 

31.8 

32.0 

32.1 

32.3 

32.4 

32.5 

32.7 

Current at Pmax (Impp) [A] 

8.5 

8.6 

8.7 

8.8 

8.9 

9.1 

9.2 

9.3 

9.4 

9.5 

9.7 

Open circuit voltage (Voc) [V] 

38.1 

38.2 

38.4 

38.5 

38.7 

38.8 

39.0 

39.1 

39.2 

39.4 

39.5 

Short circuit current (Isc) [A] 

9.0 

9.2 

9.3 

9.4 

9.5 

9.7 

9.8 

9.9 

10.0 

10.2 

10.3 

Module efficiency [%] 

16.2 

16.5 

16.8 

17.1 

17.4 

17.7 

18.0 

18.3 

18.6 

18.9 

19.2 

Maximum Series Fuse Rating [A] 

15 

20 

Temp. coefficient of Pmpp [%/K] 

-0.40 

Temp. coefficient of Voc [%/K] 

-0.29 

Temp. coefficient of Isc [%/K] 

0.039 

Output tolerance [%] 

+3/-0 

Maximum system voltage [Vdc] 

IEC: 1,000 / UL: 600 or 1,000 or 1,500 

Cell quantity in series [pcs] 

60 

Bypass diodes [pcs] 

Cell Type 

Mono-crystalline Silicon Cell 

Application & Safety Class 

Class A & Class II 

Fire rating 

Class C(IEC) / Type 1 or Type 2(UL) 

 
 

 

Summary of Contents for HIS-M210RF

Page 1: ...gions may have different regulations for solar PV installations In this manual hereafter IEC only is used to refer to regions where IEC standard applies e g Europe Middle East most of Asia Pacific countries UL only is used to refer to regions where UL standard applies e g United States Canada all other references are global 2 General Information This manual provides the installation information fo...

Page 2: ...ule generates over DC 30V which is potentially hazardous Modules are heavy Be sure to have more than two persons with anti slip gloves on carry each PV module Do not throw and drop PV modules Do not sit stand step walk and or jump on the module including the frames Do not drop or place objects on the modules Do not place excessive loads on the modules or twist the module frame All installation equ...

Page 3: ...on Do not use different types of PV module in a same module array Abide by the safety regulations for all other components within the total system 2 7 UL Listing Information The following requirements should be considered carefully during installation to meet UL requirements It is necessary to use single or non hollowed copper wire For module connection it is necessary to use irradiation proof cab...

Page 4: ...turally disappear over time or can be reduced by following the washing guidelines in Section 7 1 Do not install PV modules horizontally Horizontal installation can cause performance drop of PV modules HHIGE recommends mounting modules at a 12 5 tilt or greater 3 3 General Operation Condition PV modules will be operated under General Operation Condition GOC Do not install PV module at site beyond G...

Page 5: ...stalled in sulfurous area near sulfurous volcano and sulfurous spring If PV modules are installed near factory or plant area they can be polluted by fumes and the pollution may not be cleaned Thus the installer should consider and check the installation area and the distance from factory or plant area If PV modules are installed in damp environments the installer should check the installation area...

Page 6: ...2 Korea 1100 430 252 948 652 4 x Ø 7 L11 MOUNTING HOLES GROUND MARK 4x Ø4 2 GROUND HOLES 185 20 145 20 1200mm 4mm CABLE AND CONNECTOR 1200mm 4mm CABLE AND CONNECTOR 2 J BOX L A B E L MOUNTING HOLE MOUNTING HOLE MOUNTING HOLE 430 GROUND HOLE GROUND HOLE GROUND HOLE 10 4 Ø 7 SLOT THRU 11 7 DETAIL A Picture 2 HiS SxxxRI TI MxxxRI TI Hole Position Picture 3 Installation Method using bolt nut ...

Page 7: ...s Office Bundang First Tower 55 Bundang ro Jongno gu Seongnam si Gyeonggi do 13591 Korea Factory 313 Soi ro Soi myeon Eumseong gun Chungcheongbuk do 369 872 Korea Picture 4 Mounting Hardware Picture 5 Installation Method using clamping ...

Page 8: ...1 000 or 1 500 Cell quantity in series pcs 54 Bypass diodes pcs 3 Cell Type Poly crystalline Silicon Cell Application Safety Class Class A Class II Fire rating Class C IEC Type 1 or Type 2 UL Electrical Characteristics HiS SxxxRF TF Mono Crystalline Si Type 3 4 Bus Bar Type 54 Cells Item HiS SxxxRF TF xxx Maximum Power Value Maximum Power at STC Pmax W 225 230 235 240 245 250 255 260 265 270 275 2...

Page 9: ...0 or 1 000 or 1 500 Cell quantity in series pcs 60 Bypass diodes pcs 3 Cell Type Poly crystalline Silicon Cell Application Safety Class Class A Class II Fire rating Class C IEC Type 1 or Type 2 UL Electrical Characteristics HiS SxxxRG TG Mono Crystalline Si Type 3 4 Bus Bar Type 60 Cells Item HiS SxxxRG TG xxx Maximum Power Value Maximum Power at STC Pmax W 265 270 275 280 285 290 295 300 305 310 ...

Page 10: ...00 or 1 000 or 1 500 Cell quantity in series pcs 72 Bypass diodes pcs 3 Cell Type Poly crystalline Silicon Cell Application Safety Class Class A Class II Fire rating Class C IEC Type 1 or Type 2 UL Electrical Characteristics HiS SxxxRI TI Mono Crystalline Si Type 3 4 Bus Bar Type 72 Cells Item HiS SxxxRI TI xxx Maximum Power Value Maximum Power at STC Pmax W 325 330 335 340 345 350 355 360 365 370...

Page 11: ... Width mm inches 998 39 3 2 0 Depth mm inches 50 1 97 40 1 57 0 3 Weight kg pounds 23 2 51 1 23 0 50 7 The specifications in the datasheet are tested under STC Under actual field conditions a photovoltaic module is likely to experience conditions that produce more current and or voltage than reported at standard test conditions There are different standards of electric safety HHIGE recommend that ...

Page 12: ...g should be connected safely in order to prevent any hazard All PV modules for one serial connection must be identical in terms of output and in types Do not connect PV modules directly in parallel without the combine box 5 2 Module Wiring System voltage should not exceed the maximum system voltage of module Refer to the table of clause 4 1 Notes on specification The maximum number of modules in p...

Page 13: ...d the like have not been evaluated for electrical conductivity or for use as grounding devices and should be used only for maintaining mechanical connections and holding electrical grounding devices in the proper position for electrical conductivity Such device where supplied with the module and evaluated through the requirements in UL 1703 may be used for grounding connections in accordance with ...

Page 14: ...ushed on the direct exit of the cable screw joint A minimum bending radius R 5 x cable diameter must be maintained The cable must be routed in a way that tensile stress on the conductor or connections is prevented Picture 8 Cable Routing 5 When connect connectors insert connector until locking hook catches the holder and clicks Pull each connector gently and make sure connectors are not disconnect...

Page 15: ... sufficient to keep the module glass surface clean For AR coating HHIGE modules utilize special materials to increase energy harvest Always use clean gloves when handling the module never touch the glass with bare hands If dirt build up becomes excessive clean the glass surface with room temperature water Do not use water with high pressure for cleaning Do not use harsh cleaning materials such as ...

Page 16: ...0 160 20 1000mm 4mm CABLE AND CONNECTOR 2 1000mm 4mm CABLE AND CONNECTOR 2 MOUNTING HOLES 2 MOUNTING HOLES 2 MOUNTING HOLES 47 325 4 x Ø 4 2 GROUND HOLES J BOX 35 0 3 30 SECTION D D 30 35 11 7 5 11 35 11 DETAIL B 8 8 Ø 7 SLOT THRU DETAIL A SECTION C C 11 800 60 360 253 954 548 8 x Ø 7 L11 MOUNTING HOLES GROUND MARK C C D D A 200 20 160 20 998 2 0 1640 2 0 420 20 J BOX 4 x Ø 4 2 GROUND HOLES GROUND...

Page 17: ... AND CONNECTOR 2 MOUNTING HOLE MOUNTING HOLE MOUNTING HOLE J BOX L A B E L 430 GROUND HOLE GROUND HOLE GROUND HOLE 50 0 3 430 20 998 2 0 1960 2 0 B 1960 2 0 998 2 0 10 4 Ø 7 SLOT THRU DETAIL B DETAIL A 35 0 50 0 SECTION C C SECTION D D 11 0 35 0 50 0 11 0 6 5 10 11 7 1100 430 252 948 652 4 x Ø 7 L11 MOUNTING HOLES GROUND MARK 4x Ø4 2 GROUND HOLES C C D D 185 20 145 20 1200mm 4mm CABLE AND CONNECTO...

Page 18: ...IS M SxxxRI TI Method 2400 Pa 5400 Pa Bolting Long Bar Clamping Clamping area Additional support bar area Additional Clamping area for slipping snow Min clamping width 2 50mm Long Bar Clamping Area L 4 L 8 Clamping Area L 4 Short Bar Clamping Area S 4 S 8 Clamping Area S 4 Note 1 The certified mounting method is bolting method by VDE 2 The Mounting method has been qualified by Hyundai Heavy Indust...