Ambient daylight threshold [                ]

Press button    , the latest surrounding lux value overwrites previous lux value learned, and is set as the daylight threshold. This feature enables the fixture 
to function well in any environment.

Detection range [             ]

Press buttons in zone   to set detection range at 100% / 50% / 10%.

Hold time [             ]

Press buttons in zone   to set hold time at 30s / 1min / 5min / 10min / 30min.

Stand-by period [             ]

3UHVVEXWWRQVLQ]RQHWRVHWWKHVWDQGE\SHULRGDWVVPLQPLQPLQ’
1RWH³V´PHDQVRQRIIFRQWURO³’

” means bi-leve of dimming control, the light will never switch off. 

(i.e. the light remains at the stand-by dimming level until motion is detected.)

Stand-by dimming level [             ]

Press  buttons in zone   to set the stand-by dimming level at 10% / 20% / 30% .

Daylight sensor [             ]

Press  buttons in zone     to set daylight sensor at 2lux / 10lux / 50lux.

10

6

Press button    ,the sensor goes to manual override or semi-auto function.

15

11

13

12

7

button

10  

Power output [                ]

Press button    , the output shifts between 80% and 100%, for energy saving purposes.

5

button

5  

Dim +/- [                ]

Press button     to adjust the light brightness between 10%~100% during hold-time.“+” increases the light level, “-” will decrease the light level. 

9

button

9  

Lux disable [                ]

Press button    , the built-in daylight sensor is disabled, the light will always operate upon detection regardless of ambient light level.

14

button

14  

Manual override/ Semi-auto [                ]

Note: The buzzer beeps twice if it is in manual override mode, and beeps once if shifts to semi-auto mode.

button

15  

zone

6  

zone

11  

zone

12  

zone

zone

13 

Scene mode options [              ]

Note: the end-user can fine tune the settings by pressing buttons of detection range     / hold time    / stand-by period     / stand-by dimming level     
/daylight sensor     , the last setting will over-write that feature of the pre-set scene.

6

11

13

12

7

zone

There are 4 scene modes built into the remote control for different applications:

Scene options           Detection range               Hold time               Stand-by period           Stand-by dimming leve

Daylight sensor

SC1                         100%                               1min                           10min                                 10%

2Lux

SC2                         100%                               5min                           10min                                 10%

2Lux

SC3                         100%                               10min                          30min                                10%

10Lux

SC4                         100%                               10min                           +                                       10%

50Lux

SECTION 4 SPECIFICATION

Mains voltage

Mains current

Power factor

Operation temperature

Dimming interface 

Abnormal protection

Dimming range

Stand-by power consumption

Over-heat protection

EMC standard

Safety standard

DALI standard

Dielectric strength

IP grade

220~240VAC  50/60Hz 

•

Output voltage ( U-out max.) 

60V

  Ta: -20~+50

     Tc:+80

 

Output short-circuit protection with auto-reset 

1~30% PWM dimming;     30~100%  analogue dimming.

<0.5W

Over-heat protection with auto-reset

EN55015, EN61547, EN61000-3-2/3  

EN61347-1, EN61347-2-13,  EN60598-1    

IEC62386-102,207

Input

ĺ

output : 3750VAC  

IP20    

0.3 ~ 0.25A

25W / 500mA / 12 ~ 50V

28W / 550mA / 12 ~ 50V

30W / 600mA / 12 ~ 50V

33W / 650mA / 12 ~ 50V

35W / 700mA / 12 ~ 50V

38W / 750mA / 12 ~ 50V

40W / 800mA / 12 ~ 50V

43W / 850mA / 12 ~ 50V

45W / 900mA / 12 ~ 50V

48W / 950mA / 12 ~ 50V

50W / 1000mA / 12 ~ 50V

53W / 1050mA / 12 ~ 50V

55W / 1100mA / 12 ~ 50V

55W / 1150mA / 12 ~ 48V

55W / 1200mA / 12 ~ 46V

89%

DALI, Switch-Dim., 1-10V

Max. output 

power/current/voltage  

Max. Efficiency