background image

 

IM2021 

31 

 

13.  SAFETY PRECAUTIONS ON SERVICING 

 - Read the technical manual 

 

ATTENTION! 

Any person involved in service work on the device or intervention in the refrigerant circuit must 
go through special training, confirmed by a certificate.

 

Please follow these warnings when to undertake the following when servicing a dehumidifier with 
R290. 

1. 

Checks to the area 

Prior  to  beginning  work  on  systems  containing  flammable  refrigerants,  safety  checks  are 
necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating  system, 
the following precautions shall be complied with prior to conducting work on the system. 

Work procedure 

Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable 
gas or vapor being present while the work is being performed. 

2. 

General work area 

All  maintenance  staff  and  others  working  in  the  local  area  shall  be  instructed  on  the  nature  of 
work  being  carried  out.  Work  in  confined  spaces  shall  be  avoided.  The  area  around  the 
workspace  shall  be  sectioned  off.  Ensure  that  the  conditions  within  the  area  have  been  made 
safe by control of flammable material. 

3. 

Checking for presence of refrigerant 

The  area  shall be checked  with  an  appropriate  refrigerant  detector  prior  to  and  during  work,  to 
ensure  the  technician  is  aware  of  potentially  flammable  atmospheres.  Ensure  that  the  leak 
detection equipment being used is suitable for use with flammable refrigerants, i.e. no sparking, 
adequately sealed or intrinsically safe. 

4. 

Presence of fire extinguisher 

If  any  hot  work  is  to  be  conducted  on  the  refrigeration  equipment  or  any  associated  parts, 
appropriate  fire  extinguishing  equipment  shall  be  available  to  hand.  Have  a  dry  powder 
orCO2 fire extinguisher adjacent to the charging area. 

5. 

No ignition sources 

No  person  carrying  out  work  in  relation  to  a  refrigeration  system  which  involves  exposing  any 
pipe work that contains or has contained flammable refrigerant shall use any sources of ignition 
in  such  a  manner  that  it  may  lead  to  the  risk  of  fire  or  explosion.  All  possible  ignition  sources, 
including  cigarette  smoking,  should  be  kept  sufficiently  far  away  from  the  site  of  installation, 
repairing, removing and disposal, during which flammable refrigerant can possibly be released to 
the  surrounding  space.  Prior  to  work  taking  place,  the  area  around  the  equipment  is  to  be 
surveyed to make sure that there are no flammable hazards or ignition risks. 

“No Smoking” signs 

shall be displayed. 

6. 

Ventilated area 

Ensure  that  the  area  is  in  the  open  or  that  it  is  adequately  ventilated  before  breaking  into  the 
system or conducting any hot work. A degree of ventilation shall continue during the period that 
the  work  is  carried  out.  The  ventilation  should  safely  disperse  any  released  refrigerant  and 
preferably expel it externally into the atmosphere. 

7. 

Checks to the refrigeration equipment 

Where  electrical  components  are  being  changed,  they  shall  be  fit  for  the  purpose  and  to  the 

correct specification. At all times the manufacturer’s maintenance and service guidelines shall be 
followed. If in doubt consult the man

ufacturer’s technical department for assistance. 

The following checks shall be applied to installations using flammable refrigerants: 

–  The  charge  size  is  in  accordance  with  the  room  size  within  which  the  refrigerant  containing 
parts are installed; 

– The ventilation machinery and outlets are operating adequately and are not obstructed; 

– If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the 
presence of refrigerant; 

Summary of Contents for H-DH16-P82WF

Page 1: ...INSTRUCTION MANUAL ELECTRIC DEHUMIDIFIER H DH16 P82WF...

Page 2: ...IM2021 2 1 2 1 R290 2 3 4 5 6 7 8 8...

Page 3: ...IM2021 3 9 10 11 12 13 0 C 2 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 4 2 29 30 31 32 33 34 35 36...

Page 4: ...IM2021 4 37 38 39 40 41 42 43 44 20 45 46 3 4 1 1 H DH16 P82WF 16 2 270 220 240 50 1 4 3 110 38 R290 Class I...

Page 5: ...IM2021 5 50 0 7 3 2 5 35 2 20 30 12 13 280x200x500 5 1 2 3 4 5 6 7 8 9 10 11 12 13 1...

Page 6: ...IM2021 6 6 4 2 20 5 41 F 2...

Page 7: ...IM2021 7 5 41 F 35 95 F 220 240 50 7 1 1 2 1 3 1 4 1 8 30...

