Incorrect light-control setting selected

Adjust setting 

d

a

o

l

e

c

a

l

p

e

R

y

tl

u

a

f

d

a

o

L

The load will not work

 

N

O

h

c

ti

w

S

 

F

F

O

h

c

ti

w

s

s

n

i

a

M

The load is always on

Continuous movement in the detection zone

Check zone setting

The sensor is not mounted for reliably detecting

movement

Securely mount enclosure

The load is on without any identifiable

movement

Movement occurred, but not identified by the sensor

(movement behind wall, movement of small object in

immediate lamp vicinity etc.) 

Check zone setting

The load will not work despite movement  Rapid movements are being suppressed to minimise

malfunctioning or the detection radius is too small

Check zone setting

Scene mode options [              ]

Note:end-user can adjust the settings by pressing buttons of detection range     / hold time    / stand-by period     / stand-by dimming level     

/daylight sensor     , the last setting stays in validity.

6

11

13

12

7

zone

There are 4 scene modes built-in the remote control for different applications:

Scene options           Detection range               Hold time               Stand-by period           Stand-by dimming leve

Daylight sensor

SC1                         100%                               1min                           10min                                 10%

2Lux

SC2                         100%                               5min                           10min                                 10%

2Lux

SC3                         100%                               10min                          30min                                10%

10Lux

SC4                         100%                               10min                           +                                       10%

50Lux

Summary of Contents for HEC7028

Page 1: ...Daylight sensor Cut out size L x D 36 x 29 5mm Buzzer L Blue N Brown Installation hole 4 1mm Installation hole screw D x L 3 x 10mm Sensor antenna LED current selection LED LED indication Infrared remote receiver Rotary switch LED HRC 05 HEC7028 Stand by dimming level Detection range ON OFF Auto Mode Reset Power 80 Test 2s 10 20 30s 1min 100 30min 10min 5min 0s 10s 1min 30 SC1 SC2 SC3 Scene mode 1...

Page 2: ...l Detection range Hold time Daylight sensor Stand by period Stand by dimming level 0 100 5s Disable 10s 10 1 100 30s 2Lux 1min 10 2 100 1min 2Lux 5min 10 3 100 1min 10Lux 10min 10 4 100 1min Disable 10 5 100 5min 2Lux 10min 10 6 100 5min 10Lux 30min 10 7 100 5min Disable 10 8 100 10min 2Lux 10min 10 9 100 10min 10Lux 30min 10 A 100 10min Disable 10 B 50 10min Disable 30min 10 C 10 10min Disable 10...

Page 3: ...on the sensor goes to test mode hold time 2s stand by period and daylight sensor are disabled 2 Press button to quit from this mode and the sensor setting is changed accordingly Ambient daylight threshold Press button the latest surrounding lux value overwrites previous lux value learend and is set as the daylight threshold This feature enables the fixture to function well in any real application ...

Page 4: ...nd wall movement of small object in immediate lamp vicinity etc Check zone setting The load will not work despite movement Rapid movements are being suppressed to minimise malfunctioning or the detection radius is too small Check zone setting Scene mode options Note end user can adjust the settings by pressing buttons of detection range hold time stand by period stand by dimming level daylight sen...

Reviews: