background image

Instruction Manual for 

Integrated SensorDIM LED Driver 

Daylight Monitoring Version, Model No.:HEC7028

Technical Specifications

PRODUCT TYPE:

                        

Integrated sensorDIM LED driver

OPERATING VOLTAGE:          220-240VAC    50/60Hz

HF SYSTEM:                             5.8GHz CW radar

TRANSMISSION POWER:       <0.2mW

DETECTION ANGLE:               30 ~150

DETECTION RANGE:               Max. 8 meters in diameter, adjustable

TIME SETTING:                        2s, 30s~30min.

DAYLIGHT SENSOR:               2~50Lux; disable

STAND-BY PERIOD:                0s, 10s ~ +∞

STAND-BY DIMMING LEVEL: 10% ~30%

MOUNTING:                              Indoors, ceiling&wall mounted

INSTALLATION HEIGHT:         ≤5M

WORKING TEMP.:                    -20~+50

°

°

This is a smart integration of microwave motion sensor and multiple 

current selection LED driver, which gives pre-selected constant current 

to drive the LEDs to work based upon movement detection. Designed 

in the software and thanks to our worldwide patented circuit, the built-in 

daylight sensor is prior to motion sensor so as to achieve utmost energy saving purpose.

Note: the high-frequency output of this sensor is <0.2mW; approximately just 1‰ of the transmission power of a mobile telephone or

          the output of a microwave oven.

Daylight sensor

Cut-out size (L x D: 36 x 29.5mm)

Buzzer

L (Blue)

N (Brown)

Installation hole (4.1mm)

Installation hole 

(screw D x L: 3 x 10mm)

Sensor antenna

LED current selection

LED

LED indication

Infrared remote receiver

Rotary switch

LED

HRC-05

HEC7028

Stand-by dimming level

Detection range

ON/

OFF

Auto Mode

Reset

Power

80%

Test

2s

10%

20%

30s

1min

100%

30min

10min

5min

0s

10s

1min

30%

SC1

SC2

SC3

Scene mode

10min

50%

10%

30min

Hold-time

Stand-by period

5min

Lux

Disable

2Lux

10Lux

50Lux

Daylight Sensor

SC4

Power

100%

+

-

Dim

M/A

110

101.1

35.5

4.1

49.5

34.7

23.7

31.6

29

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION AND RETAIN THIS LEAFLET IN A KNOWN

AND SAFE PLACE FOR FUTURE REFERENCE.

SECTION 1 INSTALLATION AND WIRING

1.1  Ensure that the electricity supply is switched off before installing or servicing this product.
1.2  Wiring diagram

LED
LED

N

N

L

L

+

-

3rd Floor, block C, complex building, 155#, Bai'gang road south, 
Bai'gang village, Xiao Jin Kou town, Huicheng district, Huizhou 516023
Tel:86-752-2772020               F:86-752-2777877
E: [email protected]           W:www.hytronik.com

CHINA  FACTORY

Room D, 10/f, Tower A, Billion Center, 1 wang Kwong Road, 
Kowloon Bay, Kowloon, Hongkong
T: 00852-35197525               F: 00852-30116936
E: [email protected]

HYTRONIK  INDUSTRIAL  LIMITED

Summary of Contents for HEC7028

Page 1: ...Daylight sensor Cut out size L x D 36 x 29 5mm Buzzer L Blue N Brown Installation hole 4 1mm Installation hole screw D x L 3 x 10mm Sensor antenna LED current selection LED LED indication Infrared remote receiver Rotary switch LED HRC 05 HEC7028 Stand by dimming level Detection range ON OFF Auto Mode Reset Power 80 Test 2s 10 20 30s 1min 100 30min 10min 5min 0s 10s 1min 30 SC1 SC2 SC3 Scene mode 1...

Page 2: ...l Detection range Hold time Daylight sensor Stand by period Stand by dimming level 0 100 5s Disable 10s 10 1 100 30s 2Lux 1min 10 2 100 1min 2Lux 5min 10 3 100 1min 10Lux 10min 10 4 100 1min Disable 10 5 100 5min 2Lux 10min 10 6 100 5min 10Lux 30min 10 7 100 5min Disable 10 8 100 10min 2Lux 10min 10 9 100 10min 10Lux 30min 10 A 100 10min Disable 10 B 50 10min Disable 30min 10 C 10 10min Disable 10...

Page 3: ...on the sensor goes to test mode hold time 2s stand by period and daylight sensor are disabled 2 Press button to quit from this mode and the sensor setting is changed accordingly Ambient daylight threshold Press button the latest surrounding lux value overwrites previous lux value learend and is set as the daylight threshold This feature enables the fixture to function well in any real application ...

Page 4: ...nd wall movement of small object in immediate lamp vicinity etc Check zone setting The load will not work despite movement Rapid movements are being suppressed to minimise malfunctioning or the detection radius is too small Check zone setting Scene mode options Note end user can adjust the settings by pressing buttons of detection range hold time stand by period stand by dimming level daylight sen...

Reviews: