background image

 

IM2021 

21 

 

13.  If the prod

uct has been exposed to temperatures below 0ºC for some time it should be kept 

at room temperature for at least 2 hours before turning it on.  

14.  Do not attempt to repair, adjust or replace parts in the appliance.  Repair the malfunctioning 

appliance in the nearest service center. 

15.  Always unplug the appliance from the power supply before cleaning and when not in use. 
16.  Do not use other attachments than those supplied. 
17.  Do not pull, twist, or wrap the power cord around the appliance. 
18.  Do not cover the air vents! Make sure that the inlet and outlet air vents are clear. 
19.  Do  not  insert  foreign  objects  into  the  air  outlet  grille  of  the  dehumidifier.  This  is  very 

dangerous because of the high speed of the air fan. 

20.  In order to prevent water leakage, install the device only on a horizontal surface. 
21.  Do not install the device in the following locations: 
- in areas exposed to direct sunlight; 
- near open flame sources; 
- near other running heating devices; 
- in places exposed to splashes of water or steam. 
22.  Do not use the device in an explosive or corrosive environment. Do not store gasoline and 

other volatile flammable liquids near the dehumidifier, since it is very dangerous! 

23.  Use the device only for air dehumidification (humidity level reduction) in a residential area. 
24.  Clean the filter periodically to ensure efficient operation of the device. 
25.  Do not tilt the device to ensure reliable operation of the compressor. 
26.  Do  not  cover the  air  outlet  with  clothing.  This may  cause  the  overheat,  fire,  or damage  to 

the device. 

27.  Do  not  place  wet  clothing  on  top  of  the  device  and  do  not  allow  water  to  get  inside  the 

device. This may cause an electric shock or damage to the device. 

28.  Install, operate and store the device in a room with an area of more than 4 m

2

29.  Store  the  device  in  a  well-ventilated  place.  The  non-ventilated  area,  where  the  device  is 

installed, shall be arranged in such a way that, in case of cooling agent leakage, it does not 
stagnate, in order to prevent the risk of fire or explosion. 

30.  Do not use the device in laundry and washing rooms (or rooms used for this purpose). 
31.  Do not push your fingers or other objects into the air outlets. 
32.  Do not sit or stand on the device. 
33.  Empty the water tank according to the instructions described in this operating manual. 
34.  Do not use the device in small rooms (e.g. cabinets), as this may cause a fire. 
35.  Do not place or use the device near food, art, or scientific equipment. 
36.  Provide the condensate drain pipe with a downward slope so that the condensate can be 

removed without hindrance (with automatic condensate removal). 

37.  Provide the physical access to the electrical plug of the device. 
38.  The device shall not be transported by public transport. 
39.  The device shall be stored, excluding its possible physical damage. 
40.  Do  not  speed  up  the  defrosting  or  cleaning  process  by  any  method  other  than  those 

recommended by the manufacturer.  

41.  Avoid  storing  the  device  in  a  room  with  permanent  sources  of  ignition  (for  example,  an 

open flame, operating gas appliance, or operating electric heater). 

42.  Do not pierce or ignite. 
43.  Keep in mind that cooling agents can be odorless. 
44.  Do not block the air inlets or air outlets, as it may cause damage to the device. Provide at 

least 20 cm of free space in front of the air inlet and air outlet openings. 

45.  The  device  shall  always  be  maintained  in  accordance  with  the  manufacturer's 

recommendations. 

46.  Pictograms interpretation:  
 

 - Warning! Fire hazard/flammable materials. 

Summary of Contents for H-DH16-P82WF

Page 1: ...INSTRUCTION MANUAL ELECTRIC DEHUMIDIFIER H DH16 P82WF...

Page 2: ...IM2021 2 1 2 1 R290 2 3 4 5 6 7 8 8...

Page 3: ...IM2021 3 9 10 11 12 13 0 C 2 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 4 2 29 30 31 32 33 34 35 36...

Page 4: ...IM2021 4 37 38 39 40 41 42 43 44 20 45 46 3 4 1 1 H DH16 P82WF 16 2 270 220 240 50 1 4 3 110 38 R290 Class I...

Page 5: ...IM2021 5 50 0 7 3 2 5 35 2 20 30 12 13 280x200x500 5 1 2 3 4 5 6 7 8 9 10 11 12 13 1...

Page 6: ...IM2021 6 6 4 2 20 5 41 F 2...

Page 7: ...IM2021 7 5 41 F 35 95 F 220 240 50 7 1 1 2 1 3 1 4 1 8 30...

