Hytronik HMW25 Manual Download Page 5

Subject to change without notice.

Edition: 26 Feb. 2020      Ver. A0      Page 5/5

Detection Pattern

Ceiling mounted height(m)

6

0

6

10%

30%

75%

50%

A rotary switch is built inside the sensor for scene 
selection / fast programming. Total 16 channels 
are available:

Rotary switch preset

Rotary Switch Preset

Note: settings can also be changed by remote control 
         HRC-11. The last action controls.

0

5s

100%

Disable

1

1min

100%

2Lux

2

5min

100%

10Lux

3

5min

100%

30Lux

4

5min

100%

10Lux

5

5min

100%

30Lux

6

5min

100%

Disable

7

10min

100%

2Lux

8

10min

100%

10Lux

9

10min

100%

30Lux

A

10min

100%

Disable

B

10min

75%

30Lux

C

10min

50%

10Lux

D

30min

100%

50Lux

E

30min

100%

Disable

F

5s

100%

10%
10%
10%
10%
Disable
10%
30%
10%
10%
10%
30%
10%
10%
10%
30%
10%

2Lux

10s
5min
10min
30min
0s
+∞
+∞
10min
30min
+∞
+∞
+∞
+∞
+∞
+∞
10s

Detection 

range 

Channel

Hold-time

Stand-by 

time 

Stand-by 

dim level 

Daylight 

sensor

Additional Information / Documents

1. Regarding precautions for microwave sensor installation and operation, please kindly refer to
    www.hytronik.com/download ->knowledge ->Microwave Sensors - Precautions for Product Installation and Operation

2. Regarding Hytronik standard guarantee policy, please refer to 
    www.hytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy

Reviews: