1speed
2speed
3speed
4speed 5speed
6speed
7speed
0speed
Frequency command from
operator or analog external
input terminal
SF1
SF2
SF3
SF4
FW
1speed
SF5
SF6
SF7
Multi-
speed
SF7
SF6
SF5
SF4
SF3
0 speed
1 speed
2
3
4
5
6
7
speed
speed
speed
speed
speed
speed
SF1
SF2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
(2) Bit operation
It is possible to set multi-speed 0 to 7 by assigning 32 to 38 (SF1-SF7) to the intelligent input terminals.
Set frequency SF1-SF7 to A021-A027.
When each terminal turns ON simultaneously, the lower number has priority.
In order for the inverter to operate both the frequency and the RUN operation (FW, RV) must be applied.
N300 INSTRUCTION MANUAL
Chapter 4 Explanation of function