background image

 

IM2021 

29 

 

Do  not  discard  water  tank  magnets  and  plastic  rivets.  Otherwise,  the  machine  will  not 
automatically  stop  working  when  the  water  tank  is  full,  and  the  condensed  water  will  overflow 
and damage the floor of the room. 

  

 

Please  be  sure  to  clean  the  condensed  water  in  the  water  tank  before  resetting  the  working 
mode of the machine. 
If the water tank is dirty, rinse it with clean water. Avoid using detergents, steel balls, chemical 
dust removers, diesel oil, benzene, diluents or other solvents. Otherwise, the water tank will be 
damaged and leak 
Replace  the  empty  tank  back  into  the  unit.  Otherwise,  the  water  full  indicator  may  remain  red 
and the machine cannot restart. 

 

CONTINUOUS DRAINING 

For  continuous  operation  or  unattended  dehumidification,  please  connect  the  attached  drain 
hose to the unit. Condensate water can be automatically flow into a bucket or drain by gravity. 
1.Straighten the drainage pipe 
2.Insert one end of the drain into the drain into the cistern hole and connect the other end to the 
bathroom, outdoor or bucket like container, or the prescribed drainage area. 

 

 

WARNING 

 
Please do not block the drain or drain pipe, if the phenomenon of blocking, condensed water will 
flow into the water tank. 
Please do not bend the drain pipe. The height of the drain pipe should be lower than the outlet. 
The drain pipe shall be securely connected to the outlet; 

 

11.  MAINTENANCE 

Note: before cleaning and maintaining the machine, be sure to turn off the machine and pull the 
power plug to prevent electric shock. 
 

CLEANING THE AIR FILTER (every two weeks) 

Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of 
the system and if it becomes blocked it can cause damage to the unit.  

Summary of Contents for H-DH20-P83WF

Page 1: ...INSTRUCTION MANUAL ELECTRIC DEHUMIDIFIER H DH25 P84WF H DH20 P83WF...

Page 2: ...IM2021 2 1 2 1 R290 2 3 4 5 6 7 8 8...

Page 3: ...IM2021 3 9 10 11 12 13 0 C 2 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 4 2 29 30 31 32 33 34 35 36...

Page 4: ...IM2021 4 37 38 39 40 41 42 43 44 20 45 46 3 4 1 1 H DH25 P84WF H DH20 P83WF 25 20 6 5 6 5 380 370 220 240 50 220 240 50 2 2 2 2 3 130 130 45 45 R290 R290 Class I Class I...

Page 5: ...IM2021 5 75 58 0 7 3 2 0 7 3 2 5 35 5 35 2 20 30 20 30 14 5 14 16 15 5 500x340x240 500x340x240 5 1 2 3 4 5 6 7 8 9 10 11 12 13 1...

Page 6: ...IM2021 6 6 4 2 30 5 41 F 2 5 41 F 35 95 F 220 240 50...

Page 7: ...IM2021 7 7 1 1 2 1 3 1 4 1 8 50 30 3 3...

Page 8: ...IM2021 8 10 57 RH 63 RH 600 5 30 80 0 24 1 1 00...

Page 9: ...IM2021 9 5 1 5 1 45 45 65 65 E0 E2 CL CH LO HI 9 WI FI Wi Fi Smart Life Android iOS 4G Wi Fi iOS 8 0 Android 4 4 2 4 Smart Life QR code Smart Life...

Page 10: ...IM2021 10 5 Wi Fi Wi Fi AP Wi Fi SmartLife XXXX Wi Fi 5 Wi Fi 1 Wi Fi SmartLife XXXX 2 10 Wi Fi 10 Wi Fi Wi Fi 10 10 1 2...

Page 11: ...IM2021 11 3 4 5 6 7...

Page 12: ...IM2021 12 1 2 11 1...

Page 13: ...IM2021 13 2 3 12 1 2 3 4 13 1 2 3...

Page 14: ...IM2021 14 4 CO2 5 6 7 8...

Page 15: ...IM2021 15 9 10 11 12 13...

Page 16: ...IM2021 16 OFN 14 OFN OFN OFN 15 OFN 16...

Page 17: ...IM2021 17 a b c d e f g 80 h i j 17 18...

Page 18: ...IM2021 18 14 2 2 5 C 35 C E2 LO 20 HI 90 CL 5 CH 38 15...

Page 19: ...IM2021 19...

Page 20: ...ions can result in damage to the health of the user and other people as well as damage to their property 1 The unit is designed only for use with R 290 propane gas as the designated refrigerant 2 Plea...

Page 21: ...and store the device in a room with an area of more than 4 m 2 29 Store the device in a well ventilated place The non ventilated area where the device is installed shall be arranged in such a way tha...

Page 22: ...20 Volume of the tank l 6 5 6 5 Rated power consumption W 380 370 Power Options V Hz 220 240 50 220 240 50 Rated current 2 2 2 2 Air consumption m 3 h 130 130 Noise level Internal External Split dB 4...

Page 23: ...he actual instrument 6 INSTALLATION WARNING Install the unit in rooms which exceed 4 m Do not install the unit in a place where inflammable gas may leak Do not use in the outdoors This dehumidifier is...

Page 24: ...elected when the unit was last used Check the device after unpacking for any damages or scratches on it Select a suitable location making sure that there is easy access to an electrical outlet Connect...

Page 25: ...wn Both fan speed and humidity can be adjusted under auto mode Continuously drying mode The machine continues to run but the humidity can not be adjusted Press the sleep button the indicator lights up...

Page 26: ...ime it will be display the ambient temperature Press this key to set the timer function of 0 24 hours The interval is 1 hour Each time you press this button the value increased 1 hours and then the co...

Page 27: ...ht show Green Ambient Humidity 65 The light show Red If the LED display E0 E2 CL CH LO HI the light will show red 9 INFORMATION ON THE APP SMART LIFE The Smart Life app is available for android and iO...

Page 28: ...e appliance using the app 8 Press and hold the Timer button for about 5 seconds the appliance disconnect the WIFI lamp lights off TROUBLE SHOOTING Network connection failed Solution Network connection...

Page 29: ...e attached drain hose to the unit Condensate water can be automatically flow into a bucket or drain by gravity 1 Straighten the drainage pipe 2 Insert one end of the drain into the drain into the cist...

Page 30: ...time more than a few weeks it is best to clean the unit and dry it out completely Please store the unit per the following steps 1 Press power button to switch off and unplug the unit 2 Drain the remai...

Page 31: ...n the refrigeration equipment or any associated parts appropriate fire extinguishing equipment shall be available to hand Have a dry powder orCO2 fire extinguisher adjacent to the charging area 5 No i...

Page 32: ...in order to warn of a potentially dangerous situation Pay particular attention to ensure the impossibility to change damage deform the housing when working with electrical components in such a way as...

Page 33: ...d continuing to fill it until reaching the operating pressure then release it into the atmosphere and then vacuum it again This process shall be repeated until the complete absence of the cooling agen...

Page 34: ...d have the marking appropriate for this type of cooling agent i e special cylinders for the cooling agent extraction The cylinders shall be equipped with a pressure relief valve and corresponding shut...

Page 35: ...e with the laws rules and methods in region of recycling Detailed information about the recycling of the device you can receive from a representative of the local authorities after providing full info...

Page 36: ...www hyundai home ru Manufactured Distributed by Home Electronics Limited China Licensed by Hyundai Corporation Holdings Korea Made in China...

Reviews: