SECTION 7 - MAINTENANCE

Proper maintenance is important in order to ensure safe, economical, and 
trouble-free operation.    Improper maintenance may cause the air compressor 
to malfunction and can lead to serious injuries or death.

Shut off the compressor before performing any maintenance.  
When the engine is running, make sure the area is 
well ventilated.  The compressed air may contain harmful 
vapours or particles.

Use authorized parts or their equivalent.  The use of replace-
ment parts which are not equivalent quality may damage the 
compressor.

NOTE: Some of these maintenance techniques can be danger-
ous and must be performed by a qualified technician.

In order to maintain high performance and extend the service life of the com-
pressor, periodical inspection and adjustments should be done based on the 
following maintenance schedule:

PROCEDURES

DAILY OR 

BEFORE 

EACH USE

AFTER 

EACH USE

OTHER

General Inspection

X

Drain condensation in 

tank(s)

X

Check for unusual 

noise/vibration

X

Check for air leaks

X

Check safety relief 

valve

X

Inspect air filter, replace 

if necessary

Approx. every 

100 hours

Clean exterior of 

compressor

X

Summary of Contents for HHC2G

Page 1: ......

Page 2: ...HHC4GAC_UG_EN_0214 2014 MIDLAND POWER INC...

Page 3: ...information in this publication is based on the latest product information available at the time of approval for printing No part of this publication may be reproduced without written permission If a...

Page 4: ...ts and Accessories Safety 1 6 Risk of Explosion or Fire 1 7 Risk of Bursting 1 8 Risk of Electrical Shock 1 9 Risk to Breathing 1 10 Risk of Burn 1 11 Risk of Falling 1 12 Risk of Moving Parts 2 Speci...

Page 5: ...trical shock 2 Turn off the air compressor immediately if the device begins to operate abnormally Then disconnect the device and investigate the problem 1 3 MAINTENANCE SAFETY 1 Turn off the air compr...

Page 6: ...or at least 20 feet away when spray ing flammable materials 3 Keep all flammable materials in a secure location away from the air compressor 4 Do not restrict any of the compressor s ventilation openi...

Page 7: ...after use of the compressor The compressor will remain hot for several minutes after it has been shutdown 2 Do not move the unit while the compressor is running 1 11 RISK OF FALLING 1 Make sure that t...

Page 8: ...exceeds the maximum pressure rating Check Valve This valve closes when the pump is not in operation in order to retain air pressure in the tank Tank Pressure Gauge Indicates the reserve air pressure i...

Page 9: ...9 HHC4G User Manual Allows for easy attachment and removal of the air hose Motor Thermal Overload Protector If the motor begins to overheat this protector will shut off the motor SECTION 4 DIAGRAMS...

Page 10: ...ARTS LIST 71 73 72 67 41 40 38 37 53 52 51 50 47 54 55 56 57 58 64 65 62 63 66 61 28 25 24 23 22 13 12 18 11 10 14 17 16 32 33 29 7 9 8 8 7 6 5 3 4 2 1 30 31 34 35 43 44 45 49 46 47 42 48 36 15 20 21...

Page 11: ...6 Left Shroud 11 Cylinder 37 Right Shroud 12 Tooth Washer 38 Bolt ST4 2x16 13 Nut M8 39 Bolt M5x16 14 Running Capacitor 40 Washer 15 Starting Capacitor 41 Bolt ST4 2x25 16 Screw M3x6 42 Regulator 17 W...

Page 12: ...t M8x30 65 Rubber Feet 55 Washer 66 Screw M5 12 56 Spring Washer 67 Drain Valve 57 Nut M8 68 Power Plug 58 Check Valve 69 Terminal 1 59 Exhaust Pipe 70 Terminal 2 60 Nut G3 8 71 O Ring 61 Gasket 72 Sc...

Page 13: ...ROCEDURE The following instructions should be followed before the first time the compres sor is operated in order to optimize the life of the compressor and to help prevent any damage to the unit 1 Ma...

Page 14: ...ve the attached hose and accessory 5 Drain all air and water from the air tank 6 Once the tank is fully drained close the drain valve 7 Store in a safe dry non freezing area STORAGE 1 Do not store the...

Page 15: ...The use of replace ment parts which are not equivalent quality may damage the compressor NOTE Some of these maintenance techniques can be danger ous and must be performed by a qualified technician In...

Page 16: ...EACH USE OTHER Oil exposed metal and moving parts X NOTICE 1 Service more frequently when used in dusty areas 2 Should be serviced by an authorized service dealer 3 Must be serviced by an authorized...

Page 17: ...ons Overheated motor Check for cause and replace or reset Check wiring con nections Use reset button Wait for automatic reset Compressor does not supply enough pressure to operate Air leak in safety v...

Page 18: ...ibra tion during operation Check valve is loose or broken Defective motor or pump Clean or replace check valve Contact Hyundai Power Customer Service Excessive starting and stopping Hose hose connec t...

Page 19: ...ure point at which the motor shuts off automatically Cycle The series of steps that a compressor performs Cycle Time The amount of time for a compressor to complete one cycle HP Horsepower required at...

Page 20: ...ing normal business hours All repaired and replacement parts shall be warranted for 90 days after the initial date of installation or purchase Limitations of Remedies and Disclaimers THE FOREGOING LIM...

Page 21: ...to published specifications 7 Items not supplied by Hyundai such as but not limited to external wiring filters etc 8 Repairs made during the warranty period without first obtaining a case number from...

Page 22: ...22 HHC4G User Manual To obtain warranty service contact our customer support center Toll Free 1 877 528 3772 E mail support Hyundaipower ca Website www Hyundaipower ca...

Page 23: ...23 HHC4G User Manual...

Reviews: