10.
Electric ceiling heater
EN
ATTENTION!
The power outlet should be rated at least 10A for models with a
maximum capacity of up to 1800 W and at least 16A for models with
a maximum capacity of more than 1800 W.
5. CONNECTING TO THE MAINS
1. The heater is designed for connection to the single-phase ~220 V, 50 Hz electric mains equipped
with a grounding loop.
2. Before connection, make sure that speciications of the electric mains at the connection point
meet the parameters indicated on the appliance nameplate.
3. The electric mains should be equipped with an automatic circuit breaker with rated current not
less than 16A
4. For connection of the heater to the electric mains, it is necessary to do the following:
• remove the cover from the heater, cut a hole in the rubber seal, insert the electric cable to the
heater, tightly ix the bare ends of the electric cable in the junction block of the heater with screws
in strict correspondence with marking on the block, reinstall the cover.
NOTE:
The instruction manual for remote control block is not included in
the scope of delivery. Should be bought separately.
ATTENTION!
Ater installation of the heater and before switching for the irst time,
it is necessary to wipe the radiating board with alcohol. Ater that, it is
PROHIBITED to touch the radiating board.
NOTE:
1. Depending on material and design of ceiling structural elements,
the heater is secured onto appropriate fasteners chosen on basis
of the strength condition. Strength of the ceiling or structural
elements, to which the heater is secured, should be suicient to
endure 5-fold weight of the heater.
2. The heater can be installed on the wall and mounted on the height
not less than 1.8 from the loor. Also it is obligatory to be installed
an additional protection in order to avoid the contact with heating
plates.