Page 8: ...IM2021 8 3 3 30 to 35 40 45 50 55 60 65 70 75 80 30 3 0 24 1 1 00...

Page 9: ...IM2021 9 57 30 63 9 WI FI Wi Fi Smart Life Android iOS 4G Wi Fi iOS 8 0 Android 4 4 2 4 Smart Life...

Page 10: ...IM2021 10 QR code Smart Life 5 Wi Fi Wi Fi AP Wi Fi SmartLife XXXX Wi Fi 5 Wi Fi 1 Wi Fi SmartLife XXXX 2 10 Wi Fi 10 Wi Fi Wi Fi 10...

Page 11: ...IM2021 11 10 1 2 3 4 5 6 7...

Page 12: ...IM2021 12 1 2 11 1...

Page 13: ...IM2021 13 2 3 4 12 1 2 3 4 13...

Page 14: ...IM2021 14 1 2 3 4 CO2 5 6...

Page 15: ...IM2021 15 7 8 9 10...

Page 16: ...IM2021 16 11 12 13 OFN 14 OFN OFN OFN...

Page 17: ...IM2021 17 15 OFN 16 a b c d e f g 80 h i j 17 18...

Page 18: ...IM2021 18 14 2 2 5 C 35 C...

Page 19: ...IM2021 19 E2 LO 20 HI 90 CL 5 CH 38 15...

Page 20: ...ety precautions must be observed Improper operation by ignoring safety precautions can result in damage to the health of the user and other people as well as damage to their property 1 The unit is des...

Page 21: ...e This may cause an electric shock or damage to the device 28 Install operate and store the device in a room with an area of more than 4 m 2 29 Store the device in a well ventilated place The non vent...

Page 22: ...P82WF Dehumidification capacity l d 16 Volume of the tank l 2 Rated power consumption W 270 Power Options V Hz 220 240 50 Rated current 1 4 Air consumption m 3 h 110 Noise level Internal External Spl...

Page 23: ...al instrument 6 INSTALLATION WARNING Install the unit in rooms which exceed 4 m Do not install the unit in a place where inflammable gas may leak Do not use in the outdoors This dehumidifier is intend...

Page 24: ...elected when the unit was last used Check the device after unpacking for any damages or scratches on it Select a suitable location making sure that there is easy access to an electrical outlet Connect...

Page 25: ...mpressor starts working after 3 seconds When environmental humidity set humidity 3 the compressor stops working and fan stops working after 30 seconds delay Both fan speed and humidity can be adjusted...

Page 26: ...de Long press to turn on off the child lock function Touch the sleep button the sleep indicator will light up the mode indicator will go out and the wind speed will automatically change to low wind to...

Page 27: ...I long press the timer button for 5 Second to start the network configuration the WIFI indicator flashes slowly 6 When WIFI indicator flashes slowly select Add Device Small Home Appliances Dehumidifie...

Page 28: ...heck that the float is correctly in place WARNING Do not discard water tank magnets and plastic rivets Otherwise the machine will not automatically stop working when the water tank is full and the con...

Page 29: ...nd the drain pipe The height of the drain pipe should be lower than the outlet The drain pipe shall be securely connected to the outlet 11 MAINTENANCE Note before cleaning and maintaining the machine...

Page 30: ...power button to switch off and unplug the unit 2 Drain the remaining water from the unit Clean the filter and let the filter dry completely in a shaded area 3 Collect the power cord at the water tank...

Page 31: ...available to hand Have a dry powder orCO2 fire extinguisher adjacent to the charging area 5 No ignition sources No person carrying out work in relation to a refrigeration system which involves exposin...

Page 32: ...ssive number of connections non compliance of terminals with the original specification damage to seals improper installation of oil seals etc Make sure that the device is installed in a secure manner...

Page 33: ...of the last charge of oxygen free nitrogen OFN the system shall be reset to atmospheric pressure to ensure its operability This operation is totally necessary before soldering on the pipelines Make s...

Page 34: ...rs shall be equipped with a pressure relief valve and corresponding shut off valves in proper working condition Empty cylinders shall be vacuumed and if possible cooled prior to the start of the cooli...

Page 35: ...ing Detailed information about the recycling of the device you can receive from a representative of the local authorities after providing full information about the device The manufacturer and authori...

Page 36: ...www hyundai home ru Manufactured Distributed by Home Electronics Limited China Licensed by Hyundai Corporation Holdings Korea Made in China...