4500 SRM 971
Specifications
Table 2. Operating Times N30XMXDR3, N45XMXR3, N30/40XMR2, N25XMDR2,
N30XMDR2, and N45XMR2 (Continued)
Voltage
Action
Time
24 V
16,547.4 kPa
(2400 psi)
175 Amps
Relief
36 V
16,547.4 kPa
(2400 psi)
112 Amps
No Load
24 V
7584 kPa
(1100 psi)
90 Amps
Capacity Load
24 V
7584 kPa
(1100 psi)
90 Amps
No Load
36 V
7584 kPa
(1100 psi)
60 Amps
Reach
Capacity Load
36 V
7584 kPa
(1100 psi)
60 Amps
No Load
24 V
11,721 kPa
(1700 psi)
127.5 Amps
Capacity Load
24 V
11,721 kPa
(1700 psi)
142.5 Amps
No Load
36 V
11,721 kPa
(1700 psi)
85 Amps
Retract
Capacity Load
36 V
11,032 kPa
(1600 psi)
95 Amps
No Load
24 V
9191 kPa
(1333 psi)
97.5 Amps
Capacity Load
24 V
5688 kPa
(825 psi)
81 Amps
No Load
36 V
9191 kPa
(1333 psi)
65 Amps
Tilt Forward
Capacity Load
36 V
5688 kPa
(825 psi)
54 Amps
No Load
24 V
3916 kPa
(568 psi)
73.5 Amps
Capacity Load
24 V
14,527 kPa
(2107 psi)
175.5 Amps
No Load
36 V
3916 kPa
(568 psi)
49 Amps
Tilt Backward
Capacity Load
36 V
14,527 kPa
(2107 psi)
117 Amps