MAINTENANCE
NARROW AISLE
48
ITEM
NO.
ITEM
8 HR/
1 day
4
350 HR/
2 month
4
2000 HR
/1 year
4
PROCEDURE OR
QUANTITY
SPECIFICATION
7.
Hydraulic Oil Leaks
Hydraulic Oil Level (Full Mark)
Dipstick/Breather Cap
Hydraulic Oil Filter
Hydraulic Oil Strainer
X
X
X
C
9
C
C
C
Check for Leaks
Clean or Replace
Replace
Clean or Replace
Above 0
°
C (32
°
F)
1
Below 0
°
C
2
See Parts Manual
See Parts Manual
8.
Lift Chains
Articulating Chain Anchors
N50XMA3 -- 3 Stage Mast
X
L
L
Check for Damage
2 Lube Fittings
Engine Oil
Multi-Purpose Grease
6
9.
Mast and Carriage
Pivots, Sliding Surfaces
X
L
6
Check Operation
As Required
Multi-Purpose Grease
6
10.
Pedals, Levers, Cables, Hinges,
Linkages
L
L
As Required
As Required
Anti-Seize Lubricant
3
Anti-Seize Lubricant
3
11.
Articulation Shaft
Articulation Shaft Retaining Bolt
Articulation Shaft Ends
L
L
L
1 Lube Fitting
Multi-Purpose Grease
6
Anti-Seize Lubricant
3
Anti-Seize Lubricant
3
12.
Reach Arms -- N30/40/45XMR3
Reach Arms -- N25/30/XMDR3
Reach Cylinder Pivot Pins
Thrust Rollers -- Reach Frame
X
L
L
L
L
6 Lube Fittings
12 Lube Fittings
4 Lube Fittings
2 Lube Fittings
Multi-Purpose Grease
6
Multi-Purpose Grease
6
Multi-Purpose Grease
6
Multi-Purpose Grease
6
X = Check
C = Change
L = Lubricate
1
Hydraulic Oil, Hyster P/N 131820
6
Multi-Purpose Grease with 2-4% Molybdenum Disulfate
2
Chevron EP Hydraulic Oil 68 or equivalent
for normal operations, Hyster P/N 344117
3
Anti-Seize Lubricant, Hyster P/N 328388
7
Change after to 500 hrs. No subsequent change for life of unit
4
Whichever comes first
8 Change every 3000 hrs/3 yrs
5
Equalization Charge approx. each month, not
9 Change after first 100 hours of operation.
more than each week
NOTE: Never use steam to clean electrical parts.