© 2022 HyQuest Solutions
19
Technical Data
6
Technical Data
Technical Specifications Data Logger
Input Channels
24 channels, high-resolution
Communications
§
Remote: GPRS, 2G or optionally 3G; bi-directional
§
Local: 433 MHz, license-free ISM radio
Power Supply
§
Lithium batteries 3.6 V (up to 10 years of operation or up to 20.000 internet transfers and
200.000 data logs per unit)
§
Optional: External 12 V solar panel power supply
Data Storage
§
Internal memory for up to 250k measurement entries, non-volatile
§
Storage cycle: Freely-definable, minimum 2”
Material
and
Environmental
Conditions
§
Enclosure: stainless steel, ABS
§
Operating temperature range:
§
Modem -30 °C to +85 °C
§
Logger -40 °C to +85 °C
Dimensions: Diameter
Ø, Length, Mass
48.5 mm Ø, 411.5 mm length, 1,5 kg (without sensor)
Conformity/Complian
ce
CE
Technical Specifications Sensor
Measuring Range
§
§
Pressure: 0 - 10 mH
2
O with max. load 3 bar (further options on demand)
Resolution
Pressure 0.01 % FS; Water Temperature 0.05 °C
Material
§
Sensor: Stainless steel 316 L / 1.4435 (titanium (GR. 2) optional)
§
Seals: Viton (EPDM or Kalrez optional)
§
Cable: PUR (standard), PE (drinking water) or FEP (chemical resistant, Teflon-impregnated)
Dimensions: Diameter
Ø, Length, Mass
Typically 24 mm Ø, 157 mm length, 200 g (without cable)
Conformity/Complian
ce
CE