1. Technical Specifications
Product type High bay dual sense sensor (daylight harvest)
Operating voltage 220-240VAC 50/60Hz
800W(Capacitive)
1000W(Resistive)
Power consumption < 0.5W
Detection angle 360
o
Detection area (DxH) 18 x 15m (Maximum)
Detection range 10% / 50% / 70% / 100%
Hold time 2s / 30s / 1min / 5min / 10min / 15min / 20min / 30min
Stand-by time 0s / 10s / 1min / 5min / 10min / 30min / 1h / +∞
Stand-by dimming level 10% / 20% / 30% / 50%
Daylight threshold 50 ~ 500Lux, Disable
Warming up time 30s
Operating temperature 35
o
C ~ +50
o
C
IP rating IP65
Sensor mode HF, PIR, HF+PIR, HF / PIR
3. Rotary Switch Settings
Detection
range
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
5s
1min
5min
5min
5min
5min
10min
10min
10min
10min
20min
20min
30min
30min
30min
5s
10s
5min
10min
+∞
+∞
+∞
30min
+∞
+∞
+∞
1h
+∞
+∞
+∞
+∞
10s
10%
10%
10%
10%
10%
30%
10%
10%
10%
30%
10%
30%
10%
30%
50%
10%
Disable
50Lux
50Lux
75Lux
100Lux
200Lux
50Lux
75Lux
100Lux
200Lux
100Lux
200Lux
100Lux
200Lux
400Lux
100Lux
Hold
time
Stand-by
time
Stand-by
dimming level
Daylight
threshold
A rotary switch is built inside the sensor for
scene selection / fast programming. Total of
16 channels available :
Note: settings can also be changed by remote control HRC-11. The last action controls.
HIGH BAY DUAL SENSE DAYLIGHT HARVEST SENSOR HIM32
Installation and Instruction Manual
Rotary switch preset (Please
see the location in 2. Installation)
Channel
4. Functions
4.1 Daylight Harvest (Daylight Regulating)
Daylight sensor measures the available natural light of the surrounding, calculates how much electrical
light is needed to reach the total lux expected. The demand is given to the LED driver by 1-10V signal, so
as to deliver the needed amount of electric light.
0
24
Light level
Time (hrs)
Normal Electric Light
Daylight controlled light
Energy Saving Zone
Natural light
Hold time
Stand-by time
HIM32-20190104-A1
Rated load
2. Installation
Warnings:
1. Installation of the sensor involves connecting it to the mains supply. This work must be
carried out by a specialist in accordance with electrotechnical regulations.
2. Disconnect power supply before installing.
The built-in daylight sensor can read ambient natural light and switch off the fixture automatically
whenever artificial light is unnecessary(natural light lux level exceeds daylight threshold).
Note: if the stand-by time is preset at "+∞", the fixture never switches off even when natural
light is sufficient.
4.2 Lux Off Function
Note: by pressing the “Sensor off” button on the remote control, the sensor occupancy function
is disabled. The target lux level for daylight harvest function can be adjusted by “Brig/-” buttons.
The light will flash ONCE rapidly after receiving the command from the remote controller.
Note: There is no load indication (the light will not flash) when button ON/OFF, POWER 100%
or POWER 80% is pressed.
4.3 Load Indication
5. Wiring Diagram
HIM32
Brown
LED driver
L
N
1-10V+
1-10V-
L
N
Blue
Grey
Red
Black
A. Ceiling mount
B. Screw to the Luminaire by conduit
C. Attach to the shade by clamp
Sensor module
PIR
Photocell
LED indicator
Infrared receiver
Rotary switch for programing
Cable entry
Installation rack
81.5
4.1
4.1
66.6
91.5
80.7
75
59.3
73.5
57.3
47.5
24.5
Cable entry
Sensor module
PIR
LED indicator
Infrared receiver
Rotary switch for programing
Photocell
59.6
66.6
89.9
0.825”
75
64
43.8
43
59.3
73.5
35.2
57.3
47.5
163.2
33.7
28.5
4.5
15
96.8
66.6
Ф
4.5
93.8
84.5
59.3
ぶ
29
Sensor module
PIR
LED indicator
Infrared receiver
Rotary switch for programing
Angle adjustment
Luminaire clamp
Photocell