4.2 - Priming Water
Make sure to prime the pump with water prior to operating it. Priming creates
a vacuum that helps to start the flow of water.
1. Unscrew the primer cap and insert the neck of the water container into
the opening. Gradually tilt until the reservoir is full.
2. Tighten the cap back on.
3. In case of dry operation (running the pump without priming), stop the
engine immediately and allow it to cool before following the priming
procedure.
Do not operate without priming. Doing so will overheat the engine and result
in damage to the system. Ensure that the priming water does not contain
debris.
4.3 - Starting the Trash Pump
RECOIL START METHOD
1. Rotate the fuel valve lever to ON position.
2. If the engine is cold: Push the choke lever to the CLOSE position out to
close the choke.