Technical Specifications

Functions

1. Lux Off Function

The built-in daylight sensor can measure ambient natural light and switch off 
the fixture automatically whenever artificial light is not required (natural light 
lux level exceeds daylight threshold).

3. Zero-cross Relay Operation

Designed in the software, the sensor switches on/off the load right at the 
zero-cross point, to ensure the in-rush current is minimised, enabling the 
maximum life-time of the relay.

Product Type:
Operating Voltage:
HF System:
Transmission Power:

Detection Angle:
Detection Range(DxH):
Time Setting:
Light Control:
Mounting: 
Working Temperature:

Rated output current/voltage/power:

Tri-level Control Microwave Motion Sensor
220-240VAC 50Hz/60Hz
5.8GHz CW radar
< 0.2mW

30~150°
Max. 12 x 6m
10s ~ 30 min.
2~50 lux, disable
Indoors, Ceiling & walling mounted
-20 ~ + 60°C

Dimensions (mm)

Installation and Instruction Manual 

Integrated SensorDIM LED Driver HEC9025/I

Wiring Diagram

Super-compact sensor antenna, with Hytronik specially designed intelligent 
photocell built inside.  

Sensor antenna

Model SAM5/I

40.4

2.5 6.6

25.2

35.9

34.7

Cable side entry

24.3

15.5

2.5

25

Ф4

1.5 13

11.2

6.8

8.8

Cable back entry

Ф4.5

Infrared remote receiver

Photocell

104

53

26

4.2

110.7
119.5

LED current 

selection

LED - 

LED +


L

Antenna module

connector

Detection area

Hold-time

Stand-by dimming level

Stand-by period

Daylight threshold

2.Tri-level Control (Corridor Function)

Hytronik builds this function inside the motion sensor to achieve tri-level 
control, for some areas which require a light change notice before switch-off.  
The sensor offers 3 levels of light: 100%-->dimmed light -->off; and 2 
periods of selectable waiting time: motion hold-time and stand-by period; 
Selectable daylight threshold and freedom of detection area.  

N

L

LED  -

LED +

N

L

HEC9025/I

350mA/10-43V/15.7W    500mA/10-42V/21W

550mA/10-40V/22W    700mA/10-36V/25.2W

750mA/10-34V/25.5W    900mA/10-28V/25.2W

1. Press button    , the red LED is on for indication.
2. Press button “Sensor off”, the function of movement detection is disabled.

Sensor off [ button    ] (Daylight harvest without occupancy)

Settings

1   Detection Range

Sensor sensitivity can be adjusted by selecting 
the combination on the DIP switches to fit 
precisely for each specific application.

Note: by choosing “Sensor OFF”, it 
becomes an ordinary driver without
occupancy detection.

100%

75%
50%

Sensor OFF

1    2 

Note: “0s” means on/off control; “+∞    
”means the stand-by period is infinite and 
the light is effectively controlled by the 
daylight sensor, off when natural light is 
sufficient and automatically on at dimming 
level when insufficient.

2   Hold Time

4   Stand-by period (corridor function)

Select the DIP switch configuration for the light 
on-time after presence detection. 
This function is disabled when natural light is 
sufficient.

This is the time period you would like to keep at 
the low light output level before it is completely 
switched off in the long absence of people.

3   Daylight Threshold

Set the level according to the fixture and 
environment. The light will not turn on if ambient 
lux level exceeds the daylight threshold preset. 
Please note that the ambient lux level refers to 
internal light reaching the sensor.
Disabling the daylight sensor will put the sensor 
into occupancy detection only mode. 

2

1

50Lux
10Lux

2Lux

Disable

I

II

III
IV

3

2

1

30min

5s

30s

1min

5min

10min

20min

I

II

III

IV

V

VI

VII

0s

10s

1min

5min

10min

30min

1H

+

2  3

5   Stand-by dimming level

The setting is used to select the desired 
dimmed light level used in periods of absence 
for enhanced comfort and safety.

30%

20%

10%

50%

2

1

I

II

III
IV

Description of the Button Functions 
(remote control HRC-11) 

HRC-11

7

9

11

12

13

14

15

2

4

1

3
6
8

10

5

& A

4h

h

4 h

RESET [ button     ]

Press button     , all settings go back to the DIP switch settings.

2

2

Shift [ button      ]

Press button     , the LED on the top left corner flashes to indicate mode selection.
All values / settings in RED are in valid for 20 seconds.    

3

3

Auto Mode [ button     ]

Press button     to initiate automatic mode. The sensor starts working and all 
settings remain as before the light was switched ON/OFF. 
Note: The function of “SEMI-AUTO” is disabled.

4

4

5

3

Permanent ON/OFF [                 ]

Press button      to select permanent ON or permanent OFF mode.
* Press button     /     to resume automatic operation. 

button 

1

1

2

4

Power output [ button     ]

Press button     , the light output shifts between 80% and 100%.

6

6

Twilight  [ button 

⑤ 

]

1. Press button "Shift", the red LED is on for indication.
2. Press button "Twilight", the function of movement detection is disabled.   
    This unit is now a LED driver plus daylight sensor with daylight harvest   
    function.