Page 8: ...IM2021 8 3 3 30 to 35 40 45 50 55 60 65 70 75 80 30 3 0 24 1 1 00...

Page 9: ...IM2021 9 57 30 63 9 WI FI Wi Fi Smart Life Android iOS 4G Wi Fi iOS 8 0 Android 4 4 2 4 Smart Life...

Page 10: ...IM2021 10 QR code Smart Life 5 Wi Fi Wi Fi AP Wi Fi SmartLife XXXX Wi Fi 5 Wi Fi 1 Wi Fi SmartLife XXXX 2 10 Wi Fi 10 Wi Fi Wi Fi 10...

Page 11: ...IM2021 11 10 1 2 3 4 5 6 7...

Page 12: ...IM2021 12 1 2 11 1...

Page 13: ...IM2021 13 2 3 4 12 1 2 3 4 13...

Page 14: ...IM2021 14 1 2 3 4 CO2 5 6...

Page 15: ...IM2021 15 7 8 9 10...

Page 16: ...IM2021 16 11 12 13 OFN 14 OFN OFN OFN...

Page 17: ...IM2021 17 15 OFN 16 a b c d e f g 80 h i j 17 18...

Page 18: ...IM2021 18 14 2 2 5 C 35 C...

Page 19: ...IM2021 19 E2 LO 20 HI 90 CL 5 CH 38 15...

Page 20: ...ety precautions must be observed Improper operation by ignoring safety precautions can result in damage to the health of the user and other people as well as damage to their property 1 The unit is des...

Page 21: ...e This may cause an electric shock or damage to the device 28 Install operate and store the device in a room with an area of more than 4 m 2 29 Store the device in a well ventilated place The non vent...

Page 22: ...P82WF Dehumidification capacity l d 16 Volume of the tank l 2 Rated power consumption W 270 Power Options V Hz 220 240 50 Rated current 1 4 Air consumption m 3 h 110 Noise level Internal External Spl...

Page 23: ...al instrument 6 INSTALLATION WARNING Install the unit in rooms which exceed 4 m Do not install the unit in a place where inflammable gas may leak Do not use in the outdoors This dehumidifier is intend...

Page 24: ...elected when the unit was last used Check the device after unpacking for any damages or scratches on it Select a suitable location making sure that there is easy access to an electrical outlet Connect...

Page 25: ...mpressor starts working after 3 seconds When environmental humidity set humidity 3 the compressor stops working and fan stops working after 30 seconds delay Both fan speed and humidity can be adjusted...

Page 26: ...de Long press to turn on off the child lock function Touch the sleep button the sleep indicator will light up the mode indicator will go out and the wind speed will automatically change to low wind to...

Page 27: ...I long press the timer button for 5 Second to start the network configuration the WIFI indicator flashes slowly 6 When WIFI indicator flashes slowly select Add Device Small Home Appliances Dehumidifie...

Page 28: ...heck that the float is correctly in place WARNING Do not discard water tank magnets and plastic rivets Otherwise the machine will not automatically stop working when the water tank is full and the con...

Page 29: ...nd the drain pipe The height of the drain pipe should be lower than the outlet The drain pipe shall be securely connected to the outlet 11 MAINTENANCE Note before cleaning and maintaining the machine...

Page 30: ...power button to switch off and unplug the unit 2 Drain the remaining water from the unit Clean the filter and let the filter dry completely in a shaded area 3 Collect the power cord at the water tank...

Page 31: ...available to hand Have a dry powder orCO2 fire extinguisher adjacent to the charging area 5 No ignition sources No person carrying out work in relation to a refrigeration system which involves exposin...

Page 32: ...ssive number of connections non compliance of terminals with the original specification damage to seals improper installation of oil seals etc Make sure that the device is installed in a secure manner...

Page 33: ...of the last charge of oxygen free nitrogen OFN the system shall be reset to atmospheric pressure to ensure its operability This operation is totally necessary before soldering on the pipelines Make s...

Page 34: ...rs shall be equipped with a pressure relief valve and corresponding shut off valves in proper working condition Empty cylinders shall be vacuumed and if possible cooled prior to the start of the cooli...

Page 35: ...ing Detailed information about the recycling of the device you can receive from a representative of the local authorities after providing full information about the device The manufacturer and authori...

Page 36: ...www hyundai home ru Manufactured Distributed by Home Electronics Limited China Licensed by Hyundai Corporation Holdings Korea Made in China...

Reviews: